SearcharxivSearch

arXiv · 2602.12658

High Negative Ion Gain MMThGEM-Micromegas Detector for Directional Dark Matter Searches

Abstract

Low pressure gaseous Negative Ion Time Projection Chambers (NITPCs) have been used previously by the DRIFT experiment to search for a directional Dark Matter (DM) signature. The main challenge with using a Negative Ion Drift (NID) gas target is the significantly lower gas gains to which they are typically limited. Recently, a MMThGEM device has been successfully demonstrated as an excellent gain stage device in the NID gas SF$_6$; capable of producing gas gains comparable with the electron drift gas CF$_4$. The next major challenge is to extend this high gain capability to multi-dimensional readout for the purpose of particle track reconstruction. The MMThGEM is therefore ideal for coupling to a strip readout detector like a Micromegas to achieve a high gain multi-dimensional Negative Ion (NI) readout plane, which is potentially suitable for the scale up required by future searches proposed by the CYGNUS consortium. In this paper, the first high gain demonstration of such a MMThGEM-Micromegas detector in low pressure SF$_6$ is described. This includes detector characterisation in a small test vessel resulting in the largest NI gas gain ever reported, 1.22 $\pm$ 0.08 $\times$ 10$^5$ , and directionality with alpha particles. Finally, this gain characterisation and tracking capability is leveraged to measure the energy and range of events, and identify those consistent with Nuclear Recoils (NRs), in a large cubic metre scale volume of SF$_6$ for the first time.

Explore related subjects

Keep this discovery

BibTeXRIS

A. G. McLean, S. Higashino, R. R. Marcelo Gregorio, K. Miuchi, N. J. C. Spooner. 2026-02-13. High Negative Ion Gain MMThGEM-Micromegas Detector for Directional Dark Matter Searches. https://arxiv.org/abs/2602.12658

Cite the original work for its findings. Save a collection to share your selection of sources.

KEEP EXPLORING

Related papers

High-Speed Semi-FE Readout Module for ATLAS MDT at HL-LHC: Design and Production-Level Characterization

The High-Luminosity upgrade of the Large Hadron Collider (HL-LHC) introduces increased demands on the ATLAS Muon Spectrometer, particularly in terms of data throughput, timing distribution and system reliability. The Phase-II Chamber Service Module (CSM) is a key component of the upgraded Monitored Drift Tube (MDT) trigger and readout system, providing a high-speed interface between the front-end electronics and the backend systems. This paper describes the design and implementation of the Phase-II CSM, together with its validation. The results show that the CSM supports two independent optical uplinks, each operating at a line rate of 10.24 Gbps, together with clock distribution and slow control in the expected operating environment. Integration with small-diameter MDT (sMDT) chambers and tests with the prototype L0MDT trigger system are also presented. The CSM boards are now in production and will be used for installation and integration during the upcoming LHC Long Shutdown.

physics.ins-det

Spectral Discrimination of Deposited Gamma-Ray Energies in a Simulated CeBr$_3$ Scintillator

We show that wavelength measurements of individual detected optical photons may provide additional information about gamma-ray energy deposited in a CeBr$_3$ crystal when the detected-photon-count distributions overlap for nearby gamma-ray energies. Monoenergetic 662 and 629 keV gammas are used in a Geant4 simulation of a $25\times25\times20~\mathrm{mm^3}$ CeBr$_3$ crystal. Assuming a light yield of $6.0\times10^4$ photons/MeV, a wavelength-independent photon-detection efficiency of 30%, and a wavelength resolution of $\sigma_{\lambda}=40$ nm, we find that the fraction of photons reconstructed above 385 nm gives an event-level separation of $\sim$ 2 standard deviations between the 662 and 629 keV event populations selected within the same $\sim$ 1%-wide detected-photon-count interval. No timing or reconstructed interaction-position information is used. The result demonstrates, within the present simulation model, that event-dependent optical spectra can retain energy information beyond an undifferentiated photon count.

physics.ins-det

Operation of a negative ion gas time projection chamber without electronegative fill gases

The high fidelity reconstruction of particle tracks in micropatterned gaseous time projection chambers renders this technology ideal for future rare-event searches, including direction-sensitive dark matter experiments. Large drift distances are typically required for such experiments, so that the overall spatial resolution is limited by diffusion. Negative ion drift exhibits lower diffusion than electron drift and is thus an attractive option for realising a large-scale detector. The use of electronegative gases to create negative ions introduces technical challenges, most notably a reduction in gain when compared to conventional gas mixtures. In this study, we demonstrate a new method for negative ion generation via dissociative electron attachment using the conventional molecular fill gas CF$_4$. Our optical measurements of negative ion drift indicate electron attachment lengths of $<$1 mm and comparable gain to electron avalanches. The individual negative ion avalanches were also time-resolved, allowing the number of ions reaching the readout to be counted. We measure an improved energy resolution by single ion counting, relative to an integrated electron avalanche signal measured under identical gain conditions.

physics.ins-det