SearcharxivSearch

arXiv · 2509.05851

Organ Dose Conversion Factors for Murine Galactic Cosmic Ray Irradiation

Abstract

Galactic cosmic rays (GCR) are a principal source of ionizing radiation exposure for astronauts during deep space missions. Given the ambition to expand manned space exploration to distant destinations like Mars, it is essential to accurately predict the radiation doses astronauts are likely to encounter and the consequent biological impacts. Accurate dose predictions are important for operational radiation safety, ensuring risk assessments and protective measures are properly calibrated to challenges of deep space travel. The GCRsim facility at the NASA Space Radiation Laboratory enables small animal radiobiology studies of GCR exposure, offering a controlled setting to mimic the complex radiation conditions in deep space. This manuscript introduces Dose Conversion Factors (DCFs) enabling rigorous absorbed dose calculations for mice irradiated at the GCRsim. A formalism was introduced for calculating organ-level and voxel-level radiation dose to a representative mouse phantom, based on DCFs quantifying absorbed dose per unit fluence of different GCRsim species for various irradiation orientations. The PHITS Monte Carlo code was employed to compute the DCFs in units of Gy m^2 ion^-1. A library of murine DCFs was derived using the PHITS Monte Carlo code for six irradiation orientations: right-left, anterior-posterior, superior-inferior, and their opposed variations. Absorbed doses to the murine total body were calculated and compared with ion chamber measurements, which agreed within 10%. A library of dose conversion factors for mouse irradiation at GCRsim was developed and validated against measurements. These DCFs account for organ-specific variations in radiation dose from different GCR species, enabling improved assessments of potential radiogenic effects and enhancing astronaut safety for future deep space missions.

Explore related subjects

Keep this discovery

Explore connections, maps & timelines

BibTeXRIS

S. Hosseini, M. Sivertz, E. M. Alves, L. M. Carter, M. D. Story. 2025-09-06. Organ Dose Conversion Factors for Murine Galactic Cosmic Ray Irradiation. https://arxiv.org/abs/2509.05851

Cite the original work for its findings. Save a collection to share your selection of sources.

KEEP EXPLORING

Related papers

Phase-contrast micro-CT for intra-operative breast tumour margin assessment using a microfocus x-ray source and photon-counting detector

Objective: Intra-operative tumour margin assessment during breast-conserving surgery requires rapid, high-resolution imaging of excised tissue, allowing the surgical team to take appropriate action within a single operation. This study evaluates a custom propagation-based phase-contrast micro-computed tomography (micro-CT) system designed to meet these clinical constraints without specialised optical elements. Methods: The experimental setup pairs a microfocus x-ray source with a photon-counting detector in a cone-beam geometry. We explore how the spatial coherence of the source can provide propagation-based phase contrast -- with no additional specialised optical elements -- and balance this against maximising the x-ray flux of the cone-beam geometry. System performance was evaluated across two anode target materials and filtration configurations at various tube power settings. Imaging capabilities were validated using anthropomorphic breast tissue phantoms and a formalin-fixed paraffin-embedded (FFPE) breast tissue specimen, with reconstructions compared against gold-standard histology. Results: An unfiltered tungsten target operated at 40 kVp yielded optimal image quality. The optimised system achieved high-resolution CT reconstructions of a 5 cm diameter sample with an isotropic voxel size of 40.7 $\upmu\text{m}$ in a scan time of 12 minutes. Reconstructed volumes demonstrated strong visual correlation with corresponding histology slides. Conclusion: Combining a microfocus source with a photon-counting detector enables high-resolution, phase-contrast micro-CT within a clinically viable timeframe, demonstrating strong potential for intra-operative margin assessment.

physics.med-ph

Understanding Search and Decision Errors in Liver Metastasis Detection and the Effects of Lower Radiation Dose

The detection performance of liver metastases decreases with the reduction of radiation dose, but misses are heterogeneous. Previous eye tracking work has characterized missed metastases into two categories: search errors i.e., the eyes never land on the lesion, and decision errors i.e., the lesion is seen but not recognized as malignant. We integrated three prior reader studies to answer this question. In all studies, radiologists interpreted the same set of 40 contrast enhanced abdominal CT exams containing 91 liver metastases whose locations had been previously marked. In two studies, the workstation recorded their gaze and eye movements. Using eye dwell times, metastases were classified as search-error-dominant (majority of misses had <2 sec gaze time) or decision-error-dominant (>2 sec gaze time). In the third study, exams were interpreted both at 120 and 200 quality reference mAs (QRM) by ten radiologists. The third study did not include eye tracking. Out of 91 liver metastases, we excluded 16 that were never missed in the eye tracking studies and used 75 liver metastases for the present study.

physics.med-ph

Develop and Optimize 5DCT Imaging Simulation and Reconstruction Methods

Purpose: To develop and optimize a 5DCT (3D + cardiac phase + respiratory phase) imaging simulation and reconstruction pipeline, and to compare two sinogram-space interpolation methods for reconstructing images at arbitrary combinations of cardiac and respiratory phase. Methods: Helical CT projections were simulated from the 4D XCAT phantom across a range of cardiac and respiratory motion states, with Poisson and electronic noise added. Ground-truth-matched volumes were generated at 5 cardiac phases and 10 respiratory amplitudes (50 total phase combinations). Because acquired projections are sparsely and unevenly distributed across this joint phase space, each target slice was reconstructed by interpolating rebinned sinogram rows to the target cardiac phase and respiratory amplitude, using either 2D scattered barycentric interpolation or 2D scattered local linear interpolation with a circular kernel for cardiac phase. Reconstructed volumes were compared to phantom ground truth using mean absolute error (MAE), and to conventional respiratory-gated 4DCT (r4DCT) reconstructed from the same simulated data. Results: Both interpolation methods eliminated the severe axial misalignment artifacts present when helical projections were reconstructed without phase-space interpolation. Local linear interpolation achieved lower MAE than barycentric interpolation across most tested conditions, with the largest improvement at low pitch. The 5DCT pipeline also produced respiratory-only volumes with fewer residual cardiac-motion artifacts than conventional r4DCT reconstructed from the same projection data, including at standard clinical pitch (0.1). Conclusions: 5DCT reconstruction using sinogram-space interpolation is feasible and can jointly resolve cardiac and respiratory motion with better accuracy than conventional 4DCT reconstruction.

physics.med-ph