SearcharxivSearch

arXiv · 2504.08931

Heatpipe-cooled in-vacuum electromagnet for quantum science experiment

Abstract

Quantum inertial sensors test general relativity, measure fundamental constants, and probe dark matter and dark energy in the laboratory with outstanding accuracy. Their precision relies heavily on carefully choreographed quantum control of the atomic states with a collection of lasers, microwaves, electric and magnetic fields. Making this technology available outside of the laboratory would unlock many applications, such as geophysics, geodesy and inertial navigation. However, this requires an apparatus of reduced size, weight, power use and increased robustness, modularity and ease-of-use. Here, we describe the design and implementation of an in-vacuum electromagnet able to create the magnetic fields necessary for various quantum control operations, such as magneto-optical trapping or magnetic levitation to assist evaporative cooling. Placing the electromagnet inside the vacuum chamber has significant advantages, such as fast switching times that are not limited by induced current inside the vacuum chamber metal, reduced size, weight and power usage. However, dissipating the heat produced typically requires complex designs that include bulky metal heatsinks or cooling using water or cryogens. Our design implements heatpipes in a compact, low-vibration and robust apparatus, which use a phase transition in the working fluid to achieve thermal conductivity that is more than one hundred times larger than that of typical bulk metal. We show that the setup can conduct more than 50 W of thermal power in a configuration that provides ample optical access and is compatible with the ultra-high vacuum requirements of atomic and molecular experiments.

Explore related subjects

Keep this discovery

Explore connections, maps & timelines

BibTeXRIS

Kenneth Nakasone, Paola Luna, Andrei Zhukov, Matthew Tao, Garrett Louie, Cristian D. Panda. 2025-04-11. Heatpipe-cooled in-vacuum electromagnet for quantum science experiment. https://arxiv.org/abs/2504.08931

Cite the original work for its findings. Save a collection to share your selection of sources.

KEEP EXPLORING

Related papers

Delay-engineered dynamical phases in a programmable non-Markovian spin oscillator

Non-Markovian dynamics offer a new route towards engineering non-equilibrium matter, where memory and feedback act as programmable resources for controlling order in time. Here we report the realization of a non-Markovian spin oscillator in a hot vapour $^{129}$Xe-Cs co-magnetometer with programmable feedback delay and gain. By tuning these parameters, we observe a hierarchy of dynamical phases, including time-crystalline response, nonlinear bifurcations, and frequency-comb formation. The measured spectra and phase boundaries are captured by linear stability analysis of delayed Bloch equations, revealing these phenomena as different manifestations of the same memory-induced instability structure. These results establish time-delayed feedback as a powerful strategy for controlling non-equilibrium phases, enabling quantum sensing, frequency referencing, and synchronization within a single spin-based platform.

physics.atom-ph

Non-stick vacuum wall collisions with a laser-coolable molecule

Molecular species that are suitable for direct laser cooling are typically considered lost or destroyed if they collide with an ambient temperature vacuum wall. Here, we study surface collisions with aluminum monofluoride (AlF), a laser-coolable molecule that survives this process with unusually high probability. We detect the outgoing AlF molecules from a single wall collision via Doppler-sensitive laser-induced fluorescence spectroscopy, using incoming supersonic (pulsed) and thermochemical (continuous) molecular beams. The angular, velocity and rovibrational level distributions of the outgoing molecules show near-complete thermalisation to the wall in a single collision event. We determine an upper limit to the surface residence time of about 5$~\mu$s, and by monitoring the decay in density of pulses of molecules loaded into a small storage volume, we deduce the surface sticking probability for different materials. For a siloxane-coated metallic surface, the sticking probability of AlF is about 0.015, allowing us to accumulate molecules from the thermochemical source into an ambient temperature storage vessel at densities near $10^{8}~$cm$^{-3}$. This provides a route to compact, portable traps for neutral molecules.

physics.atom-ph

Kinetic modeling of molecular beam formation in a cryogenic buffer-gas cell

Cryogenic buffer-gas cells are widely used to produce cold molecular beams, but the microscopic dynamics governing beam formation remain challenging to model. Here we present fully kinetic simulations of a cryogenic buffer-gas cell using the Direct Simulation Monte Carlo method implemented in the PICLas framework, treating the buffer gas and ablated molecules within a single unified model. We capture characteristic features of cryogenic buffer-gas sources, including plume cooling, directed transport toward the aperture, and the formation of a slow molecular beam, while also resolving energy transfer from the hot ablation plume to the helium buffer gas that is inaccessible to existing approaches relying on the background-gas approximation. Our results demonstrate that fully kinetic simulations can provide detailed insights into buffer-gas cell dynamics and open a route toward a systematic optimization of such sources.

physics.atom-ph