SearcharxivSearch

arXiv · 2410.09317

Cross-Detection and Dual-Side Monitoring Schemes for FPGA-Based High-Accuracy and High-Precision Time-to-Digital Converters

Abstract

This study presents a novel field-programmable gate array (FPGA)-based Time-to-Digital Converter (TDC) design suitable for high timing resolution applications, utilizing two new techniques. First, a cross-detection (CD) method is introduced that minimizes the occurrence of bubbles, which cause inaccuracy in the timing measurement of a TDC in thermometer codes, by altering the conventional sampling pattern, thereby yielding an average bin size half of its typical size. The second technique employs dual-side monitoring (DSM) of thermometer codes, including end-of-propagation (EOP) and start-of-propagation (SOP). Distinct from conventional TDCs, which focus solely on SOP thermometer codes, this technique utilizes EOP to calibrate SOP, simultaneously enhancing time resolution and the TDC's stability against changes in temperature and location. The proposed DSM scheme necessitates only an additional CARRY4 for capturing the EOP thermometer code, rendering it a resource-efficient solution. The CD-DSM TDC has been successfully implemented on a Virtex-7 Xilinx FPGA (a 28-nm process), with an average bin size of 6.1 ps and a root mean square of 3.8 ps. Compared to conventional TDCs, the CD-DSM TDC offers superior linearity. The successful measurement of ultra-high coincidence timing resolution (CTR) from two Cerenkov radiator integrated microchannel plate photomultiplier tubes (CRI-MCP-PMTs) was conducted with the CD-DSM TDCs for sub-100 ps timing measurements. A comparison with current-edge TDCs further highlights the superior performance of the CD-DSM TDCs.

Explore related subjects

Keep this discovery

BibTeXRIS

Daehee Lee, Minseok Yi, Sun Il Kwon. 2024-10-12. Cross-Detection and Dual-Side Monitoring Schemes for FPGA-Based High-Accuracy and High-Precision Time-to-Digital Converters. https://arxiv.org/abs/2410.09317

Cite the original work for its findings. Save a collection to share your selection of sources.

KEEP EXPLORING

Related papers

High-Speed Semi-FE Readout Module for ATLAS MDT at HL-LHC: Design and Production-Level Characterization

The High-Luminosity upgrade of the Large Hadron Collider (HL-LHC) introduces increased demands on the ATLAS Muon Spectrometer, particularly in terms of data throughput, timing distribution and system reliability. The Phase-II Chamber Service Module (CSM) is a key component of the upgraded Monitored Drift Tube (MDT) trigger and readout system, providing a high-speed interface between the front-end electronics and the backend systems. This paper describes the design and implementation of the Phase-II CSM, together with its validation. The results show that the CSM supports two independent optical uplinks, each operating at a line rate of 10.24 Gbps, together with clock distribution and slow control in the expected operating environment. Integration with small-diameter MDT (sMDT) chambers and tests with the prototype L0MDT trigger system are also presented. The CSM boards are now in production and will be used for installation and integration during the upcoming LHC Long Shutdown.

physics.ins-det

Spectral Discrimination of Deposited Gamma-Ray Energies in a Simulated CeBr$_3$ Scintillator

We show that wavelength measurements of individual detected optical photons may provide additional information about gamma-ray energy deposited in a CeBr$_3$ crystal when the detected-photon-count distributions overlap for nearby gamma-ray energies. Monoenergetic 662 and 629 keV gammas are used in a Geant4 simulation of a $25\times25\times20~\mathrm{mm^3}$ CeBr$_3$ crystal. Assuming a light yield of $6.0\times10^4$ photons/MeV, a wavelength-independent photon-detection efficiency of 30%, and a wavelength resolution of $\sigma_{\lambda}=40$ nm, we find that the fraction of photons reconstructed above 385 nm gives an event-level separation of $\sim$ 2 standard deviations between the 662 and 629 keV event populations selected within the same $\sim$ 1%-wide detected-photon-count interval. No timing or reconstructed interaction-position information is used. The result demonstrates, within the present simulation model, that event-dependent optical spectra can retain energy information beyond an undifferentiated photon count.

physics.ins-det

Operation of a negative ion gas time projection chamber without electronegative fill gases

The high fidelity reconstruction of particle tracks in micropatterned gaseous time projection chambers renders this technology ideal for future rare-event searches, including direction-sensitive dark matter experiments. Large drift distances are typically required for such experiments, so that the overall spatial resolution is limited by diffusion. Negative ion drift exhibits lower diffusion than electron drift and is thus an attractive option for realising a large-scale detector. The use of electronegative gases to create negative ions introduces technical challenges, most notably a reduction in gain when compared to conventional gas mixtures. In this study, we demonstrate a new method for negative ion generation via dissociative electron attachment using the conventional molecular fill gas CF$_4$. Our optical measurements of negative ion drift indicate electron attachment lengths of $<$1 mm and comparable gain to electron avalanches. The individual negative ion avalanches were also time-resolved, allowing the number of ions reaching the readout to be counted. We measure an improved energy resolution by single ion counting, relative to an integrated electron avalanche signal measured under identical gain conditions.

physics.ins-det