SearcharxivSearch

arXiv · 2410.09313

FPGA-based digitizer for BGO-based time-of-flight PET

Abstract

We present a novel FPGA-based bismuth germanate (BGO) time-of-flight (TOF) digitizer, implemented on an FPGA (VC707 evaluation kit, Xilinx). This digitizer was designed to address the recently highlighted characteristics of BGO, which generates scintillation and prompt Cerenkov photons when 511-keV photon interacts with BGO. The developed digitizer independently processes these two types of photons for precise energy and timing measurements. The digitizer incorporates a noise-resistant binary counter that measures energy signals using a time-over-threshold (TOT) method. For timing measurement, we employ an embedded dual-side monitoring time-to-digital converter (TDC), which efficiently captures timing information while maintaining low resource usage. We validated the efficacy of our FPGA-based TOF digitizer through extensive experiments, including both an electrical setup and a coincidence test using BGO pixels. Our evaluations of TOT energy and timing performance utilized two $3 \times 3 \times 20 \ \text{mm}^3$ BGO pixels coupled to CHK-HD MT silicon photomultipliers (SiPMs). The digitizer achieved a coincidence timing resolution (CTR) of 407 ps full width at half maximum (FWHM) for coincidence events falling within the full width at tenth maximum (FWTM) of the measured TOT energy spectrum. Notably, when measured with an oscilloscope, the same detector pair exhibited a CTR of 403 ps FWHM, confirming that the performance of the developed digitizer is comparable to that of oscilloscopes. With the low resource usage of our design, it offers significant potential for scalability, making it particularly promising for multi-channel BGO-based PET systems.

Explore related subjects

Keep this discovery

BibTeXRIS

Daehee Lee, Sun Il Kwon. 2024-10-12. FPGA-based digitizer for BGO-based time-of-flight PET. https://arxiv.org/abs/2410.09313

Cite the original work for its findings. Save a collection to share your selection of sources.

KEEP EXPLORING

Related papers

High-Speed Semi-FE Readout Module for ATLAS MDT at HL-LHC: Design and Production-Level Characterization

The High-Luminosity upgrade of the Large Hadron Collider (HL-LHC) introduces increased demands on the ATLAS Muon Spectrometer, particularly in terms of data throughput, timing distribution and system reliability. The Phase-II Chamber Service Module (CSM) is a key component of the upgraded Monitored Drift Tube (MDT) trigger and readout system, providing a high-speed interface between the front-end electronics and the backend systems. This paper describes the design and implementation of the Phase-II CSM, together with its validation. The results show that the CSM supports two independent optical uplinks, each operating at a line rate of 10.24 Gbps, together with clock distribution and slow control in the expected operating environment. Integration with small-diameter MDT (sMDT) chambers and tests with the prototype L0MDT trigger system are also presented. The CSM boards are now in production and will be used for installation and integration during the upcoming LHC Long Shutdown.

physics.ins-det

Spectral Discrimination of Deposited Gamma-Ray Energies in a Simulated CeBr$_3$ Scintillator

We show that wavelength measurements of individual detected optical photons may provide additional information about gamma-ray energy deposited in a CeBr$_3$ crystal when the detected-photon-count distributions overlap for nearby gamma-ray energies. Monoenergetic 662 and 629 keV gammas are used in a Geant4 simulation of a $25\times25\times20~\mathrm{mm^3}$ CeBr$_3$ crystal. Assuming a light yield of $6.0\times10^4$ photons/MeV, a wavelength-independent photon-detection efficiency of 30%, and a wavelength resolution of $\sigma_{\lambda}=40$ nm, we find that the fraction of photons reconstructed above 385 nm gives an event-level separation of $\sim$ 2 standard deviations between the 662 and 629 keV event populations selected within the same $\sim$ 1%-wide detected-photon-count interval. No timing or reconstructed interaction-position information is used. The result demonstrates, within the present simulation model, that event-dependent optical spectra can retain energy information beyond an undifferentiated photon count.

physics.ins-det

Operation of a negative ion gas time projection chamber without electronegative fill gases

The high fidelity reconstruction of particle tracks in micropatterned gaseous time projection chambers renders this technology ideal for future rare-event searches, including direction-sensitive dark matter experiments. Large drift distances are typically required for such experiments, so that the overall spatial resolution is limited by diffusion. Negative ion drift exhibits lower diffusion than electron drift and is thus an attractive option for realising a large-scale detector. The use of electronegative gases to create negative ions introduces technical challenges, most notably a reduction in gain when compared to conventional gas mixtures. In this study, we demonstrate a new method for negative ion generation via dissociative electron attachment using the conventional molecular fill gas CF$_4$. Our optical measurements of negative ion drift indicate electron attachment lengths of $<$1 mm and comparable gain to electron avalanches. The individual negative ion avalanches were also time-resolved, allowing the number of ions reaching the readout to be counted. We measure an improved energy resolution by single ion counting, relative to an integrated electron avalanche signal measured under identical gain conditions.

physics.ins-det