Design and optimization of a hadronic calorimeter based on micropattern gaseous detectors for a future experiment at the Muon Collider
Abstract
Micro-pattern gaseous detectors (MPGDs) are a promising readout technology for hadronic calorimeters (HCAL) thanks to their good space resolution, longevity and rate capability. We describe the development of a HCAL based on MPGDs for an experiment at the proposed Muon Collider. The design of a semi-digital MPGD-HCAL is shown and its performance is calculated with Monte Carlo simulations with high-energy pions, showing an energy resolution down to 8\% for \SI{80}{\giga\eV} pions. We also present the performance of twelve MPGD prototypes with different technologies (MicroMegas, $\mu$-RWELL and RPWELL) assembled and operated in test beam first with high-energy muons and later with pions in a hadronic calorimeter prototype of $\sim1\,\lambda_\text{I}$ length; the detectors have a good response uniformity (lower than 17\%) and space resolution and their performance in the calorimeter shows very good agreement with the Monte Carlo shower calculation.
Explore related subjects
Keep this discovery
Antonello Pellecchia, Marco Buonsante, Maryna Borysova, Anna Colaleo, Maria Teresa Camerlingo, Luigi Longo, Mauro Iodice, Marcello Maggi, Luca Moleri, Raffaella Radogna, Givi Sekhniaidze, Federica Maria Simone, Anna Stamerra, Rosamaria Venditti, Piet Verwilligen, Darina Zavazieva, Angela Zaza. 2024-07-14. Design and optimization of a hadronic calorimeter based on micropattern gaseous detectors for a future experiment at the Muon Collider. https://arxiv.org/abs/2407.10261
Cite the original work for its findings. Save a collection to share your selection of sources.