Abstract

Microplastics are pervasive pollutants that pose threats to the environment and human health. Detecting them reliably represents a crucial step toward finding solutions. While traditional techniques like vibrational and mass spectroscopies are time-consuming and have limitations in analysing polymers with pigment additives, surface plasmon resonance (SPR) shows promise due to its high sensitivity and rapid detection capabilities.However, existing SPR methods rely on one output variable and fail to determine various microplastic parameters simultaneously. To address this uncertainty between size and polymer type, we propose a prism design that enables SPR resonance in a refractive index range of 1.402-1.56 RIU (Refractive Index Units) for polymer detection. Experimental verification of the prism's dynamic range using refractive index oils presented an agreement of 98.47% with theoretical analysis. Furthermore, we acquired SPR curves from ten different polymer types, including Nitrile, Viton and Tyre rubber. These results demonstrate SPR's potential to identify polymers and its ability to detect even pigmented materials, often challenging for other techniques. The imaging capabilities of the novel prism are presented, indicating its potential for future imaging of microplastics. Our approach holds promise for advancing microplastics analysis by enabling comprehensive assessment of particle parameters, such as polymer type, size, quantity and shape, and expanding the range of detectable polymer types.

Explore related subjects

Keep this discovery

BibTeXRIS

Natalia A. Gutierrez Andrade, Yunfeng Nie, Wendy Meulebroeck, Heidi Ottevaere. 2024-10-16. Surface plasmon resonance sensor based on a novel prism for the detection of a broad range of polymers. https://doi.org/10.1016/j.sna.2025.116656

Cite the original work for its findings. Save a collection to share your selection of sources.

KEEP EXPLORING

Related papers

High-Speed Semi-FE Readout Module for ATLAS MDT at HL-LHC: Design and Production-Level Characterization

The High-Luminosity upgrade of the Large Hadron Collider (HL-LHC) introduces increased demands on the ATLAS Muon Spectrometer, particularly in terms of data throughput, timing distribution and system reliability. The Phase-II Chamber Service Module (CSM) is a key component of the upgraded Monitored Drift Tube (MDT) trigger and readout system, providing a high-speed interface between the front-end electronics and the backend systems. This paper describes the design and implementation of the Phase-II CSM, together with its validation. The results show that the CSM supports two independent optical uplinks, each operating at a line rate of 10.24 Gbps, together with clock distribution and slow control in the expected operating environment. Integration with small-diameter MDT (sMDT) chambers and tests with the prototype L0MDT trigger system are also presented. The CSM boards are now in production and will be used for installation and integration during the upcoming LHC Long Shutdown.

physics.ins-det

Spectral Discrimination of Deposited Gamma-Ray Energies in a Simulated CeBr$_3$ Scintillator

We show that wavelength measurements of individual detected optical photons may provide additional information about gamma-ray energy deposited in a CeBr$_3$ crystal when the detected-photon-count distributions overlap for nearby gamma-ray energies. Monoenergetic 662 and 629 keV gammas are used in a Geant4 simulation of a $25\times25\times20~\mathrm{mm^3}$ CeBr$_3$ crystal. Assuming a light yield of $6.0\times10^4$ photons/MeV, a wavelength-independent photon-detection efficiency of 30%, and a wavelength resolution of $\sigma_{\lambda}=40$ nm, we find that the fraction of photons reconstructed above 385 nm gives an event-level separation of $\sim$ 2 standard deviations between the 662 and 629 keV event populations selected within the same $\sim$ 1%-wide detected-photon-count interval. No timing or reconstructed interaction-position information is used. The result demonstrates, within the present simulation model, that event-dependent optical spectra can retain energy information beyond an undifferentiated photon count.

physics.ins-det

Operation of a negative ion gas time projection chamber without electronegative fill gases

The high fidelity reconstruction of particle tracks in micropatterned gaseous time projection chambers renders this technology ideal for future rare-event searches, including direction-sensitive dark matter experiments. Large drift distances are typically required for such experiments, so that the overall spatial resolution is limited by diffusion. Negative ion drift exhibits lower diffusion than electron drift and is thus an attractive option for realising a large-scale detector. The use of electronegative gases to create negative ions introduces technical challenges, most notably a reduction in gain when compared to conventional gas mixtures. In this study, we demonstrate a new method for negative ion generation via dissociative electron attachment using the conventional molecular fill gas CF$_4$. Our optical measurements of negative ion drift indicate electron attachment lengths of $<$1 mm and comparable gain to electron avalanches. The individual negative ion avalanches were also time-resolved, allowing the number of ions reaching the readout to be counted. We measure an improved energy resolution by single ion counting, relative to an integrated electron avalanche signal measured under identical gain conditions.

physics.ins-det