Analysis of critical points of the In-Vessel Retention safety evaluation

Abstract

In-Vessel Retention (IVR) strategy for nuclear reactors in case of a Severe Accident (SA) intends to stabilize and retain the corium in the vessel by using the vessel wall as a heat exchanger with an external water loop. This strategy relies on simple actions to be passively taken as soon as SA signal is raised: vessel depressurization and reactor pit flooding. Then, the strategy is successful if the vessel keeps it integrity, which means that the heat flux coming from the corium pool does not exceed the cooling capacity of the External Reactor Vessel Cooling (ERVC) at each location along the vessel wall (no vessel melt-through) and the ablated vessel wall is mechanically resistant. The main uncertainties in this IVR safety evaluation are associated to the thermal load applied from the corium pool to the vessel wall and the resulting minimum vessel thickness after ablation. Indeed, the heat fluxes distribution along the vessel wall is directly dependent on the corium stratification which occurs as aresult of thermochemical interactions in the pool: when liquid steel is mixed with UO2 and partially oxidized Zr coming from the degradation of the fuel and claddings, there is a phase separation between oxide and metal phases due to a gap of miscibility. The primordial impact of the corium behaviour in the lower plenum of the reactor vessel on the IVR safety evaluation was clearly highlighted in the Phenomena Identification Ranking Table (PIRT) on IVR performed in the frame of the European IVMR (In-Vessel Melt Retention) project (Fichot et al., 2019). As a result, the focus is made in this paper on the critical points which impact the value of the minimum vessel thickness orequivalently the maximum heat flux reached at the outer surface of the vessel wall. Efficiency of the ERVC and mechanical resistance of the vessel wall are consequently not discussed here.The main objective is to identify the generic critical situations leading to an excessive heat flux to the vessel wall and the investigation of possible means to avoid them. In this perspective, the calculations of IVR strategy done by the project partners for different reactor designs and accident scenarios were used as a database to identify and understand the occurrence of critical configurations with excessive heat flux to the vessel wall. The results of 25 sequences are used, which correspond to 9 different reactor designs: a generic PWR 900MWe, a PWR 1100MWe with heavy reflector, a generic PWR 1300MWe, a generic Konvoi 1300MWe, a generic German BWR69, aNordic BWR, a BWR-5 Mark II, a VVER1000 and a VVER440/v213. In addition, different SA integral codes (ASTEC, ATHLET-CD, MAAP -combined with MAAP_EDF and PROCOR codes for simulation of lower plenum behavior-, MELCOR and RELAP/SCDAPSIM codes) are used.

Explore related subjects

Keep this discovery

Explore connections, maps & timelines

BibTeXRIS

Laure Carénini, Florian Fichot. 2024-08-26. Analysis of critical points of the In-Vessel Retention safety evaluation. https://arxiv.org/abs/2408.15290

Cite the original work for its findings. Save a collection to share your selection of sources.

KEEP EXPLORING

Related papers

High-Speed Semi-FE Readout Module for ATLAS MDT at HL-LHC: Design and Production-Level Characterization

The High-Luminosity upgrade of the Large Hadron Collider (HL-LHC) introduces increased demands on the ATLAS Muon Spectrometer, particularly in terms of data throughput, timing distribution and system reliability. The Phase-II Chamber Service Module (CSM) is a key component of the upgraded Monitored Drift Tube (MDT) trigger and readout system, providing a high-speed interface between the front-end electronics and the backend systems. This paper describes the design and implementation of the Phase-II CSM, together with its validation. The results show that the CSM supports two independent optical uplinks, each operating at a line rate of 10.24 Gbps, together with clock distribution and slow control in the expected operating environment. Integration with small-diameter MDT (sMDT) chambers and tests with the prototype L0MDT trigger system are also presented. The CSM boards are now in production and will be used for installation and integration during the upcoming LHC Long Shutdown.

physics.ins-det

Spectral Discrimination of Deposited Gamma-Ray Energies in a Simulated CeBr$_3$ Scintillator

We show that wavelength measurements of individual detected optical photons may provide additional information about gamma-ray energy deposited in a CeBr$_3$ crystal when the detected-photon-count distributions overlap for nearby gamma-ray energies. Monoenergetic 662 and 629 keV gammas are used in a Geant4 simulation of a $25\times25\times20~\mathrm{mm^3}$ CeBr$_3$ crystal. Assuming a light yield of $6.0\times10^4$ photons/MeV, a wavelength-independent photon-detection efficiency of 30%, and a wavelength resolution of $\sigma_{\lambda}=40$ nm, we find that the fraction of photons reconstructed above 385 nm gives an event-level separation of $\sim$ 2 standard deviations between the 662 and 629 keV event populations selected within the same $\sim$ 1%-wide detected-photon-count interval. No timing or reconstructed interaction-position information is used. The result demonstrates, within the present simulation model, that event-dependent optical spectra can retain energy information beyond an undifferentiated photon count.

physics.ins-det

Operation of a negative ion gas time projection chamber without electronegative fill gases

The high fidelity reconstruction of particle tracks in micropatterned gaseous time projection chambers renders this technology ideal for future rare-event searches, including direction-sensitive dark matter experiments. Large drift distances are typically required for such experiments, so that the overall spatial resolution is limited by diffusion. Negative ion drift exhibits lower diffusion than electron drift and is thus an attractive option for realising a large-scale detector. The use of electronegative gases to create negative ions introduces technical challenges, most notably a reduction in gain when compared to conventional gas mixtures. In this study, we demonstrate a new method for negative ion generation via dissociative electron attachment using the conventional molecular fill gas CF$_4$. Our optical measurements of negative ion drift indicate electron attachment lengths of $<$1 mm and comparable gain to electron avalanches. The individual negative ion avalanches were also time-resolved, allowing the number of ions reaching the readout to be counted. We measure an improved energy resolution by single ion counting, relative to an integrated electron avalanche signal measured under identical gain conditions.

physics.ins-det