SearcharxivSearch

arXiv · 2512.11017

Integrating Uncertainty Quantification into Computational Fluid Dynamics Models of Coronary Arteries Under Steady Flow

Abstract

Computational models are continuously integrated in the clinical space, where they support clinicians in disease diagnosis, prognosis, and prevention strategies. While assisting in clinical space, these computational models frequently use deterministic approaches, where the inherent (aleatoric) variability of input parameters is ignored. This questions the credibility and often hinders the clinical adoption of these computational models. Therefore, in this study, we introduced uncertainty quantification in the computational fluid dynamics models of the left main coronary artery to analyze the influence of input hemodynamics parameters on wall shear stress (WSS). UncertainSCI was used, where an emulator was built using polynomial chaos expansion between the input parameters and the output quantity of interest, and the output sensitivities and statistics were directly extracted from the emulator. The uncertainty-informed framework was first applied to an analytical solution of the Navier-Stokes equation (Poiseuille flow) and then to a patient-specific model of the left main coronary artery. Different input hemodynamics parameters are considered, such as pressure, viscosity, density, velocity, and radius, whereas wall shear stress was considered as our output quantity of interest. The results suggest that velocity dominated the variability in WSS in the analytical model (~79%), whereas viscosity dominated in the patient-specific model (~59%). The results further suggest that out of all the Sobol indices interactions, unary interactions were the most dominant ones, contributing ~93.2% and ~99% for the analytical and patient-specific model, respectively. This study will enhance confidence in computational models, facilitating their adoption in the clinical space to improve decision-making for coronary artery disease diagnosis, prognosis, and therapeutic strategies.

Explore related subjects

Keep this discovery

Explore connections, maps & timelines

BibTeXRIS

Muhammad Usman, Peter N. Castillo, Akil Narayan, Lucas H. Timmins. 2025-12-11. Integrating Uncertainty Quantification into Computational Fluid Dynamics Models of Coronary Arteries Under Steady Flow. https://doi.org/10.1115/1.4071773

Cite the original work for its findings. Save a collection to share your selection of sources.

KEEP EXPLORING

Related papers

Phase-contrast micro-CT for intra-operative breast tumour margin assessment using a microfocus x-ray source and photon-counting detector

Objective: Intra-operative tumour margin assessment during breast-conserving surgery requires rapid, high-resolution imaging of excised tissue, allowing the surgical team to take appropriate action within a single operation. This study evaluates a custom propagation-based phase-contrast micro-computed tomography (micro-CT) system designed to meet these clinical constraints without specialised optical elements. Methods: The experimental setup pairs a microfocus x-ray source with a photon-counting detector in a cone-beam geometry. We explore how the spatial coherence of the source can provide propagation-based phase contrast -- with no additional specialised optical elements -- and balance this against maximising the x-ray flux of the cone-beam geometry. System performance was evaluated across two anode target materials and filtration configurations at various tube power settings. Imaging capabilities were validated using anthropomorphic breast tissue phantoms and a formalin-fixed paraffin-embedded (FFPE) breast tissue specimen, with reconstructions compared against gold-standard histology. Results: An unfiltered tungsten target operated at 40 kVp yielded optimal image quality. The optimised system achieved high-resolution CT reconstructions of a 5 cm diameter sample with an isotropic voxel size of 40.7 $\upmu\text{m}$ in a scan time of 12 minutes. Reconstructed volumes demonstrated strong visual correlation with corresponding histology slides. Conclusion: Combining a microfocus source with a photon-counting detector enables high-resolution, phase-contrast micro-CT within a clinically viable timeframe, demonstrating strong potential for intra-operative margin assessment.

physics.med-ph

Understanding Search and Decision Errors in Liver Metastasis Detection and the Effects of Lower Radiation Dose

The detection performance of liver metastases decreases with the reduction of radiation dose, but misses are heterogeneous. Previous eye tracking work has characterized missed metastases into two categories: search errors i.e., the eyes never land on the lesion, and decision errors i.e., the lesion is seen but not recognized as malignant. We integrated three prior reader studies to answer this question. In all studies, radiologists interpreted the same set of 40 contrast enhanced abdominal CT exams containing 91 liver metastases whose locations had been previously marked. In two studies, the workstation recorded their gaze and eye movements. Using eye dwell times, metastases were classified as search-error-dominant (majority of misses had <2 sec gaze time) or decision-error-dominant (>2 sec gaze time). In the third study, exams were interpreted both at 120 and 200 quality reference mAs (QRM) by ten radiologists. The third study did not include eye tracking. Out of 91 liver metastases, we excluded 16 that were never missed in the eye tracking studies and used 75 liver metastases for the present study.

physics.med-ph

Develop and Optimize 5DCT Imaging Simulation and Reconstruction Methods

Purpose: To develop and optimize a 5DCT (3D + cardiac phase + respiratory phase) imaging simulation and reconstruction pipeline, and to compare two sinogram-space interpolation methods for reconstructing images at arbitrary combinations of cardiac and respiratory phase. Methods: Helical CT projections were simulated from the 4D XCAT phantom across a range of cardiac and respiratory motion states, with Poisson and electronic noise added. Ground-truth-matched volumes were generated at 5 cardiac phases and 10 respiratory amplitudes (50 total phase combinations). Because acquired projections are sparsely and unevenly distributed across this joint phase space, each target slice was reconstructed by interpolating rebinned sinogram rows to the target cardiac phase and respiratory amplitude, using either 2D scattered barycentric interpolation or 2D scattered local linear interpolation with a circular kernel for cardiac phase. Reconstructed volumes were compared to phantom ground truth using mean absolute error (MAE), and to conventional respiratory-gated 4DCT (r4DCT) reconstructed from the same simulated data. Results: Both interpolation methods eliminated the severe axial misalignment artifacts present when helical projections were reconstructed without phase-space interpolation. Local linear interpolation achieved lower MAE than barycentric interpolation across most tested conditions, with the largest improvement at low pitch. The 5DCT pipeline also produced respiratory-only volumes with fewer residual cardiac-motion artifacts than conventional r4DCT reconstructed from the same projection data, including at standard clinical pitch (0.1). Conclusions: 5DCT reconstruction using sinogram-space interpolation is feasible and can jointly resolve cardiac and respiratory motion with better accuracy than conventional 4DCT reconstruction.

physics.med-ph