SearcharxivSearch

arXiv · 2508.13206

Fine-Tuning Hydrophilic-Hydrophobic Balance in Stimuli-Responsive PEGPNIPAM Micelles for Controlled Drug Delivery

Abstract

Temperature-responsive polymeric micelles have great potential in drug delivery, enhancing therapeutic efficacy while minimizing systemic toxicity. This study investigates the self-assembly of poly(ethylene glycol)-poly(N-isopropylacrylamide) (PEG-PNIPAM) block copolymers as nanocarriers for Doxorubicin (DOX) using coarse-grained molecular dynamics (CG-MD) simulations. We systematically examined the effects of polymer chain length and hydrophilic/hydrophobic balance on micelle formation, stability, and drug encapsulation efficiency. PEG-PNIPAM copolymers self-assembled above the lower critical solution temperature (LCST), forming stable micelles with varying morphologies. Our findings revealed that PEG enhances micelle hydration and stability, while PNIPAM improves drug retention but may hinder controlled release. Increasing PNIPAM or PEG length significantly increased micelle size, with DOX preferentially localizing in the PEG-rich outer shell, enhancing solubility and preventing aggregation. The DOX diffusion coefficient ranged from $10^{-8}$ to $10^{-9}$ cm$^{2}$s$^{-1}$, reflecting drug release dynamics. Structural and thermodynamic analyses confirmed spontaneous DOX encapsulation, with PEG-PNIPAM micelles providing a favorable environment for drug loading. Mean square displacement (MSD), radial distribution function (RDF), and solvent-accessible surface area (SASA) analyses highlighted the role of PEG in controlled drug release and PNIPAM in drug binding. These molecular-level insights underscore the potential of fine-tuning PEG-PNIPAM compositions for enhanced drug delivery, paving the way for precision cancer therapies.

Explore related subjects

Keep this discovery

Explore connections, maps & timelines

BibTeXRIS

Ghazal Jamirad, Mahdi Seif, Abbas Montazeri. 2025-08-16. Fine-Tuning Hydrophilic-Hydrophobic Balance in Stimuli-Responsive PEGPNIPAM Micelles for Controlled Drug Delivery. https://doi.org/10.1016/j.molliq.2025.128239

Cite the original work for its findings. Save a collection to share your selection of sources.

KEEP EXPLORING

Related papers

Phase-contrast micro-CT for intra-operative breast tumour margin assessment using a microfocus x-ray source and photon-counting detector

Objective: Intra-operative tumour margin assessment during breast-conserving surgery requires rapid, high-resolution imaging of excised tissue, allowing the surgical team to take appropriate action within a single operation. This study evaluates a custom propagation-based phase-contrast micro-computed tomography (micro-CT) system designed to meet these clinical constraints without specialised optical elements. Methods: The experimental setup pairs a microfocus x-ray source with a photon-counting detector in a cone-beam geometry. We explore how the spatial coherence of the source can provide propagation-based phase contrast -- with no additional specialised optical elements -- and balance this against maximising the x-ray flux of the cone-beam geometry. System performance was evaluated across two anode target materials and filtration configurations at various tube power settings. Imaging capabilities were validated using anthropomorphic breast tissue phantoms and a formalin-fixed paraffin-embedded (FFPE) breast tissue specimen, with reconstructions compared against gold-standard histology. Results: An unfiltered tungsten target operated at 40 kVp yielded optimal image quality. The optimised system achieved high-resolution CT reconstructions of a 5 cm diameter sample with an isotropic voxel size of 40.7 $\upmu\text{m}$ in a scan time of 12 minutes. Reconstructed volumes demonstrated strong visual correlation with corresponding histology slides. Conclusion: Combining a microfocus source with a photon-counting detector enables high-resolution, phase-contrast micro-CT within a clinically viable timeframe, demonstrating strong potential for intra-operative margin assessment.

physics.med-ph

Understanding Search and Decision Errors in Liver Metastasis Detection and the Effects of Lower Radiation Dose

The detection performance of liver metastases decreases with the reduction of radiation dose, but misses are heterogeneous. Previous eye tracking work has characterized missed metastases into two categories: search errors i.e., the eyes never land on the lesion, and decision errors i.e., the lesion is seen but not recognized as malignant. We integrated three prior reader studies to answer this question. In all studies, radiologists interpreted the same set of 40 contrast enhanced abdominal CT exams containing 91 liver metastases whose locations had been previously marked. In two studies, the workstation recorded their gaze and eye movements. Using eye dwell times, metastases were classified as search-error-dominant (majority of misses had <2 sec gaze time) or decision-error-dominant (>2 sec gaze time). In the third study, exams were interpreted both at 120 and 200 quality reference mAs (QRM) by ten radiologists. The third study did not include eye tracking. Out of 91 liver metastases, we excluded 16 that were never missed in the eye tracking studies and used 75 liver metastases for the present study.

physics.med-ph

Develop and Optimize 5DCT Imaging Simulation and Reconstruction Methods

Purpose: To develop and optimize a 5DCT (3D + cardiac phase + respiratory phase) imaging simulation and reconstruction pipeline, and to compare two sinogram-space interpolation methods for reconstructing images at arbitrary combinations of cardiac and respiratory phase. Methods: Helical CT projections were simulated from the 4D XCAT phantom across a range of cardiac and respiratory motion states, with Poisson and electronic noise added. Ground-truth-matched volumes were generated at 5 cardiac phases and 10 respiratory amplitudes (50 total phase combinations). Because acquired projections are sparsely and unevenly distributed across this joint phase space, each target slice was reconstructed by interpolating rebinned sinogram rows to the target cardiac phase and respiratory amplitude, using either 2D scattered barycentric interpolation or 2D scattered local linear interpolation with a circular kernel for cardiac phase. Reconstructed volumes were compared to phantom ground truth using mean absolute error (MAE), and to conventional respiratory-gated 4DCT (r4DCT) reconstructed from the same simulated data. Results: Both interpolation methods eliminated the severe axial misalignment artifacts present when helical projections were reconstructed without phase-space interpolation. Local linear interpolation achieved lower MAE than barycentric interpolation across most tested conditions, with the largest improvement at low pitch. The 5DCT pipeline also produced respiratory-only volumes with fewer residual cardiac-motion artifacts than conventional r4DCT reconstructed from the same projection data, including at standard clinical pitch (0.1). Conclusions: 5DCT reconstruction using sinogram-space interpolation is feasible and can jointly resolve cardiac and respiratory motion with better accuracy than conventional 4DCT reconstruction.

physics.med-ph