SearcharxivSearch

arXiv · 2409.13509

Redesign of the AD820 Single-Channel Circuit for the Development of the aRD820 Low-Noise Rail-to-Rail Operational Amplifier

Abstract

The task of this work was to design and later produce a low-power (single supply 5 - 30 V, dual supply +-2.5 V and +-15 V) rail-to-rail operational amplifier aRD820 with low voltage noise (<4 uV, p-p. 0.1 to 10 Hz), ultralow input bias current (< 15 pA), and low offset voltage (< 500 uV) characteristics. Similar characteristics are presented by Analog Devices chip AD820. Thus, the task of the design team was to adapt the prototype circuity of AD820 to our technological capabilities, modify the circuit, if necessary, to eliminate any deficiency of the prototype. The input stage module got source followers at the input of the operational amplifier. Second stage module was modified to be more symmetric. The output stage module obtained additional resistors and capacitors to achieve a frequency compensation. One FET transistor in the current reference module was substituted by other elements. Simplified electric schemes of these modules of AR820 and aRD820 are presented. The performance of modified electric schemes of modules was tested in Simulink software. Simulations of the full electric scheme for aRD820 were made and showed that it demonstrates similar characteristics as AD820 data tables. Later production of the aRD820 chip and measurements demonstrated that the planned characteristics of the operational amplifier were met.

Explore related subjects

Keep this discovery

BibTeXRIS

Dmitry Kostrichkin, Sergey Rudenko, Mihails Lapkis, Aigars Atvars. 2024-09-20. Redesign of the AD820 Single-Channel Circuit for the Development of the aRD820 Low-Noise Rail-to-Rail Operational Amplifier. https://arxiv.org/abs/2409.13509

Cite the original work for its findings. Save a collection to share your selection of sources.

KEEP EXPLORING

Related papers

High-Speed Semi-FE Readout Module for ATLAS MDT at HL-LHC: Design and Production-Level Characterization

The High-Luminosity upgrade of the Large Hadron Collider (HL-LHC) introduces increased demands on the ATLAS Muon Spectrometer, particularly in terms of data throughput, timing distribution and system reliability. The Phase-II Chamber Service Module (CSM) is a key component of the upgraded Monitored Drift Tube (MDT) trigger and readout system, providing a high-speed interface between the front-end electronics and the backend systems. This paper describes the design and implementation of the Phase-II CSM, together with its validation. The results show that the CSM supports two independent optical uplinks, each operating at a line rate of 10.24 Gbps, together with clock distribution and slow control in the expected operating environment. Integration with small-diameter MDT (sMDT) chambers and tests with the prototype L0MDT trigger system are also presented. The CSM boards are now in production and will be used for installation and integration during the upcoming LHC Long Shutdown.

physics.ins-det

Spectral Discrimination of Deposited Gamma-Ray Energies in a Simulated CeBr$_3$ Scintillator

We show that wavelength measurements of individual detected optical photons may provide additional information about gamma-ray energy deposited in a CeBr$_3$ crystal when the detected-photon-count distributions overlap for nearby gamma-ray energies. Monoenergetic 662 and 629 keV gammas are used in a Geant4 simulation of a $25\times25\times20~\mathrm{mm^3}$ CeBr$_3$ crystal. Assuming a light yield of $6.0\times10^4$ photons/MeV, a wavelength-independent photon-detection efficiency of 30%, and a wavelength resolution of $\sigma_{\lambda}=40$ nm, we find that the fraction of photons reconstructed above 385 nm gives an event-level separation of $\sim$ 2 standard deviations between the 662 and 629 keV event populations selected within the same $\sim$ 1%-wide detected-photon-count interval. No timing or reconstructed interaction-position information is used. The result demonstrates, within the present simulation model, that event-dependent optical spectra can retain energy information beyond an undifferentiated photon count.

physics.ins-det

Operation of a negative ion gas time projection chamber without electronegative fill gases

The high fidelity reconstruction of particle tracks in micropatterned gaseous time projection chambers renders this technology ideal for future rare-event searches, including direction-sensitive dark matter experiments. Large drift distances are typically required for such experiments, so that the overall spatial resolution is limited by diffusion. Negative ion drift exhibits lower diffusion than electron drift and is thus an attractive option for realising a large-scale detector. The use of electronegative gases to create negative ions introduces technical challenges, most notably a reduction in gain when compared to conventional gas mixtures. In this study, we demonstrate a new method for negative ion generation via dissociative electron attachment using the conventional molecular fill gas CF$_4$. Our optical measurements of negative ion drift indicate electron attachment lengths of $<$1 mm and comparable gain to electron avalanches. The individual negative ion avalanches were also time-resolved, allowing the number of ions reaching the readout to be counted. We measure an improved energy resolution by single ion counting, relative to an integrated electron avalanche signal measured under identical gain conditions.

physics.ins-det