arXiv · 2601.10363
A compact Optical Liquid Argon Facility at Roma Tre
Abstract
In this paper we present a compact test facility for the measurement of optical properties of liquid argon as scintillator. The setup is under preparation at Roma Tre and it has a volume of 40 L liquid argon, which is liquefied from argon gas with a purity of $\ge 99.9999\%$ vol. To readout the scintillation photons from liquid argon with the highest intensity near 127 nm, we use the vacuum ultraviolet silicon photomultipliers from Hamamatsu. By submerging the photon detectors directly inside the liquid argon, we can eliminate the systematics from the wavelength shifter and light guides which have been commonly used to detect the scintillation photons of liquid argon.
Explore related subjects
Keep this discovery
Hexi Shi, Valerio D'Andrea, Giuseppe Salamanna, Krzysztof Szczepaniec, Diego Tagnani. 2026-01-15. A compact Optical Liquid Argon Facility at Roma Tre. https://arxiv.org/abs/2601.10363
Cite the original work for its findings. Save a collection to share your selection of sources.