SearcharxivSearch

arXiv · 2601.08644

Percentile-based probabilistic optimization for systematic and random uncertainties in radiation therapy

Abstract

Geometric uncertainty can degrade treatment quality in radiation therapy. While margins and robust optimization mitigate these effects, they provide only implicit control over clinical goal fulfillment probability. We therefore develop a probabilistic planning framework using a percentile-based optimization function that targets a specified probability of clinical goal fulfillment. Systematic and random uncertainties were explicitly modeled over full treatment courses. A scenario dose approximation method based on interpolation between a fixed set of doses was used, enabling efficient simulation of treatment courses during optimization. The framework was evaluated on a prostate case treated with volumetric-modulated arc therapy (VMAT) and a brain case treated with pencil beam scanning (PBS) proton therapy. Plans were compared to conventional margin-based and worst-case robust optimization using probabilistic evaluation. For the prostate case, probabilistic optimization improved organ at risk (OAR) sparing while maintaining target coverage compared to margin-based planning, increasing average OAR goal fulfillment probability by 13.3 percentage points and reducing 90th percentile OAR doses by an average of 3.5~Gy. For the brain case, probabilistic optimization improved target minimum dose passing probabilities (e.g., 88\% vs.~22\% for $D_{95}$) and brainstem maximum dose passing probability (70\% vs.~30\%), while maintaining comparable or improved OAR sparing compared to worst-case optimization. Probabilistic optimization enables explicit and interpretable control over goal fulfillment probabilities. Combining full treatment course modeling with efficient approximate dose calculation, the proposed framework improved the trade-off between target coverage and OAR sparing compared to conventional planning approaches in both photon and proton therapy.

Explore related subjects

Keep this discovery

BibTeXRIS

Albin Fredriksson, Erik Engwall, Jenneke de Jong, Johan Sundström. 2026-01-13. Percentile-based probabilistic optimization for systematic and random uncertainties in radiation therapy. https://arxiv.org/abs/2601.08644

Cite the original work for its findings. Save a collection to share your selection of sources.

KEEP EXPLORING

Related papers

Phase-contrast micro-CT for intra-operative breast tumour margin assessment using a microfocus x-ray source and photon-counting detector

Objective: Intra-operative tumour margin assessment during breast-conserving surgery requires rapid, high-resolution imaging of excised tissue, allowing the surgical team to take appropriate action within a single operation. This study evaluates a custom propagation-based phase-contrast micro-computed tomography (micro-CT) system designed to meet these clinical constraints without specialised optical elements. Methods: The experimental setup pairs a microfocus x-ray source with a photon-counting detector in a cone-beam geometry. We explore how the spatial coherence of the source can provide propagation-based phase contrast -- with no additional specialised optical elements -- and balance this against maximising the x-ray flux of the cone-beam geometry. System performance was evaluated across two anode target materials and filtration configurations at various tube power settings. Imaging capabilities were validated using anthropomorphic breast tissue phantoms and a formalin-fixed paraffin-embedded (FFPE) breast tissue specimen, with reconstructions compared against gold-standard histology. Results: An unfiltered tungsten target operated at 40 kVp yielded optimal image quality. The optimised system achieved high-resolution CT reconstructions of a 5 cm diameter sample with an isotropic voxel size of 40.7 $\upmu\text{m}$ in a scan time of 12 minutes. Reconstructed volumes demonstrated strong visual correlation with corresponding histology slides. Conclusion: Combining a microfocus source with a photon-counting detector enables high-resolution, phase-contrast micro-CT within a clinically viable timeframe, demonstrating strong potential for intra-operative margin assessment.

physics.med-ph

Understanding Search and Decision Errors in Liver Metastasis Detection and the Effects of Lower Radiation Dose

The detection performance of liver metastases decreases with the reduction of radiation dose, but misses are heterogeneous. Previous eye tracking work has characterized missed metastases into two categories: search errors i.e., the eyes never land on the lesion, and decision errors i.e., the lesion is seen but not recognized as malignant. We integrated three prior reader studies to answer this question. In all studies, radiologists interpreted the same set of 40 contrast enhanced abdominal CT exams containing 91 liver metastases whose locations had been previously marked. In two studies, the workstation recorded their gaze and eye movements. Using eye dwell times, metastases were classified as search-error-dominant (majority of misses had <2 sec gaze time) or decision-error-dominant (>2 sec gaze time). In the third study, exams were interpreted both at 120 and 200 quality reference mAs (QRM) by ten radiologists. The third study did not include eye tracking. Out of 91 liver metastases, we excluded 16 that were never missed in the eye tracking studies and used 75 liver metastases for the present study.

physics.med-ph

Develop and Optimize 5DCT Imaging Simulation and Reconstruction Methods

Purpose: To develop and optimize a 5DCT (3D + cardiac phase + respiratory phase) imaging simulation and reconstruction pipeline, and to compare two sinogram-space interpolation methods for reconstructing images at arbitrary combinations of cardiac and respiratory phase. Methods: Helical CT projections were simulated from the 4D XCAT phantom across a range of cardiac and respiratory motion states, with Poisson and electronic noise added. Ground-truth-matched volumes were generated at 5 cardiac phases and 10 respiratory amplitudes (50 total phase combinations). Because acquired projections are sparsely and unevenly distributed across this joint phase space, each target slice was reconstructed by interpolating rebinned sinogram rows to the target cardiac phase and respiratory amplitude, using either 2D scattered barycentric interpolation or 2D scattered local linear interpolation with a circular kernel for cardiac phase. Reconstructed volumes were compared to phantom ground truth using mean absolute error (MAE), and to conventional respiratory-gated 4DCT (r4DCT) reconstructed from the same simulated data. Results: Both interpolation methods eliminated the severe axial misalignment artifacts present when helical projections were reconstructed without phase-space interpolation. Local linear interpolation achieved lower MAE than barycentric interpolation across most tested conditions, with the largest improvement at low pitch. The 5DCT pipeline also produced respiratory-only volumes with fewer residual cardiac-motion artifacts than conventional r4DCT reconstructed from the same projection data, including at standard clinical pitch (0.1). Conclusions: 5DCT reconstruction using sinogram-space interpolation is feasible and can jointly resolve cardiac and respiratory motion with better accuracy than conventional 4DCT reconstruction.

physics.med-ph