SearcharxivSearch

arXiv · 2602.00336

Inter-detector differential fuzz testing for tamper detection in gamma spectrometers

Abstract

We extend physical differential fuzz testing as an anti-tamper method for radiation detectors [Vavrek et al., Science and Global Security 2025] to comparisons across multiple detector units. The method was previously introduced as a tamper detection method for authenticating a single radiation detector in nuclear safeguards and treaty verification scenarios, and works by randomly sampling detector configuration parameters to produce a sequence of spectra that form a baseline signature of an untampered system. At a later date, after potential tampering, the same random sequence of parameters is used to generate another series of spectra that can be compared against the baseline. Anomalies in the series of comparisons indicate changes in detector behavior, which may be due to tampering. One limitation of this original method is that once the detector has `gone downrange' and may have been tampered with, the original baseline is fixed, and a new trusted baseline can never be established if tests at new parameters are required. In this work, we extend our anti-tamper fuzz testing concept to multiple detector units, such that the downrange detector can be compared against a trusted or `golden copy' detector, even despite normal inter-detector manufacturing variations. We show using three NaI detectors that this inter-detector differential fuzz testing can detect a representative attack, even when the tested and golden copy detectors are from different manufacturers and have different performances. Here, detecting tampering requires visualizing the comparison metric vs. the parameter values and not just the sample number; moreover this baseline is non-linear and may require anomaly detection methods more complex than a simple threshold. Overall, this extension to multiple detectors improves prospects for operationalizing the technique in real-world treaty verification and safeguards contexts.

Explore related subjects

Keep this discovery

BibTeXRIS

Pei Yao Li, Jayson R. Vavrek, Sean Peisert. 2026-01-30. Inter-detector differential fuzz testing for tamper detection in gamma spectrometers. https://arxiv.org/abs/2602.00336

Cite the original work for its findings. Save a collection to share your selection of sources.

KEEP EXPLORING

Related papers

High-Speed Semi-FE Readout Module for ATLAS MDT at HL-LHC: Design and Production-Level Characterization

The High-Luminosity upgrade of the Large Hadron Collider (HL-LHC) introduces increased demands on the ATLAS Muon Spectrometer, particularly in terms of data throughput, timing distribution and system reliability. The Phase-II Chamber Service Module (CSM) is a key component of the upgraded Monitored Drift Tube (MDT) trigger and readout system, providing a high-speed interface between the front-end electronics and the backend systems. This paper describes the design and implementation of the Phase-II CSM, together with its validation. The results show that the CSM supports two independent optical uplinks, each operating at a line rate of 10.24 Gbps, together with clock distribution and slow control in the expected operating environment. Integration with small-diameter MDT (sMDT) chambers and tests with the prototype L0MDT trigger system are also presented. The CSM boards are now in production and will be used for installation and integration during the upcoming LHC Long Shutdown.

physics.ins-det

Spectral Discrimination of Deposited Gamma-Ray Energies in a Simulated CeBr$_3$ Scintillator

We show that wavelength measurements of individual detected optical photons may provide additional information about gamma-ray energy deposited in a CeBr$_3$ crystal when the detected-photon-count distributions overlap for nearby gamma-ray energies. Monoenergetic 662 and 629 keV gammas are used in a Geant4 simulation of a $25\times25\times20~\mathrm{mm^3}$ CeBr$_3$ crystal. Assuming a light yield of $6.0\times10^4$ photons/MeV, a wavelength-independent photon-detection efficiency of 30%, and a wavelength resolution of $\sigma_{\lambda}=40$ nm, we find that the fraction of photons reconstructed above 385 nm gives an event-level separation of $\sim$ 2 standard deviations between the 662 and 629 keV event populations selected within the same $\sim$ 1%-wide detected-photon-count interval. No timing or reconstructed interaction-position information is used. The result demonstrates, within the present simulation model, that event-dependent optical spectra can retain energy information beyond an undifferentiated photon count.

physics.ins-det

Operation of a negative ion gas time projection chamber without electronegative fill gases

The high fidelity reconstruction of particle tracks in micropatterned gaseous time projection chambers renders this technology ideal for future rare-event searches, including direction-sensitive dark matter experiments. Large drift distances are typically required for such experiments, so that the overall spatial resolution is limited by diffusion. Negative ion drift exhibits lower diffusion than electron drift and is thus an attractive option for realising a large-scale detector. The use of electronegative gases to create negative ions introduces technical challenges, most notably a reduction in gain when compared to conventional gas mixtures. In this study, we demonstrate a new method for negative ion generation via dissociative electron attachment using the conventional molecular fill gas CF$_4$. Our optical measurements of negative ion drift indicate electron attachment lengths of $<$1 mm and comparable gain to electron avalanches. The individual negative ion avalanches were also time-resolved, allowing the number of ions reaching the readout to be counted. We measure an improved energy resolution by single ion counting, relative to an integrated electron avalanche signal measured under identical gain conditions.

physics.ins-det