SearcharxivSearch

arXiv · 2404.10471

Advances in Atom Interferometry and their Impacts on the Performance of Quantum Accelerometers On-board Future Satellite Gravity Missions

Abstract

Recent advances in cold atom interferometry have cleared the path for space applications of quantum inertial sensors, whose level of stability is expected to increase dramatically with the longer interrogation times accessible in space. In this study, a comprehensive in-orbit model is developed for a Mach-Zehnder-type cold-atom accelerometer. Performance tests are realized under different assumptions, and the impact of various sources of errors on instrument stability is evaluated. Current and future advances for space-based atom interferometry are discussed, and their impact on the performance of quantum sensors on-board satellite gravity missions is investigated in three different scenarios: state-of-the-art scenario, near-future (between the next 5 and 10 years) and far-future scenarios (between the next 10 to 20 years). We show that one can achieve a sensitivity level close to 5E-10 with the current state-of-the-art technology. We also estimate that in the near and far-future, atom interferometry in space is expected to achieve sensitivity levels of 1E-11 and 1E-12, respectively. A roadmap for improvements in atom interferometry is provided that would maximize the performance of future CAI accelerometers, considering their technical capabilities. Finally, the possibility and challenges of having ultra-sensitive atom interferometry in space for future space missions are discussed.

Explore related subjects

Keep this discovery

BibTeXRIS

Alireza HosseiniArania, Manuel Schilling, Quentin Beaufils, Annike Knabe, Benjamin Tennstedt, Alexey Kupriyanov, Steffen Schön, Franck Pereira dos Santos, Jürgen Müller. 2024-04-16. Advances in Atom Interferometry and their Impacts on the Performance of Quantum Accelerometers On-board Future Satellite Gravity Missions. https://arxiv.org/abs/2404.10471

Cite the original work for its findings. Save a collection to share your selection of sources.

KEEP EXPLORING

Related papers

High-Speed Semi-FE Readout Module for ATLAS MDT at HL-LHC: Design and Production-Level Characterization

The High-Luminosity upgrade of the Large Hadron Collider (HL-LHC) introduces increased demands on the ATLAS Muon Spectrometer, particularly in terms of data throughput, timing distribution and system reliability. The Phase-II Chamber Service Module (CSM) is a key component of the upgraded Monitored Drift Tube (MDT) trigger and readout system, providing a high-speed interface between the front-end electronics and the backend systems. This paper describes the design and implementation of the Phase-II CSM, together with its validation. The results show that the CSM supports two independent optical uplinks, each operating at a line rate of 10.24 Gbps, together with clock distribution and slow control in the expected operating environment. Integration with small-diameter MDT (sMDT) chambers and tests with the prototype L0MDT trigger system are also presented. The CSM boards are now in production and will be used for installation and integration during the upcoming LHC Long Shutdown.

physics.ins-det

Spectral Discrimination of Deposited Gamma-Ray Energies in a Simulated CeBr$_3$ Scintillator

We show that wavelength measurements of individual detected optical photons may provide additional information about gamma-ray energy deposited in a CeBr$_3$ crystal when the detected-photon-count distributions overlap for nearby gamma-ray energies. Monoenergetic 662 and 629 keV gammas are used in a Geant4 simulation of a $25\times25\times20~\mathrm{mm^3}$ CeBr$_3$ crystal. Assuming a light yield of $6.0\times10^4$ photons/MeV, a wavelength-independent photon-detection efficiency of 30%, and a wavelength resolution of $\sigma_{\lambda}=40$ nm, we find that the fraction of photons reconstructed above 385 nm gives an event-level separation of $\sim$ 2 standard deviations between the 662 and 629 keV event populations selected within the same $\sim$ 1%-wide detected-photon-count interval. No timing or reconstructed interaction-position information is used. The result demonstrates, within the present simulation model, that event-dependent optical spectra can retain energy information beyond an undifferentiated photon count.

physics.ins-det

Operation of a negative ion gas time projection chamber without electronegative fill gases

The high fidelity reconstruction of particle tracks in micropatterned gaseous time projection chambers renders this technology ideal for future rare-event searches, including direction-sensitive dark matter experiments. Large drift distances are typically required for such experiments, so that the overall spatial resolution is limited by diffusion. Negative ion drift exhibits lower diffusion than electron drift and is thus an attractive option for realising a large-scale detector. The use of electronegative gases to create negative ions introduces technical challenges, most notably a reduction in gain when compared to conventional gas mixtures. In this study, we demonstrate a new method for negative ion generation via dissociative electron attachment using the conventional molecular fill gas CF$_4$. Our optical measurements of negative ion drift indicate electron attachment lengths of $<$1 mm and comparable gain to electron avalanches. The individual negative ion avalanches were also time-resolved, allowing the number of ions reaching the readout to be counted. We measure an improved energy resolution by single ion counting, relative to an integrated electron avalanche signal measured under identical gain conditions.

physics.ins-det