The Automatic Calibration Method of the Compton Edge Based on Normalized Cross-correlation and Simulated Annealing Algorithm

Abstract

Accurate energy channel calibration in scintillation detectors is essential for reliable radiation detection across nuclear physics, medical imaging, and environmental monitoring. Organic scintillators like BC408 and EJ309 lack full-energy peaks, making their Compton edge a critical calibration alternative where traditional peak methods fail. Existing Compton edge identification techniques - Gaussian fitting for the 50%-70% amplitude point, first derivative minimum detection, and Monte Carlo simulation - suffer significant degradation from low count rates, spectral overlap, and subjective interval selection. For the first time, we propose an automated calibration procedure based on Normalized Cross-Correlation (NCC), Simulated Annealing (SA), and a convolutional response model to address these issues. This method automates the selection of the Compton edge interval through NCC-based matching, utilizes SA for global parameter optimization, and then employs a convolutional model for precise matching. Experiments involving the irradiation of organic scintillators (BC408, EJ309) and inorganic scintillators (NaI:Tl, LaBr3:Ce) with 137Cs, 22Na, 54Mn, and 60Co radiation sources demonstrate that this method achieves accuracy commensurate with full-energy peak calibration method (cosine similarity >99.999%) and exhibits superior stability compared to the two traditional methods. In the extreme cases of spectral overlap and low count rate, the average errors of this method are 19.77% and 15.65% of those from the two traditional methods in BC408, 56.44% and 33.15% of those from the two traditional methods in EJ309. This work advances detector calibration and offers a scalable, automated solution for high-energy experiments and portable devices.

Explore related subjects

Keep this discovery

Explore connections, maps & timelines

BibTeXRIS

Dehua Kong, Yanbiao Zhang, Zixi Lin, Yehao Qiu, Xiulian Chen, Zhonghai Wang. 2025-07-22. The Automatic Calibration Method of the Compton Edge Based on Normalized Cross-correlation and Simulated Annealing Algorithm. https://arxiv.org/abs/2507.16282

Cite the original work for its findings. Save a collection to share your selection of sources.

KEEP EXPLORING

Related papers

High-Speed Semi-FE Readout Module for ATLAS MDT at HL-LHC: Design and Production-Level Characterization

The High-Luminosity upgrade of the Large Hadron Collider (HL-LHC) introduces increased demands on the ATLAS Muon Spectrometer, particularly in terms of data throughput, timing distribution and system reliability. The Phase-II Chamber Service Module (CSM) is a key component of the upgraded Monitored Drift Tube (MDT) trigger and readout system, providing a high-speed interface between the front-end electronics and the backend systems. This paper describes the design and implementation of the Phase-II CSM, together with its validation. The results show that the CSM supports two independent optical uplinks, each operating at a line rate of 10.24 Gbps, together with clock distribution and slow control in the expected operating environment. Integration with small-diameter MDT (sMDT) chambers and tests with the prototype L0MDT trigger system are also presented. The CSM boards are now in production and will be used for installation and integration during the upcoming LHC Long Shutdown.

physics.ins-det

Spectral Discrimination of Deposited Gamma-Ray Energies in a Simulated CeBr$_3$ Scintillator

We show that wavelength measurements of individual detected optical photons may provide additional information about gamma-ray energy deposited in a CeBr$_3$ crystal when the detected-photon-count distributions overlap for nearby gamma-ray energies. Monoenergetic 662 and 629 keV gammas are used in a Geant4 simulation of a $25\times25\times20~\mathrm{mm^3}$ CeBr$_3$ crystal. Assuming a light yield of $6.0\times10^4$ photons/MeV, a wavelength-independent photon-detection efficiency of 30%, and a wavelength resolution of $\sigma_{\lambda}=40$ nm, we find that the fraction of photons reconstructed above 385 nm gives an event-level separation of $\sim$ 2 standard deviations between the 662 and 629 keV event populations selected within the same $\sim$ 1%-wide detected-photon-count interval. No timing or reconstructed interaction-position information is used. The result demonstrates, within the present simulation model, that event-dependent optical spectra can retain energy information beyond an undifferentiated photon count.

physics.ins-det

Operation of a negative ion gas time projection chamber without electronegative fill gases

The high fidelity reconstruction of particle tracks in micropatterned gaseous time projection chambers renders this technology ideal for future rare-event searches, including direction-sensitive dark matter experiments. Large drift distances are typically required for such experiments, so that the overall spatial resolution is limited by diffusion. Negative ion drift exhibits lower diffusion than electron drift and is thus an attractive option for realising a large-scale detector. The use of electronegative gases to create negative ions introduces technical challenges, most notably a reduction in gain when compared to conventional gas mixtures. In this study, we demonstrate a new method for negative ion generation via dissociative electron attachment using the conventional molecular fill gas CF$_4$. Our optical measurements of negative ion drift indicate electron attachment lengths of $<$1 mm and comparable gain to electron avalanches. The individual negative ion avalanches were also time-resolved, allowing the number of ions reaching the readout to be counted. We measure an improved energy resolution by single ion counting, relative to an integrated electron avalanche signal measured under identical gain conditions.

physics.ins-det