Methodology of safety evaluation of In-Vessel Retention

Abstract

Molten corium stabilization following a severe accident is of crucial importance in order to ensure containment integrity on a long-term basis and minimizing radioactive elements releases outside the plant. Among the possible options, In-Vessel Retention (IVR) through external cooling appears as an attractive solution that would limit the dispersion of corium in the plant and minimize the risks of containment failure. Nevertheless its feasibility has to be proved.The IVR strategy is already adopted in Europe for some VVER 440 type 213 reactors thanks to thorough research work started in the '90s for the Finnish Loviisa power plant, and subsequently extended to Bohunice and Mochovce (Slovakia), Dukovany (Czech Republic) and Paks (Hungary) power plants. The strategy is also included in the design of some high power new Gen.III reactors such as AP1000, APR 1400 and Chinese HPR1000 and CAP1400. It has also been studied in the past for other reactor concepts like KERENA (1250 MWe - BWR), AP600 or VVER-640.Current approaches for reactors with relatively small power, such as VVER 440 or AP600, use conservative assumptions for the safety demonstration. However, for higher power reactors (around 1000 MWe), the safety margin is reduced and it is necessary to evaluate the IVR strategy with best-estimate methods in order to reduce the uncertainties associated with the involved phenomena. Additional R&D as well as a revision of the methodology are needed to ensure and demonstrate adequate safety margins, including, in particular, best-estimate evaluations of thermal load applied on the vessel and mechanical resistance of the ablated vessel.The IVMR project (In-Vessel Melt Retention) was built with the goal of providing new knowledge (experimental, theoretical and technical) and a new methodology able to provide a best-estimate evaluation of IVR strategy for large power reactors. The main objective of Task 2.1 within WP2 was to define a common methodology to analyse IVR Severe Accident Management (SAM) strategy for the different types of EU NPPs. It started by reviewing the status of existing methodology and aimed at elaborating a more general, updated and less conservative one applicable to several types of reactors.This paper describes the proposed new methodology. It starts with the identification of the deficiencies of the standard methodology when it is applied to a high power reactor. It introduces the minimum vessel thickness as a parameter representing the cumulated imbalance between internal heat load and external cooling. Then it explains how to use that parameter in the evaluation of the safety margin. Although some examples are given as illustrations, it must be kept in mind that this paper proposes a generic methodology but there cannot be any generic conclusion: any reactor design must be evaluated independently.

Explore related subjects

Keep this discovery

BibTeXRIS

Florian Fichot, Laure Carénini, Stephan Brumm, Marco Sangiorgi. 2024-08-26. Methodology of safety evaluation of In-Vessel Retention. https://arxiv.org/abs/2408.14522

Cite the original work for its findings. Save a collection to share your selection of sources.

KEEP EXPLORING

Related papers

Phase-contrast micro-CT for intra-operative breast tumour margin assessment using a microfocus x-ray source and photon-counting detector

Objective: Intra-operative tumour margin assessment during breast-conserving surgery requires rapid, high-resolution imaging of excised tissue, allowing the surgical team to take appropriate action within a single operation. This study evaluates a custom propagation-based phase-contrast micro-computed tomography (micro-CT) system designed to meet these clinical constraints without specialised optical elements. Methods: The experimental setup pairs a microfocus x-ray source with a photon-counting detector in a cone-beam geometry. We explore how the spatial coherence of the source can provide propagation-based phase contrast -- with no additional specialised optical elements -- and balance this against maximising the x-ray flux of the cone-beam geometry. System performance was evaluated across two anode target materials and filtration configurations at various tube power settings. Imaging capabilities were validated using anthropomorphic breast tissue phantoms and a formalin-fixed paraffin-embedded (FFPE) breast tissue specimen, with reconstructions compared against gold-standard histology. Results: An unfiltered tungsten target operated at 40 kVp yielded optimal image quality. The optimised system achieved high-resolution CT reconstructions of a 5 cm diameter sample with an isotropic voxel size of 40.7 $\upmu\text{m}$ in a scan time of 12 minutes. Reconstructed volumes demonstrated strong visual correlation with corresponding histology slides. Conclusion: Combining a microfocus source with a photon-counting detector enables high-resolution, phase-contrast micro-CT within a clinically viable timeframe, demonstrating strong potential for intra-operative margin assessment.

physics.med-ph

Understanding Search and Decision Errors in Liver Metastasis Detection and the Effects of Lower Radiation Dose

The detection performance of liver metastases decreases with the reduction of radiation dose, but misses are heterogeneous. Previous eye tracking work has characterized missed metastases into two categories: search errors i.e., the eyes never land on the lesion, and decision errors i.e., the lesion is seen but not recognized as malignant. We integrated three prior reader studies to answer this question. In all studies, radiologists interpreted the same set of 40 contrast enhanced abdominal CT exams containing 91 liver metastases whose locations had been previously marked. In two studies, the workstation recorded their gaze and eye movements. Using eye dwell times, metastases were classified as search-error-dominant (majority of misses had <2 sec gaze time) or decision-error-dominant (>2 sec gaze time). In the third study, exams were interpreted both at 120 and 200 quality reference mAs (QRM) by ten radiologists. The third study did not include eye tracking. Out of 91 liver metastases, we excluded 16 that were never missed in the eye tracking studies and used 75 liver metastases for the present study.

physics.med-ph

Develop and Optimize 5DCT Imaging Simulation and Reconstruction Methods

Purpose: To develop and optimize a 5DCT (3D + cardiac phase + respiratory phase) imaging simulation and reconstruction pipeline, and to compare two sinogram-space interpolation methods for reconstructing images at arbitrary combinations of cardiac and respiratory phase. Methods: Helical CT projections were simulated from the 4D XCAT phantom across a range of cardiac and respiratory motion states, with Poisson and electronic noise added. Ground-truth-matched volumes were generated at 5 cardiac phases and 10 respiratory amplitudes (50 total phase combinations). Because acquired projections are sparsely and unevenly distributed across this joint phase space, each target slice was reconstructed by interpolating rebinned sinogram rows to the target cardiac phase and respiratory amplitude, using either 2D scattered barycentric interpolation or 2D scattered local linear interpolation with a circular kernel for cardiac phase. Reconstructed volumes were compared to phantom ground truth using mean absolute error (MAE), and to conventional respiratory-gated 4DCT (r4DCT) reconstructed from the same simulated data. Results: Both interpolation methods eliminated the severe axial misalignment artifacts present when helical projections were reconstructed without phase-space interpolation. Local linear interpolation achieved lower MAE than barycentric interpolation across most tested conditions, with the largest improvement at low pitch. The 5DCT pipeline also produced respiratory-only volumes with fewer residual cardiac-motion artifacts than conventional r4DCT reconstructed from the same projection data, including at standard clinical pitch (0.1). Conclusions: 5DCT reconstruction using sinogram-space interpolation is feasible and can jointly resolve cardiac and respiratory motion with better accuracy than conventional 4DCT reconstruction.

physics.med-ph