SearcharxivSearch

arXiv · 2603.04942

Fast array-based particle coincidence detection in a TimePix3-based velocity map imaging instrument

Abstract

With the development of high repetition rate laser sources and advanced multi-particle correlation analyses such as covariance mapping, particle detection techniques such as velocity map imaging (VMI) are poised to offer unprecedented views into molecular phenomena. Taking full advantage of the high count rates in these experiments requires the development of detectors with sufficient spatial and temporal resolution that can process data in real time. The TimePix3 camera (TPX3CAM) is an event-based pixel detector capable of spatio-temporally localizing many simultaneous particle hits in an efficient manner. While the sparse nature of the data stream allows for compact representation of particle hits, it also presents algorithmic and computational challenges for clustering individual pixels into hits. Here we present the theory and application of a rapid data processing and centroiding algorithm for ion and electron hits collected in a VMI instrument. The array-based computations that comprise the algorithm take full advantage of the data sparsity of the TimePix3 data stream and localize particle hits on the microchannel plate (MCP) to better than a single pixel on the pixel detector. Centroiding can be parallelized on a commercially available graphics processing unit (GPU) for additional speed. Using these innovations, data processing occurs about 25 times faster than data acquisition, for a 1 kHz repetition rate instrument and tens of particles per shot. In addition to its speed, the TPX3CAM detector outperforms state-of-the-art delay line anode detectors at discriminating multiple simultaneous hits, enabling high-fidelity coincidence and covariance studies in the near future.

Explore related subjects

Keep this discovery

BibTeXRIS

Ian Gabalski, Eleanor Weckwerth, Chuan Cheng, Philip H. Bucksbaum. 2026-03-05. Fast array-based particle coincidence detection in a TimePix3-based velocity map imaging instrument. https://arxiv.org/abs/2603.04942

Cite the original work for its findings. Save a collection to share your selection of sources.

KEEP EXPLORING

Related papers

High-Speed Semi-FE Readout Module for ATLAS MDT at HL-LHC: Design and Production-Level Characterization

The High-Luminosity upgrade of the Large Hadron Collider (HL-LHC) introduces increased demands on the ATLAS Muon Spectrometer, particularly in terms of data throughput, timing distribution and system reliability. The Phase-II Chamber Service Module (CSM) is a key component of the upgraded Monitored Drift Tube (MDT) trigger and readout system, providing a high-speed interface between the front-end electronics and the backend systems. This paper describes the design and implementation of the Phase-II CSM, together with its validation. The results show that the CSM supports two independent optical uplinks, each operating at a line rate of 10.24 Gbps, together with clock distribution and slow control in the expected operating environment. Integration with small-diameter MDT (sMDT) chambers and tests with the prototype L0MDT trigger system are also presented. The CSM boards are now in production and will be used for installation and integration during the upcoming LHC Long Shutdown.

physics.ins-det

Spectral Discrimination of Deposited Gamma-Ray Energies in a Simulated CeBr$_3$ Scintillator

We show that wavelength measurements of individual detected optical photons may provide additional information about gamma-ray energy deposited in a CeBr$_3$ crystal when the detected-photon-count distributions overlap for nearby gamma-ray energies. Monoenergetic 662 and 629 keV gammas are used in a Geant4 simulation of a $25\times25\times20~\mathrm{mm^3}$ CeBr$_3$ crystal. Assuming a light yield of $6.0\times10^4$ photons/MeV, a wavelength-independent photon-detection efficiency of 30%, and a wavelength resolution of $\sigma_{\lambda}=40$ nm, we find that the fraction of photons reconstructed above 385 nm gives an event-level separation of $\sim$ 2 standard deviations between the 662 and 629 keV event populations selected within the same $\sim$ 1%-wide detected-photon-count interval. No timing or reconstructed interaction-position information is used. The result demonstrates, within the present simulation model, that event-dependent optical spectra can retain energy information beyond an undifferentiated photon count.

physics.ins-det

Operation of a negative ion gas time projection chamber without electronegative fill gases

The high fidelity reconstruction of particle tracks in micropatterned gaseous time projection chambers renders this technology ideal for future rare-event searches, including direction-sensitive dark matter experiments. Large drift distances are typically required for such experiments, so that the overall spatial resolution is limited by diffusion. Negative ion drift exhibits lower diffusion than electron drift and is thus an attractive option for realising a large-scale detector. The use of electronegative gases to create negative ions introduces technical challenges, most notably a reduction in gain when compared to conventional gas mixtures. In this study, we demonstrate a new method for negative ion generation via dissociative electron attachment using the conventional molecular fill gas CF$_4$. Our optical measurements of negative ion drift indicate electron attachment lengths of $<$1 mm and comparable gain to electron avalanches. The individual negative ion avalanches were also time-resolved, allowing the number of ions reaching the readout to be counted. We measure an improved energy resolution by single ion counting, relative to an integrated electron avalanche signal measured under identical gain conditions.

physics.ins-det