SearcharxivSearch

arXiv · 2503.20022

Picosecond Josephson Samplers: Modeling and Measurements

Abstract

Measurement of signals generated by superconducting Josephson junction (JJ) circuits require ultra-fast components located in close proximity to the generating circuitry. We report a detailed study of optimal design criteria for a JJ-based sampler which balances the highest sampler bandwidth (shortest 10\%--90\% rise time) with minimal sampled waveform distortion. We explore the impacts on performance of a sampler, realized using a single underdamped JJ as the logical sampling element (the comparator), due to the type of signal-comparator coupling scheme that is utilized (galvanic, inductive, or capacitive). In these simulations we emulate the entire waveform reconstruction sampling process, via comparator threshold detection, while sweeping the time location at which the waveform is being sampled. We extract the sampled waveform rise time (or FWHM) as a function of the comparator's Stewart-McCumber parameter and as a function of the coupling strength between the device under test and comparator. Based on our simulation results we design, fabricate, and characterize a cryocooled (3.6 K operating temperature) JJ sampler utilizing the NIST state-of-the-art Nb/amorphous-Si/Nb junctions. We separately sample a step signal and impulse generator co-located on-chip with the comparator and sampling strobe generator by implementing the same binary search comparator threshold detection technique during sampler operation as is used in simulation. With this technique the system is fully-digital and automated and operation of the fabricated device directly mirrors simulation. Our sampler technology shows a 10\%--90\% rise time of 3.3 ps and the capability to measure transient pulse widths of 2.5 ps FWHM. A linear systems analysis of sampled waveforms indicate a 3 dB bandwidth of 225 GHz, but we demonstrate effective measurement of signals well above this -- as high as 600 GHz.

Explore related subjects

Keep this discovery

BibTeXRIS

Logan Howe, Bart van Zeghbroeck, David Olaya, John Biesecker, Charles J. Burroughs, Samuel P. Benz, Peter F. Hopkins. 2025-03-25. Picosecond Josephson Samplers: Modeling and Measurements. https://arxiv.org/abs/2503.20022

Cite the original work for its findings. Save a collection to share your selection of sources.

KEEP EXPLORING

Related papers

High-Speed Semi-FE Readout Module for ATLAS MDT at HL-LHC: Design and Production-Level Characterization

The High-Luminosity upgrade of the Large Hadron Collider (HL-LHC) introduces increased demands on the ATLAS Muon Spectrometer, particularly in terms of data throughput, timing distribution and system reliability. The Phase-II Chamber Service Module (CSM) is a key component of the upgraded Monitored Drift Tube (MDT) trigger and readout system, providing a high-speed interface between the front-end electronics and the backend systems. This paper describes the design and implementation of the Phase-II CSM, together with its validation. The results show that the CSM supports two independent optical uplinks, each operating at a line rate of 10.24 Gbps, together with clock distribution and slow control in the expected operating environment. Integration with small-diameter MDT (sMDT) chambers and tests with the prototype L0MDT trigger system are also presented. The CSM boards are now in production and will be used for installation and integration during the upcoming LHC Long Shutdown.

physics.ins-det

Spectral Discrimination of Deposited Gamma-Ray Energies in a Simulated CeBr$_3$ Scintillator

We show that wavelength measurements of individual detected optical photons may provide additional information about gamma-ray energy deposited in a CeBr$_3$ crystal when the detected-photon-count distributions overlap for nearby gamma-ray energies. Monoenergetic 662 and 629 keV gammas are used in a Geant4 simulation of a $25\times25\times20~\mathrm{mm^3}$ CeBr$_3$ crystal. Assuming a light yield of $6.0\times10^4$ photons/MeV, a wavelength-independent photon-detection efficiency of 30%, and a wavelength resolution of $\sigma_{\lambda}=40$ nm, we find that the fraction of photons reconstructed above 385 nm gives an event-level separation of $\sim$ 2 standard deviations between the 662 and 629 keV event populations selected within the same $\sim$ 1%-wide detected-photon-count interval. No timing or reconstructed interaction-position information is used. The result demonstrates, within the present simulation model, that event-dependent optical spectra can retain energy information beyond an undifferentiated photon count.

physics.ins-det

Operation of a negative ion gas time projection chamber without electronegative fill gases

The high fidelity reconstruction of particle tracks in micropatterned gaseous time projection chambers renders this technology ideal for future rare-event searches, including direction-sensitive dark matter experiments. Large drift distances are typically required for such experiments, so that the overall spatial resolution is limited by diffusion. Negative ion drift exhibits lower diffusion than electron drift and is thus an attractive option for realising a large-scale detector. The use of electronegative gases to create negative ions introduces technical challenges, most notably a reduction in gain when compared to conventional gas mixtures. In this study, we demonstrate a new method for negative ion generation via dissociative electron attachment using the conventional molecular fill gas CF$_4$. Our optical measurements of negative ion drift indicate electron attachment lengths of $<$1 mm and comparable gain to electron avalanches. The individual negative ion avalanches were also time-resolved, allowing the number of ions reaching the readout to be counted. We measure an improved energy resolution by single ion counting, relative to an integrated electron avalanche signal measured under identical gain conditions.

physics.ins-det