SearcharxivSearch

arXiv · 2412.10740

IBIC analysis of a linear position sensitive detector: model and experiment

Abstract

The ion beam-induced charge (IBIC) analysis of a commercial silicon photodiode configured as a Position Sensitive Detector (PSD) for energetic charged particles is the subject of this report. Although the photodiode is designed for detecting the position of incident light and optimized for use in the UV region, we present evidence that it also performs well as a detector for ions, with energies in the MeV range. The device consists of a uniform p-type layer formed on a high-resistivity n-type semiconductor substrate, a pair of electrodes on both ends of the resistive layer, and a common electrode located on the backside of the substrate. The IBIC experiment was carried out at the Laboratory for Ion Beam Interaction (LIBI) of the Ruder Boskovic Institute in Zagreb (HR), using 2 MeV proton microbeam raster scanning the 2.5x0.6 mm2 active area of the PSD. Each of the three electrodes was connected to independent standard NIM charge-sensitive electronic chain and the induced charge pulses associated with the position of individual ions were then digitized using a multi-channel analyzer interfaced with the SPECTOR software. The longitudinal Charge Collection Efficiency (CCE) profiles acquired from the top electrodes show linear behaviors with opposite slopes, whereas the profile relevant to the signals from the back electrode is almost constant. A model based on the IBIC theory satisfactorily interprets these results. It offers an alternative viewpoint to the commonly adopted Lateral Effect Photodiode principle and paves the way for the development of new PSDs for the identification of the impact position of a MeV ion with a resolution at the micrometer scale.

Explore related subjects

Keep this discovery

Explore connections, maps & timelines

BibTeXRIS

Ettore Vittone, Georgios Provatas, Karla Ivanković Nizić, Milko Jaksic. 2024-12-14. IBIC analysis of a linear position sensitive detector: model and experiment. https://arxiv.org/abs/2412.10740

Cite the original work for its findings. Save a collection to share your selection of sources.

KEEP EXPLORING

Related papers

High-Speed Semi-FE Readout Module for ATLAS MDT at HL-LHC: Design and Production-Level Characterization

The High-Luminosity upgrade of the Large Hadron Collider (HL-LHC) introduces increased demands on the ATLAS Muon Spectrometer, particularly in terms of data throughput, timing distribution and system reliability. The Phase-II Chamber Service Module (CSM) is a key component of the upgraded Monitored Drift Tube (MDT) trigger and readout system, providing a high-speed interface between the front-end electronics and the backend systems. This paper describes the design and implementation of the Phase-II CSM, together with its validation. The results show that the CSM supports two independent optical uplinks, each operating at a line rate of 10.24 Gbps, together with clock distribution and slow control in the expected operating environment. Integration with small-diameter MDT (sMDT) chambers and tests with the prototype L0MDT trigger system are also presented. The CSM boards are now in production and will be used for installation and integration during the upcoming LHC Long Shutdown.

physics.ins-det

Spectral Discrimination of Deposited Gamma-Ray Energies in a Simulated CeBr$_3$ Scintillator

We show that wavelength measurements of individual detected optical photons may provide additional information about gamma-ray energy deposited in a CeBr$_3$ crystal when the detected-photon-count distributions overlap for nearby gamma-ray energies. Monoenergetic 662 and 629 keV gammas are used in a Geant4 simulation of a $25\times25\times20~\mathrm{mm^3}$ CeBr$_3$ crystal. Assuming a light yield of $6.0\times10^4$ photons/MeV, a wavelength-independent photon-detection efficiency of 30%, and a wavelength resolution of $\sigma_{\lambda}=40$ nm, we find that the fraction of photons reconstructed above 385 nm gives an event-level separation of $\sim$ 2 standard deviations between the 662 and 629 keV event populations selected within the same $\sim$ 1%-wide detected-photon-count interval. No timing or reconstructed interaction-position information is used. The result demonstrates, within the present simulation model, that event-dependent optical spectra can retain energy information beyond an undifferentiated photon count.

physics.ins-det

Operation of a negative ion gas time projection chamber without electronegative fill gases

The high fidelity reconstruction of particle tracks in micropatterned gaseous time projection chambers renders this technology ideal for future rare-event searches, including direction-sensitive dark matter experiments. Large drift distances are typically required for such experiments, so that the overall spatial resolution is limited by diffusion. Negative ion drift exhibits lower diffusion than electron drift and is thus an attractive option for realising a large-scale detector. The use of electronegative gases to create negative ions introduces technical challenges, most notably a reduction in gain when compared to conventional gas mixtures. In this study, we demonstrate a new method for negative ion generation via dissociative electron attachment using the conventional molecular fill gas CF$_4$. Our optical measurements of negative ion drift indicate electron attachment lengths of $<$1 mm and comparable gain to electron avalanches. The individual negative ion avalanches were also time-resolved, allowing the number of ions reaching the readout to be counted. We measure an improved energy resolution by single ion counting, relative to an integrated electron avalanche signal measured under identical gain conditions.

physics.ins-det