arXiv · 2404.07120
TEMPUS, a Timepix4-based system for event-based X-rays detection
Abstract
A readout system based on the Timepix4 ASIC, is being developed for photon science. The TEMPUS detector can be operated in two distinct modes: a photon counting mode, which allows for conventional full-frame readout at rates up to 40 kfps; and an event-driven time-stamping mode, which allows excellent time resolution in the nanosecond regime in measurements with moderate X-ray flux. In this paper, we introduce the initial prototype, a single-chip system, and present the first results obtained at PETRA III and ESRF.
Explore related subjects
Keep this discovery
Jonathan Correa, Alexandr Ignatenko, David Pennicard, Sabine Lange, Sergei Fridman, Sebastian Karl, Leon Lohse, Bjoern Senfftleben, Ilya Sergeev, Sven Velten, Deepak Prajapat, Lars Bocklage, Hubertus Bromberger, Andrey Samartsev, Aleksandr Chumakov, Rudolf Rueffer, Joachim von Zanthier, Ralf Roehlsberger, Heinz Graafsma. 2024-04-10. TEMPUS, a Timepix4-based system for event-based X-rays detection. https://arxiv.org/abs/2404.07120