Investigation of Vibrational Frequency of Canine Vocal Folds Using a Two-Way Fluid-Solid Interaction Analysis

Abstract

Introduction Speech is an integral component of human communication, requiring the coordinated efforts of various organs to produce sound (Titze & Alipour, 2006). The glottis region, a key player in voice production, assumes a crucial role in this intricate process. As air, emanating from the lungs in a confined space, interacts with the vocal folds (VFs) within the human body, it gives rise to the creation of voice (Alipour & Vigmostad, 2012). Understanding the mechanical intricacies of this process is very important. Studying VFs in vivo situations is hard work. However, the orientation, shape and size of VFs fibers have been extracted with synchrotron X-ray microtomography. (Bailly et al., 2018) The investigation of mechanical properties of both human and animal VFs has been carried out through various methodologies in the literature. The mechanical properties of VFs have been studied using the uniaxial extension test (Alipour & Vigmostad, 2012) assuming a linear behavior, while the nonlinearity and anisotropy of VFs has been determined using a multiscale method as in Miri et al. (2013). Pipette aspiration has also been used to extract in vivo elastic properties of VFs (Scheible et al., 2023). Mechanical behavior of VFs layers in tension, compression and shear has been studied. (Cochereau et al., 2020). Fluid-structure interaction (FSI) simulations provide a valuable tool to gain a deeper understanding of voice production (Ghorbani et al. 2022). These simulations allow us to model the dynamic interplay between the VFs and air. Our research focuses on investigating the mechanical properties of canine vocal folds and utilizing these findings in an FSI simulation. Through this simulation, we aim to unravel how these mechanical properties affect voice production.Methods To investigate the mechanical properties of canine VFs, an in vitro study was conducted involving 6 mixedbreed dogs. The samples were harvested from canine cadavers euthanized for reasons unrelated to this study. In the following, the VFs were harvested and tested upon 3-4 hours post-animal sacrifice. Experimental trials were carried out using the STM-1 device (SANTAM Co.), equipped with a 100 kg load cell. Seven uniaxial tensile tests were done on each sample, with displacement rates of 1, 5, 10, 20, 40, 60, and 120 mm/min. The very slow rate of 1 mm/min was chosen to assess only elastic properties eliminating viscosity effects. Various hyperelastic models were used to fit the experimental data. Subsequently, for each model, both the mean and standard deviation (SD) were determined for the hyperelastic model parameters and their residuals. For FSI analysis we used a simplified laryngeal model as a hollow cylinder with a diameter of 50 mm and a thickness of 3 mm. The overall length of the larynx was set at 100 mm. The VFs were modeled as a circular disc with a small elliptical fissure in the midst of the cylinder section. Boundary conditions were established based on pressure differentials, with the inlet gauge pressure set at 1200 Pa and the relative pressure at the outlet set to 0. To account for the turbulent nature of airflow within the larynx, we employed the K-epsilon method to solve the motion differential equations in a two-way fluid-structure interaction simulation using ANSYS FLUENT 2021. This approach enabled us to investigate how the acquired mechanical properties of canine vocal folds affect the FSI simulations during phonation, resulting in a more comprehensive understanding of their impact. To determine the vibrational frequency of VFs, we calculated the time it took to reach maximum displacement and then quadrupled this value to obtain the period of vibration.

Explore related subjects

Keep this discovery

BibTeXRIS

Abolfazl Mohammadi Gorjaei, Mohammad Ali Nazari, Asghar Afshari, Saeed Farzad-Mohajeri, Pascal Perrier. 2024-11-19. Investigation of Vibrational Frequency of Canine Vocal Folds Using a Two-Way Fluid-Solid Interaction Analysis. https://arxiv.org/abs/2411.12291

Cite the original work for its findings. Save a collection to share your selection of sources.

KEEP EXPLORING

Related papers

Phase-contrast micro-CT for intra-operative breast tumour margin assessment using a microfocus x-ray source and photon-counting detector

Objective: Intra-operative tumour margin assessment during breast-conserving surgery requires rapid, high-resolution imaging of excised tissue, allowing the surgical team to take appropriate action within a single operation. This study evaluates a custom propagation-based phase-contrast micro-computed tomography (micro-CT) system designed to meet these clinical constraints without specialised optical elements. Methods: The experimental setup pairs a microfocus x-ray source with a photon-counting detector in a cone-beam geometry. We explore how the spatial coherence of the source can provide propagation-based phase contrast -- with no additional specialised optical elements -- and balance this against maximising the x-ray flux of the cone-beam geometry. System performance was evaluated across two anode target materials and filtration configurations at various tube power settings. Imaging capabilities were validated using anthropomorphic breast tissue phantoms and a formalin-fixed paraffin-embedded (FFPE) breast tissue specimen, with reconstructions compared against gold-standard histology. Results: An unfiltered tungsten target operated at 40 kVp yielded optimal image quality. The optimised system achieved high-resolution CT reconstructions of a 5 cm diameter sample with an isotropic voxel size of 40.7 $\upmu\text{m}$ in a scan time of 12 minutes. Reconstructed volumes demonstrated strong visual correlation with corresponding histology slides. Conclusion: Combining a microfocus source with a photon-counting detector enables high-resolution, phase-contrast micro-CT within a clinically viable timeframe, demonstrating strong potential for intra-operative margin assessment.

physics.med-ph

Understanding Search and Decision Errors in Liver Metastasis Detection and the Effects of Lower Radiation Dose

The detection performance of liver metastases decreases with the reduction of radiation dose, but misses are heterogeneous. Previous eye tracking work has characterized missed metastases into two categories: search errors i.e., the eyes never land on the lesion, and decision errors i.e., the lesion is seen but not recognized as malignant. We integrated three prior reader studies to answer this question. In all studies, radiologists interpreted the same set of 40 contrast enhanced abdominal CT exams containing 91 liver metastases whose locations had been previously marked. In two studies, the workstation recorded their gaze and eye movements. Using eye dwell times, metastases were classified as search-error-dominant (majority of misses had <2 sec gaze time) or decision-error-dominant (>2 sec gaze time). In the third study, exams were interpreted both at 120 and 200 quality reference mAs (QRM) by ten radiologists. The third study did not include eye tracking. Out of 91 liver metastases, we excluded 16 that were never missed in the eye tracking studies and used 75 liver metastases for the present study.

physics.med-ph

Develop and Optimize 5DCT Imaging Simulation and Reconstruction Methods

Purpose: To develop and optimize a 5DCT (3D + cardiac phase + respiratory phase) imaging simulation and reconstruction pipeline, and to compare two sinogram-space interpolation methods for reconstructing images at arbitrary combinations of cardiac and respiratory phase. Methods: Helical CT projections were simulated from the 4D XCAT phantom across a range of cardiac and respiratory motion states, with Poisson and electronic noise added. Ground-truth-matched volumes were generated at 5 cardiac phases and 10 respiratory amplitudes (50 total phase combinations). Because acquired projections are sparsely and unevenly distributed across this joint phase space, each target slice was reconstructed by interpolating rebinned sinogram rows to the target cardiac phase and respiratory amplitude, using either 2D scattered barycentric interpolation or 2D scattered local linear interpolation with a circular kernel for cardiac phase. Reconstructed volumes were compared to phantom ground truth using mean absolute error (MAE), and to conventional respiratory-gated 4DCT (r4DCT) reconstructed from the same simulated data. Results: Both interpolation methods eliminated the severe axial misalignment artifacts present when helical projections were reconstructed without phase-space interpolation. Local linear interpolation achieved lower MAE than barycentric interpolation across most tested conditions, with the largest improvement at low pitch. The 5DCT pipeline also produced respiratory-only volumes with fewer residual cardiac-motion artifacts than conventional r4DCT reconstructed from the same projection data, including at standard clinical pitch (0.1). Conclusions: 5DCT reconstruction using sinogram-space interpolation is feasible and can jointly resolve cardiac and respiratory motion with better accuracy than conventional 4DCT reconstruction.

physics.med-ph