SearcharxivSearch

arXiv · 2503.11319

LiquidO: Neutrino Detection and Imaging in Opaque Media

Abstract

For several decades now, scintillator detectors have found a wide range of applications in particle physics, including neutrino detection, the search for dark matter and even medical imaging. These detectors so far have strongly relied on the transparency of the scintillating medium, through which light is typically propagated to surrounding photosensors. In this work, we present the results of a 10 litre prototype based on a novel detection approach where an opaque scintillator medium is used to confine light near its creation point that is then collected by a grid of wavelength-shifting fibres traversing the detector. The prototype is operated with different media, including the novel opaque scintillator NoWaSH whose scattering length varies with temperature. Our results progressively demonstrate the temperature-dependent stochastic confinement of the light, with 90% (80%) of the light being confined within a radius of 5 cm (4 cm) when the scattering length is on the order of a few millimetres. The results also demonstrate the pulse shape resolution of our setup capable of resolving Cherenkov and scintillation light. Altogether, the observations match the performance expected for this new type of detector, whose capabilities are expected to include the imaging of particle interactions down to MeV-energies.

Explore related subjects

Keep this discovery

Explore connections, maps & timelines

BibTeXRIS

Diana Navas-Nicolás, Cloé Girard-Carillo, Stefan Schoppmann. 2025-03-14. LiquidO: Neutrino Detection and Imaging in Opaque Media. https://doi.org/10.22323/1.476.1069

Cite the original work for its findings. Save a collection to share your selection of sources.

KEEP EXPLORING

Related papers

High-Speed Semi-FE Readout Module for ATLAS MDT at HL-LHC: Design and Production-Level Characterization

The High-Luminosity upgrade of the Large Hadron Collider (HL-LHC) introduces increased demands on the ATLAS Muon Spectrometer, particularly in terms of data throughput, timing distribution and system reliability. The Phase-II Chamber Service Module (CSM) is a key component of the upgraded Monitored Drift Tube (MDT) trigger and readout system, providing a high-speed interface between the front-end electronics and the backend systems. This paper describes the design and implementation of the Phase-II CSM, together with its validation. The results show that the CSM supports two independent optical uplinks, each operating at a line rate of 10.24 Gbps, together with clock distribution and slow control in the expected operating environment. Integration with small-diameter MDT (sMDT) chambers and tests with the prototype L0MDT trigger system are also presented. The CSM boards are now in production and will be used for installation and integration during the upcoming LHC Long Shutdown.

physics.ins-det

Spectral Discrimination of Deposited Gamma-Ray Energies in a Simulated CeBr$_3$ Scintillator

We show that wavelength measurements of individual detected optical photons may provide additional information about gamma-ray energy deposited in a CeBr$_3$ crystal when the detected-photon-count distributions overlap for nearby gamma-ray energies. Monoenergetic 662 and 629 keV gammas are used in a Geant4 simulation of a $25\times25\times20~\mathrm{mm^3}$ CeBr$_3$ crystal. Assuming a light yield of $6.0\times10^4$ photons/MeV, a wavelength-independent photon-detection efficiency of 30%, and a wavelength resolution of $\sigma_{\lambda}=40$ nm, we find that the fraction of photons reconstructed above 385 nm gives an event-level separation of $\sim$ 2 standard deviations between the 662 and 629 keV event populations selected within the same $\sim$ 1%-wide detected-photon-count interval. No timing or reconstructed interaction-position information is used. The result demonstrates, within the present simulation model, that event-dependent optical spectra can retain energy information beyond an undifferentiated photon count.

physics.ins-det

Operation of a negative ion gas time projection chamber without electronegative fill gases

The high fidelity reconstruction of particle tracks in micropatterned gaseous time projection chambers renders this technology ideal for future rare-event searches, including direction-sensitive dark matter experiments. Large drift distances are typically required for such experiments, so that the overall spatial resolution is limited by diffusion. Negative ion drift exhibits lower diffusion than electron drift and is thus an attractive option for realising a large-scale detector. The use of electronegative gases to create negative ions introduces technical challenges, most notably a reduction in gain when compared to conventional gas mixtures. In this study, we demonstrate a new method for negative ion generation via dissociative electron attachment using the conventional molecular fill gas CF$_4$. Our optical measurements of negative ion drift indicate electron attachment lengths of $<$1 mm and comparable gain to electron avalanches. The individual negative ion avalanches were also time-resolved, allowing the number of ions reaching the readout to be counted. We measure an improved energy resolution by single ion counting, relative to an integrated electron avalanche signal measured under identical gain conditions.

physics.ins-det