SearcharxivSearch

arXiv · 2507.03790

Upscaling the hyperpolarization sample volume of an automated hydrogenative parahydrogen-induced polarizer

Abstract

Nuclear magnetic resonance (NMR) and magnetic resonance imaging (MRI) suffer from inherently low sensitivity due to the weak thermal polarization of nuclear spins. Parahydrogen-induced polarization (PHIP) offers a powerful route to enhance NMR signals by several orders of magnitude, enabling real-time metabolic imaging. However, PHIP implementations are often constrained by small sample volumes, limited automation, and complex high-pressure requirements. In this work, we present an upgraded, automated PHIP system capable of hyperpolarizing sample volumes of up to 2.2 mL, making it suitable for preclinical MRI applications. We developed several high-pressure reactors and multi-port NMR tube caps compatible with standard commercial 5, 10, and 16 mm glass tubes. Reactor designs were simulated and fabricated from chemically resistant polymers, ensuring mechanical safety at more than 30 bar. Using FLASH MRI, nutation, and CPMG sequences, we characterized magnetic field homogeneity and stability, establishing optimal sample dimensions (12.5/16 mm ID/OD glass tube, 20 mm height) with B0 inhomogeneity below 2.5 ppm and B1 inhomogeneity around 1%. A high level of injection reproducibility was confirmed (volume precision ~0.6%). Optimization of experimental parameters, including hydrogenation pressure, pH2 flow rate, and sample temperature, enabled rapid and efficient polarization transfer. At optimized conditions (20 bar pH2, 2 L/min flow, 55{\deg}C, 4 s bubbling time), up to 31.3% 1H polarization of two protons was achieved for deuterated ethyl acetate in acetone with the theoretical maximum of 50%. This level of polarization was achieved with a duty cycle of 80 s, and the standard deviation of the mean was below 6.8%.

Explore related subjects

Keep this discovery

BibTeXRIS

Yenal Gökpek, Jan-Bernd Hövener, Andrey N. Pravdivtsev. 2025-07-04. Upscaling the hyperpolarization sample volume of an automated hydrogenative parahydrogen-induced polarizer. https://doi.org/10.1021/acsmeasuresciau.5c00097

Cite the original work for its findings. Save a collection to share your selection of sources.

KEEP EXPLORING

Related papers

High-Speed Semi-FE Readout Module for ATLAS MDT at HL-LHC: Design and Production-Level Characterization

The High-Luminosity upgrade of the Large Hadron Collider (HL-LHC) introduces increased demands on the ATLAS Muon Spectrometer, particularly in terms of data throughput, timing distribution and system reliability. The Phase-II Chamber Service Module (CSM) is a key component of the upgraded Monitored Drift Tube (MDT) trigger and readout system, providing a high-speed interface between the front-end electronics and the backend systems. This paper describes the design and implementation of the Phase-II CSM, together with its validation. The results show that the CSM supports two independent optical uplinks, each operating at a line rate of 10.24 Gbps, together with clock distribution and slow control in the expected operating environment. Integration with small-diameter MDT (sMDT) chambers and tests with the prototype L0MDT trigger system are also presented. The CSM boards are now in production and will be used for installation and integration during the upcoming LHC Long Shutdown.

physics.ins-det

Spectral Discrimination of Deposited Gamma-Ray Energies in a Simulated CeBr$_3$ Scintillator

We show that wavelength measurements of individual detected optical photons may provide additional information about gamma-ray energy deposited in a CeBr$_3$ crystal when the detected-photon-count distributions overlap for nearby gamma-ray energies. Monoenergetic 662 and 629 keV gammas are used in a Geant4 simulation of a $25\times25\times20~\mathrm{mm^3}$ CeBr$_3$ crystal. Assuming a light yield of $6.0\times10^4$ photons/MeV, a wavelength-independent photon-detection efficiency of 30%, and a wavelength resolution of $\sigma_{\lambda}=40$ nm, we find that the fraction of photons reconstructed above 385 nm gives an event-level separation of $\sim$ 2 standard deviations between the 662 and 629 keV event populations selected within the same $\sim$ 1%-wide detected-photon-count interval. No timing or reconstructed interaction-position information is used. The result demonstrates, within the present simulation model, that event-dependent optical spectra can retain energy information beyond an undifferentiated photon count.

physics.ins-det

Operation of a negative ion gas time projection chamber without electronegative fill gases

The high fidelity reconstruction of particle tracks in micropatterned gaseous time projection chambers renders this technology ideal for future rare-event searches, including direction-sensitive dark matter experiments. Large drift distances are typically required for such experiments, so that the overall spatial resolution is limited by diffusion. Negative ion drift exhibits lower diffusion than electron drift and is thus an attractive option for realising a large-scale detector. The use of electronegative gases to create negative ions introduces technical challenges, most notably a reduction in gain when compared to conventional gas mixtures. In this study, we demonstrate a new method for negative ion generation via dissociative electron attachment using the conventional molecular fill gas CF$_4$. Our optical measurements of negative ion drift indicate electron attachment lengths of $<$1 mm and comparable gain to electron avalanches. The individual negative ion avalanches were also time-resolved, allowing the number of ions reaching the readout to be counted. We measure an improved energy resolution by single ion counting, relative to an integrated electron avalanche signal measured under identical gain conditions.

physics.ins-det