SearcharxivSearch

arXiv · 2410.02632

Quantification of the Plan Aperture Modulation of Radiotherapy Treatment Plans

Abstract

This study introduces a novel metric, Plan Aperture Modulation (PAM), developed to quantify the modulation of radiotherapy treatment plans. PAM aims to provide a clear geometric interpretation, addressing the limitations of previous complexity metrics and facilitating its integration into treatment planning systems (TPSs) and clinical workflows. The PAM metric was defined as the average fraction of the target area outside the beam aperture, weighted over all control points in a treatment plan. The metric was evaluated in VMAT plans for two sites: prostate with lymph nodes and lung SBRT. Plans with varying complexities were generated using the Eclipse TPS, and PAM was compared to established metrics, including Plan Modulation (PM), Modulation Complexity Score (MCS), and monitor units per Gray (MU/Gy). The relationship between PAM and the Modulation Factor (MF), which quantifies the increase in MUs due to plan modulation, was also investigated. PAM provided a more intuitive assessment of plan modulation compared to the other metrics, and was validated across different delivery systems, such as C-arm linacs and Halcyon systems. The metric outperformed the previous metrics, indicated a zero modulation for Dynamic Conformal Arc plans, and was independent of confounding variables, such as treatment technique, beam energy, delivery system, and patient anatomy. Derived equations enabled the calculation of MF based on PAM, allowing for a robust quantification of plan modulation. PAM is a robust and intuitive metric for quantifying modulation in radiotherapy plans. It overcomes the limitations of previous metrics and can be readily implemented in TPSs to control plan modulation during optimization and for reporting. PAM is a promising tool for improving treatment planning workflows and for comparing and benchmarking radiotherapy plans in multi-institutional studies, clinical trials, and audits.

Explore related subjects

Keep this discovery

BibTeXRIS

Victor Hernandez, Iñigo Lara-Aristimuño, Ruben Abella, Jordi Saez. 2024-10-03. Quantification of the Plan Aperture Modulation of Radiotherapy Treatment Plans. https://doi.org/10.1002/mp.70144

Cite the original work for its findings. Save a collection to share your selection of sources.

KEEP EXPLORING

Related papers

Phase-contrast micro-CT for intra-operative breast tumour margin assessment using a microfocus x-ray source and photon-counting detector

Objective: Intra-operative tumour margin assessment during breast-conserving surgery requires rapid, high-resolution imaging of excised tissue, allowing the surgical team to take appropriate action within a single operation. This study evaluates a custom propagation-based phase-contrast micro-computed tomography (micro-CT) system designed to meet these clinical constraints without specialised optical elements. Methods: The experimental setup pairs a microfocus x-ray source with a photon-counting detector in a cone-beam geometry. We explore how the spatial coherence of the source can provide propagation-based phase contrast -- with no additional specialised optical elements -- and balance this against maximising the x-ray flux of the cone-beam geometry. System performance was evaluated across two anode target materials and filtration configurations at various tube power settings. Imaging capabilities were validated using anthropomorphic breast tissue phantoms and a formalin-fixed paraffin-embedded (FFPE) breast tissue specimen, with reconstructions compared against gold-standard histology. Results: An unfiltered tungsten target operated at 40 kVp yielded optimal image quality. The optimised system achieved high-resolution CT reconstructions of a 5 cm diameter sample with an isotropic voxel size of 40.7 $\upmu\text{m}$ in a scan time of 12 minutes. Reconstructed volumes demonstrated strong visual correlation with corresponding histology slides. Conclusion: Combining a microfocus source with a photon-counting detector enables high-resolution, phase-contrast micro-CT within a clinically viable timeframe, demonstrating strong potential for intra-operative margin assessment.

physics.med-ph

Understanding Search and Decision Errors in Liver Metastasis Detection and the Effects of Lower Radiation Dose

The detection performance of liver metastases decreases with the reduction of radiation dose, but misses are heterogeneous. Previous eye tracking work has characterized missed metastases into two categories: search errors i.e., the eyes never land on the lesion, and decision errors i.e., the lesion is seen but not recognized as malignant. We integrated three prior reader studies to answer this question. In all studies, radiologists interpreted the same set of 40 contrast enhanced abdominal CT exams containing 91 liver metastases whose locations had been previously marked. In two studies, the workstation recorded their gaze and eye movements. Using eye dwell times, metastases were classified as search-error-dominant (majority of misses had <2 sec gaze time) or decision-error-dominant (>2 sec gaze time). In the third study, exams were interpreted both at 120 and 200 quality reference mAs (QRM) by ten radiologists. The third study did not include eye tracking. Out of 91 liver metastases, we excluded 16 that were never missed in the eye tracking studies and used 75 liver metastases for the present study.

physics.med-ph

Develop and Optimize 5DCT Imaging Simulation and Reconstruction Methods

Purpose: To develop and optimize a 5DCT (3D + cardiac phase + respiratory phase) imaging simulation and reconstruction pipeline, and to compare two sinogram-space interpolation methods for reconstructing images at arbitrary combinations of cardiac and respiratory phase. Methods: Helical CT projections were simulated from the 4D XCAT phantom across a range of cardiac and respiratory motion states, with Poisson and electronic noise added. Ground-truth-matched volumes were generated at 5 cardiac phases and 10 respiratory amplitudes (50 total phase combinations). Because acquired projections are sparsely and unevenly distributed across this joint phase space, each target slice was reconstructed by interpolating rebinned sinogram rows to the target cardiac phase and respiratory amplitude, using either 2D scattered barycentric interpolation or 2D scattered local linear interpolation with a circular kernel for cardiac phase. Reconstructed volumes were compared to phantom ground truth using mean absolute error (MAE), and to conventional respiratory-gated 4DCT (r4DCT) reconstructed from the same simulated data. Results: Both interpolation methods eliminated the severe axial misalignment artifacts present when helical projections were reconstructed without phase-space interpolation. Local linear interpolation achieved lower MAE than barycentric interpolation across most tested conditions, with the largest improvement at low pitch. The 5DCT pipeline also produced respiratory-only volumes with fewer residual cardiac-motion artifacts than conventional r4DCT reconstructed from the same projection data, including at standard clinical pitch (0.1). Conclusions: 5DCT reconstruction using sinogram-space interpolation is feasible and can jointly resolve cardiac and respiratory motion with better accuracy than conventional 4DCT reconstruction.

physics.med-ph