A nonlinear multiphysics model for the design validation of the ASTAROTH copper-steel cryogenic chamber

Abstract

Among the global efforts to directly detect dark matter, the only positive claim so far relies on NaI(Tl) crystal detectors, making this technology of particular interest. ASTAROTH is a project aimed at developing the next generation of such detectors by reading out their scintillation light with SiPM matrices operated at cryogenic temperatures. This paper describes the innovative design of the ASTAROTH cryostat, consisting of a double-walled copper-steel cryogenic chamber that cools the detectors by means of a liquid argon bath. The detectors are thermalized in a helium atmosphere at a temperature tunable from 87 to 150 K. The design has been validated in terms of heat transfer efficiency and mechanical stress, developing a nonlinear multiphysics model. The mechanical properties of OFHC copper were experimentally evaluated on dedicated tensile samples. The simulation results show that the structural integrity is guaranteed. At the highest operating temperature, the region with the steepest temperature gradient exhibits stresses that slightly exceed the yield strength of copper (localized strain-hardened condition). Following construction, the cryostat was commissioned and has been in regular operation for over 30 cooling cycles, with no signs of degradation. The temperature can be tuned across the full target range and remains stable within 0.1 K. These results demonstrate that this is a viable design for next-generation dark matter detectors, as well as for a variety of applications requiring uniform and tunable gas-conducted cooling of instrumentation.

Explore related subjects

Keep this discovery

BibTeXRIS

F. Alessandria, F. B. Armani, S. Coelli, D. Cortis, D. D'Angelo, E. Martinenghi, M. Monti, D. Orlandi, M. Sorbi, V. Toso, A. Zani. 2025-11-27. A nonlinear multiphysics model for the design validation of the ASTAROTH copper-steel cryogenic chamber. https://doi.org/10.1088/1748-0221%2F21%2F01%2Fp01038

Cite the original work for its findings. Save a collection to share your selection of sources.

KEEP EXPLORING

Related papers

High-Speed Semi-FE Readout Module for ATLAS MDT at HL-LHC: Design and Production-Level Characterization

The High-Luminosity upgrade of the Large Hadron Collider (HL-LHC) introduces increased demands on the ATLAS Muon Spectrometer, particularly in terms of data throughput, timing distribution and system reliability. The Phase-II Chamber Service Module (CSM) is a key component of the upgraded Monitored Drift Tube (MDT) trigger and readout system, providing a high-speed interface between the front-end electronics and the backend systems. This paper describes the design and implementation of the Phase-II CSM, together with its validation. The results show that the CSM supports two independent optical uplinks, each operating at a line rate of 10.24 Gbps, together with clock distribution and slow control in the expected operating environment. Integration with small-diameter MDT (sMDT) chambers and tests with the prototype L0MDT trigger system are also presented. The CSM boards are now in production and will be used for installation and integration during the upcoming LHC Long Shutdown.

physics.ins-det

Spectral Discrimination of Deposited Gamma-Ray Energies in a Simulated CeBr$_3$ Scintillator

We show that wavelength measurements of individual detected optical photons may provide additional information about gamma-ray energy deposited in a CeBr$_3$ crystal when the detected-photon-count distributions overlap for nearby gamma-ray energies. Monoenergetic 662 and 629 keV gammas are used in a Geant4 simulation of a $25\times25\times20~\mathrm{mm^3}$ CeBr$_3$ crystal. Assuming a light yield of $6.0\times10^4$ photons/MeV, a wavelength-independent photon-detection efficiency of 30%, and a wavelength resolution of $\sigma_{\lambda}=40$ nm, we find that the fraction of photons reconstructed above 385 nm gives an event-level separation of $\sim$ 2 standard deviations between the 662 and 629 keV event populations selected within the same $\sim$ 1%-wide detected-photon-count interval. No timing or reconstructed interaction-position information is used. The result demonstrates, within the present simulation model, that event-dependent optical spectra can retain energy information beyond an undifferentiated photon count.

physics.ins-det

Operation of a negative ion gas time projection chamber without electronegative fill gases

The high fidelity reconstruction of particle tracks in micropatterned gaseous time projection chambers renders this technology ideal for future rare-event searches, including direction-sensitive dark matter experiments. Large drift distances are typically required for such experiments, so that the overall spatial resolution is limited by diffusion. Negative ion drift exhibits lower diffusion than electron drift and is thus an attractive option for realising a large-scale detector. The use of electronegative gases to create negative ions introduces technical challenges, most notably a reduction in gain when compared to conventional gas mixtures. In this study, we demonstrate a new method for negative ion generation via dissociative electron attachment using the conventional molecular fill gas CF$_4$. Our optical measurements of negative ion drift indicate electron attachment lengths of $<$1 mm and comparable gain to electron avalanches. The individual negative ion avalanches were also time-resolved, allowing the number of ions reaching the readout to be counted. We measure an improved energy resolution by single ion counting, relative to an integrated electron avalanche signal measured under identical gain conditions.

physics.ins-det