Evidence of localized groundwater flow during thermal response test using distributed thermal sensing

Abstract

Four Borehole Heat Exchangers (BHE) were installed at the BRGM Shallow Geothermal Research Facility (BRGM-SGRF) in Orl{\'e}ans, France. They are sixty meters deep and eight meters apart on a line. The facility is localized in the Parisian sedimentary basin. The boreholes are in the Beauce Limestones geological layers, which are locally eroded and karstified. A special type of grouting materiel was used in order to investigate if the boreholes are actually grouted. These measures have confirmed that the four boreholes are grouted along the whole depth. Distributed Thermal Response Tests (DTRT) using optic cables alongside the heat exchangers were performed on each borehole. The distributed thermal sensing, combined with the thermal response test, allows discriminating the heat transfer between geological layers. While the first two boreholes temperature variations with respect to the depth is almost constant, again indicative of a purely conductive heat transfer, the DTS measurement technique gave evidence of a localized enhanced heat transfer on the last two boreholes, between 25 and 40 meters deep. This enhanced heat transfer is believed to be generated by a fast groundwater flow at these depths. What is remarkable is that such a rapid flow can be observed on roughly 15 meters height, while a borehole 8 meters apart exhibits a purely conductive temperature profile. The BRGM has develop a borehole heat exchanger model called SAMBA (Semi Analytical Model for Borehole heat exchanger). It discretizes the heat transfer according to the depth of the borehole, using the thermal resistance and capacity model of Bauer et al. (2011) to model heat transfer inside the borehole, and a moving infinite cylindrical source (MICS) for heat transfer in the ground. Inversion of the SAMBA model for the boreholes exhibiting groundwater flow has been performed to determine the mean ground thermal conductivity and the groundwater flow between 25 to 40 meters deep.

Explore related subjects

Keep this discovery

BibTeXRIS

Antoine Voirand, Charles Maragna. 2025-05-13. Evidence of localized groundwater flow during thermal response test using distributed thermal sensing. https://arxiv.org/abs/2505.08564

Cite the original work for its findings. Save a collection to share your selection of sources.

KEEP EXPLORING

Related papers

High-Speed Semi-FE Readout Module for ATLAS MDT at HL-LHC: Design and Production-Level Characterization

The High-Luminosity upgrade of the Large Hadron Collider (HL-LHC) introduces increased demands on the ATLAS Muon Spectrometer, particularly in terms of data throughput, timing distribution and system reliability. The Phase-II Chamber Service Module (CSM) is a key component of the upgraded Monitored Drift Tube (MDT) trigger and readout system, providing a high-speed interface between the front-end electronics and the backend systems. This paper describes the design and implementation of the Phase-II CSM, together with its validation. The results show that the CSM supports two independent optical uplinks, each operating at a line rate of 10.24 Gbps, together with clock distribution and slow control in the expected operating environment. Integration with small-diameter MDT (sMDT) chambers and tests with the prototype L0MDT trigger system are also presented. The CSM boards are now in production and will be used for installation and integration during the upcoming LHC Long Shutdown.

physics.ins-det

Spectral Discrimination of Deposited Gamma-Ray Energies in a Simulated CeBr$_3$ Scintillator

We show that wavelength measurements of individual detected optical photons may provide additional information about gamma-ray energy deposited in a CeBr$_3$ crystal when the detected-photon-count distributions overlap for nearby gamma-ray energies. Monoenergetic 662 and 629 keV gammas are used in a Geant4 simulation of a $25\times25\times20~\mathrm{mm^3}$ CeBr$_3$ crystal. Assuming a light yield of $6.0\times10^4$ photons/MeV, a wavelength-independent photon-detection efficiency of 30%, and a wavelength resolution of $\sigma_{\lambda}=40$ nm, we find that the fraction of photons reconstructed above 385 nm gives an event-level separation of $\sim$ 2 standard deviations between the 662 and 629 keV event populations selected within the same $\sim$ 1%-wide detected-photon-count interval. No timing or reconstructed interaction-position information is used. The result demonstrates, within the present simulation model, that event-dependent optical spectra can retain energy information beyond an undifferentiated photon count.

physics.ins-det

Operation of a negative ion gas time projection chamber without electronegative fill gases

The high fidelity reconstruction of particle tracks in micropatterned gaseous time projection chambers renders this technology ideal for future rare-event searches, including direction-sensitive dark matter experiments. Large drift distances are typically required for such experiments, so that the overall spatial resolution is limited by diffusion. Negative ion drift exhibits lower diffusion than electron drift and is thus an attractive option for realising a large-scale detector. The use of electronegative gases to create negative ions introduces technical challenges, most notably a reduction in gain when compared to conventional gas mixtures. In this study, we demonstrate a new method for negative ion generation via dissociative electron attachment using the conventional molecular fill gas CF$_4$. Our optical measurements of negative ion drift indicate electron attachment lengths of $<$1 mm and comparable gain to electron avalanches. The individual negative ion avalanches were also time-resolved, allowing the number of ions reaching the readout to be counted. We measure an improved energy resolution by single ion counting, relative to an integrated electron avalanche signal measured under identical gain conditions.

physics.ins-det