Abstract

Scintillator-based X-ray imaging detectors are pivotal in numerous scientific and practical domains, including medical imaging, and security monitoring. Recent advancements have spurred interest in 4D X-ray imaging using synchrotron radiation, necessitating higher temporal resolutions. Consequently, this places stringent demands on X-ray detector technology, especially when X-ray energy exceeds 20 keV. The selection of a suitable scintillator material is crucial for achieving optimal timing resolution, yet it poses a significant challenge in dynamic X-ray imaging. This study delves into the optimization of scintillator properties and their impact on spatial resolution and light output, elucidating the performance of Ce-doped Gd3Ga3Al2O12 (GAGG:Ce) scintillators for X-ray imaging applications. We developed a micro X-ray imaging detector using a 100 $\mu$m-thick GAGG:Ce scintillator plate and conducted X-ray imaging tests at the Aichi SR facility. The results demonstrated that the resolution, quantified as the chart slit width at a contrast transfer function (CTF) value of 10%, reached 2 - 3 $\mu$m with a 4x lens, 0.52 $\mu$m $\pm$ 0.03 $\mu$m with a 20x lens, and 0.42 $\mu$m $\pm$ 0.01 $\mu$m with a 40x lens. Although the results of this study did not achieve a spatial resolution nearing the effective pixel size of the 40x lens, the text also elucidates the underlying reasons for this limitation. Furthermore, we compared the X-ray sensitivity of our GAGG:Ce scintillator plate with that of a commercial LuAG:Ce scintillator, revealing an approximately 1.5-fold increase in light output. As a demonstration, transmission images of dried small fish were captured using the GAGG:Ce scintillator plate and the developed X-ray imaging system. These findings highlight the potential of the X-ray imaging detector devised in this study for future generations of X-ray imaging applications.

Explore related subjects

Keep this discovery

BibTeXRIS

Masao Yoshino, Seiichi Yamamoto, Kohei Nakanishi, Katsunori Yogo, Kei Kamada, Nanase Koshikawa, Jun Kataoka, Akira Yoshikawa. 2024-10-12. Development and performance evaluation of a thin GAGG:Ce scintillator plate for high resolution synchrotron radiation X-ray imaging. https://doi.org/10.1088/1748-0221%2F19%2F10%2Fp10030

Cite the original work for its findings. Save a collection to share your selection of sources.

KEEP EXPLORING

Related papers

High-Speed Semi-FE Readout Module for ATLAS MDT at HL-LHC: Design and Production-Level Characterization

The High-Luminosity upgrade of the Large Hadron Collider (HL-LHC) introduces increased demands on the ATLAS Muon Spectrometer, particularly in terms of data throughput, timing distribution and system reliability. The Phase-II Chamber Service Module (CSM) is a key component of the upgraded Monitored Drift Tube (MDT) trigger and readout system, providing a high-speed interface between the front-end electronics and the backend systems. This paper describes the design and implementation of the Phase-II CSM, together with its validation. The results show that the CSM supports two independent optical uplinks, each operating at a line rate of 10.24 Gbps, together with clock distribution and slow control in the expected operating environment. Integration with small-diameter MDT (sMDT) chambers and tests with the prototype L0MDT trigger system are also presented. The CSM boards are now in production and will be used for installation and integration during the upcoming LHC Long Shutdown.

physics.ins-det

Spectral Discrimination of Deposited Gamma-Ray Energies in a Simulated CeBr$_3$ Scintillator

We show that wavelength measurements of individual detected optical photons may provide additional information about gamma-ray energy deposited in a CeBr$_3$ crystal when the detected-photon-count distributions overlap for nearby gamma-ray energies. Monoenergetic 662 and 629 keV gammas are used in a Geant4 simulation of a $25\times25\times20~\mathrm{mm^3}$ CeBr$_3$ crystal. Assuming a light yield of $6.0\times10^4$ photons/MeV, a wavelength-independent photon-detection efficiency of 30%, and a wavelength resolution of $\sigma_{\lambda}=40$ nm, we find that the fraction of photons reconstructed above 385 nm gives an event-level separation of $\sim$ 2 standard deviations between the 662 and 629 keV event populations selected within the same $\sim$ 1%-wide detected-photon-count interval. No timing or reconstructed interaction-position information is used. The result demonstrates, within the present simulation model, that event-dependent optical spectra can retain energy information beyond an undifferentiated photon count.

physics.ins-det

Operation of a negative ion gas time projection chamber without electronegative fill gases

The high fidelity reconstruction of particle tracks in micropatterned gaseous time projection chambers renders this technology ideal for future rare-event searches, including direction-sensitive dark matter experiments. Large drift distances are typically required for such experiments, so that the overall spatial resolution is limited by diffusion. Negative ion drift exhibits lower diffusion than electron drift and is thus an attractive option for realising a large-scale detector. The use of electronegative gases to create negative ions introduces technical challenges, most notably a reduction in gain when compared to conventional gas mixtures. In this study, we demonstrate a new method for negative ion generation via dissociative electron attachment using the conventional molecular fill gas CF$_4$. Our optical measurements of negative ion drift indicate electron attachment lengths of $<$1 mm and comparable gain to electron avalanches. The individual negative ion avalanches were also time-resolved, allowing the number of ions reaching the readout to be counted. We measure an improved energy resolution by single ion counting, relative to an integrated electron avalanche signal measured under identical gain conditions.

physics.ins-det