High-throughput Parasitic-independent Probe Thermal Resistance Calibration for Robust Thermal Mapping with Scanning Thermal Microscopy

Abstract

Nanostructured materials, critical for thermal management in semiconductor devices, exhibit a strong size dependence in thermal transport. Studying thermal resistance variation across grain boundaries is critical for designing effective thermal interface materials. Frequency-domain Thermoreflectance (FDTR)-based techniques can provide thermal resistance mapping at the micrometer ({\mu}m) scale. Scanning Thermal Microscopy (SThM) enables quantification of local thermal transport with significantly higher spatial resolution (<100 nm). However, challenges in quantifying the raw signal to thermal conductivity and surface sensitivity limit its widespread adoption for understanding nanoscale heat transport and defect-mediated thermal properties in nanostructured films. Here, we introduce a circuit-based probe thermal resistance (R_p) calibration technique independent of parasitic heat pathways, enabling accurate determination of probe heat dissipation and tip temperature rise, thereby allowing extraction of local thermal resistance. SThM achieved sub-100 nm spatial resolution in mapping thermal resistance across a 15 nm-thick Al film deposited via e-beam evaporation on SiO_2 substrate. The thermal resistance maps are converted to thermal conductivity using robust analytical and finite element models that account for tip-sample geometry, lateral heat spreading, and buried interface effects. Gaussian distribution fitting of pixel-level thermal resistance values yields k_Al = 45.1(+4.7/-3.6) W/(m.K) for the ultra-thin Al film (13-15 nm), representing a 5.3-fold reduction from bulk aluminum (237 W/(m.K)). These results agree with published experimental data and theoretical frameworks explaining thickness-dependent heat transport in ultra-thin metallic films.

Explore related subjects

Keep this discovery

BibTeXRIS

Ram Munde, Heng-Ray Chuang, Raisul Islam. 2025-11-13. High-throughput Parasitic-independent Probe Thermal Resistance Calibration for Robust Thermal Mapping with Scanning Thermal Microscopy. https://doi.org/10.1063/5.0312015

Cite the original work for its findings. Save a collection to share your selection of sources.

KEEP EXPLORING

Related papers

High-Speed Semi-FE Readout Module for ATLAS MDT at HL-LHC: Design and Production-Level Characterization

The High-Luminosity upgrade of the Large Hadron Collider (HL-LHC) introduces increased demands on the ATLAS Muon Spectrometer, particularly in terms of data throughput, timing distribution and system reliability. The Phase-II Chamber Service Module (CSM) is a key component of the upgraded Monitored Drift Tube (MDT) trigger and readout system, providing a high-speed interface between the front-end electronics and the backend systems. This paper describes the design and implementation of the Phase-II CSM, together with its validation. The results show that the CSM supports two independent optical uplinks, each operating at a line rate of 10.24 Gbps, together with clock distribution and slow control in the expected operating environment. Integration with small-diameter MDT (sMDT) chambers and tests with the prototype L0MDT trigger system are also presented. The CSM boards are now in production and will be used for installation and integration during the upcoming LHC Long Shutdown.

physics.ins-det

Spectral Discrimination of Deposited Gamma-Ray Energies in a Simulated CeBr$_3$ Scintillator

We show that wavelength measurements of individual detected optical photons may provide additional information about gamma-ray energy deposited in a CeBr$_3$ crystal when the detected-photon-count distributions overlap for nearby gamma-ray energies. Monoenergetic 662 and 629 keV gammas are used in a Geant4 simulation of a $25\times25\times20~\mathrm{mm^3}$ CeBr$_3$ crystal. Assuming a light yield of $6.0\times10^4$ photons/MeV, a wavelength-independent photon-detection efficiency of 30%, and a wavelength resolution of $\sigma_{\lambda}=40$ nm, we find that the fraction of photons reconstructed above 385 nm gives an event-level separation of $\sim$ 2 standard deviations between the 662 and 629 keV event populations selected within the same $\sim$ 1%-wide detected-photon-count interval. No timing or reconstructed interaction-position information is used. The result demonstrates, within the present simulation model, that event-dependent optical spectra can retain energy information beyond an undifferentiated photon count.

physics.ins-det

Operation of a negative ion gas time projection chamber without electronegative fill gases

The high fidelity reconstruction of particle tracks in micropatterned gaseous time projection chambers renders this technology ideal for future rare-event searches, including direction-sensitive dark matter experiments. Large drift distances are typically required for such experiments, so that the overall spatial resolution is limited by diffusion. Negative ion drift exhibits lower diffusion than electron drift and is thus an attractive option for realising a large-scale detector. The use of electronegative gases to create negative ions introduces technical challenges, most notably a reduction in gain when compared to conventional gas mixtures. In this study, we demonstrate a new method for negative ion generation via dissociative electron attachment using the conventional molecular fill gas CF$_4$. Our optical measurements of negative ion drift indicate electron attachment lengths of $<$1 mm and comparable gain to electron avalanches. The individual negative ion avalanches were also time-resolved, allowing the number of ions reaching the readout to be counted. We measure an improved energy resolution by single ion counting, relative to an integrated electron avalanche signal measured under identical gain conditions.

physics.ins-det