Discovery and rectification of an error in high resistance traceability at NPL: a case study in how metrology works

Abstract

We broach a seldom-discussed topic in precision metrology; how subtle errors in calibration processes are discovered and remedied. We examine a case study at the National Physical Laboratory (NPL), UK, involving the calibration of DC standard resistors of value 100 MOhm and 1 GOhm. Results from the period 2001 to 2015 were in error by approximately 0.7 parts per million (ppm), with quoted uncertainties (k=2) of 0.4 ppm and 1.6 ppm respectively. Inter-comparisons did not detect the error, mainly because the uncertainty due to the transportation drift of the comparison standards was too large to resolve it. Likewise, research into single-electron current standards did not detect the error because at this resistance value it was on the borderline of statistical significance. The key event was a comparison between PTB (Germany) and NPL (UK) of a new small-current measuring instrument, the ultrastable low-noise current amplifier (ULCA). At that time, the transport stability of the ULCA was not well established. Nevertheless, calibrations of the ULCA at NPL using a 100 MOhm resistor were sufficiently discrepant with the PTB calibrations to motivate a thorough investigation into the NPL traceability chain, which uncovered the error. This instructive episode illustrates a positive interplay between calibration and research activities and shows that cutting-edge calibration uncertainties must be supported by a vigorous research programme. It is also important for NMIs to maintain a comfortable buffer (at least a factor of 10) between their claimed uncertainty and the uncertainty that their customers require, so that small errors can be resolved without significant impact on measurement stakeholders.

Explore related subjects

Keep this discovery

BibTeXRIS

Stephen Giblin. 2025-12-02. Discovery and rectification of an error in high resistance traceability at NPL: a case study in how metrology works. https://arxiv.org/abs/2512.02887

Cite the original work for its findings. Save a collection to share your selection of sources.

KEEP EXPLORING

Related papers

High-Speed Semi-FE Readout Module for ATLAS MDT at HL-LHC: Design and Production-Level Characterization

The High-Luminosity upgrade of the Large Hadron Collider (HL-LHC) introduces increased demands on the ATLAS Muon Spectrometer, particularly in terms of data throughput, timing distribution and system reliability. The Phase-II Chamber Service Module (CSM) is a key component of the upgraded Monitored Drift Tube (MDT) trigger and readout system, providing a high-speed interface between the front-end electronics and the backend systems. This paper describes the design and implementation of the Phase-II CSM, together with its validation. The results show that the CSM supports two independent optical uplinks, each operating at a line rate of 10.24 Gbps, together with clock distribution and slow control in the expected operating environment. Integration with small-diameter MDT (sMDT) chambers and tests with the prototype L0MDT trigger system are also presented. The CSM boards are now in production and will be used for installation and integration during the upcoming LHC Long Shutdown.

physics.ins-det

Spectral Discrimination of Deposited Gamma-Ray Energies in a Simulated CeBr$_3$ Scintillator

We show that wavelength measurements of individual detected optical photons may provide additional information about gamma-ray energy deposited in a CeBr$_3$ crystal when the detected-photon-count distributions overlap for nearby gamma-ray energies. Monoenergetic 662 and 629 keV gammas are used in a Geant4 simulation of a $25\times25\times20~\mathrm{mm^3}$ CeBr$_3$ crystal. Assuming a light yield of $6.0\times10^4$ photons/MeV, a wavelength-independent photon-detection efficiency of 30%, and a wavelength resolution of $\sigma_{\lambda}=40$ nm, we find that the fraction of photons reconstructed above 385 nm gives an event-level separation of $\sim$ 2 standard deviations between the 662 and 629 keV event populations selected within the same $\sim$ 1%-wide detected-photon-count interval. No timing or reconstructed interaction-position information is used. The result demonstrates, within the present simulation model, that event-dependent optical spectra can retain energy information beyond an undifferentiated photon count.

physics.ins-det

Operation of a negative ion gas time projection chamber without electronegative fill gases

The high fidelity reconstruction of particle tracks in micropatterned gaseous time projection chambers renders this technology ideal for future rare-event searches, including direction-sensitive dark matter experiments. Large drift distances are typically required for such experiments, so that the overall spatial resolution is limited by diffusion. Negative ion drift exhibits lower diffusion than electron drift and is thus an attractive option for realising a large-scale detector. The use of electronegative gases to create negative ions introduces technical challenges, most notably a reduction in gain when compared to conventional gas mixtures. In this study, we demonstrate a new method for negative ion generation via dissociative electron attachment using the conventional molecular fill gas CF$_4$. Our optical measurements of negative ion drift indicate electron attachment lengths of $<$1 mm and comparable gain to electron avalanches. The individual negative ion avalanches were also time-resolved, allowing the number of ions reaching the readout to be counted. We measure an improved energy resolution by single ion counting, relative to an integrated electron avalanche signal measured under identical gain conditions.

physics.ins-det