SearcharxivSearch

arXiv · 2605.12891

Dynamic Modulated Arc Therapy (DMAT): A Time Aware, Modulation Steered Optimization Framework for Next Generation Radiotherapy Delivery

Abstract

Background: Conventional VMAT optimization treats delivery time and deliverability as emergent properties of control-point-centric models that ignore finite acceleration and other dynamic limits. As linacs gain axis speed and dose rate, the plan quality-time trade-off must become explicit and steerable. Purpose: To introduce Dynamic Modulated Arc Therapy (DMAT), a time-aware, modulation-steered framework that jointly optimizes dosimetric quality, delivery time, and modulation complexity. Methods: DMAT couples direct machine emulation (axis synchronization, finite acceleration), dynamic modulation control, and clinical metrics used directly as cost functions. A user-selected modulation level (-3 to +3) governs leaf-travel allowance, total MU, aperture complexity, and control-point (CP) density. Plans are generated by progressive-resolution optimization alternating dosimetric with sequencing/deliverability updates, with non-uniform CP redistribution and complexity-reducing post-processing. DMAT was evaluated on head-and-neck, lung SBRT, and prostate SBRT cases using a hypothetical accelerated system (2.5 RPM gantry, 6.25 cm/s MLC, 3000 MU/min). Results: Increasing modulation level raised modulation surrogates (MU/Gy, aperture complexity) and delivery time, with additional CPs concentrated in arc sectors where finer angular resolution was most beneficial. The trade-off was site dependent: head-and-neck gained substantial plan quality, whereas prostate and lung SBRT gained little beyond baseline. Negative levels predictably shortened delivery time at a fixed CP budget, with quantifiable quality loss. Conclusions: DMAT co-optimizes plan quality and modulation complexity under machine-aware timing and explicit user control, making quality-time trade-offs transparent and navigable and supporting time-constrained workflows such as motion management and adaptive radiotherapy.

Explore related subjects

Keep this discovery

BibTeXRIS

Taoran Li, Esa Kuusela, Emmi Ruokokoski, Heini Hyvönen, Jerry Jaboin, Mirko Myllykoski, Jussi Nurminen, Riku Paananen, Jarkko Peltola, Marko Rusanen, Martin Sabel, Kevin Moore, Christopher Boylan. 2026-05-13. Dynamic Modulated Arc Therapy (DMAT): A Time Aware, Modulation Steered Optimization Framework for Next Generation Radiotherapy Delivery. https://doi.org/10.1002/acm2.70764

Cite the original work for its findings. Save a collection to share your selection of sources.

KEEP EXPLORING

Related papers

Phase-contrast micro-CT for intra-operative breast tumour margin assessment using a microfocus x-ray source and photon-counting detector

Objective: Intra-operative tumour margin assessment during breast-conserving surgery requires rapid, high-resolution imaging of excised tissue, allowing the surgical team to take appropriate action within a single operation. This study evaluates a custom propagation-based phase-contrast micro-computed tomography (micro-CT) system designed to meet these clinical constraints without specialised optical elements. Methods: The experimental setup pairs a microfocus x-ray source with a photon-counting detector in a cone-beam geometry. We explore how the spatial coherence of the source can provide propagation-based phase contrast -- with no additional specialised optical elements -- and balance this against maximising the x-ray flux of the cone-beam geometry. System performance was evaluated across two anode target materials and filtration configurations at various tube power settings. Imaging capabilities were validated using anthropomorphic breast tissue phantoms and a formalin-fixed paraffin-embedded (FFPE) breast tissue specimen, with reconstructions compared against gold-standard histology. Results: An unfiltered tungsten target operated at 40 kVp yielded optimal image quality. The optimised system achieved high-resolution CT reconstructions of a 5 cm diameter sample with an isotropic voxel size of 40.7 $\upmu\text{m}$ in a scan time of 12 minutes. Reconstructed volumes demonstrated strong visual correlation with corresponding histology slides. Conclusion: Combining a microfocus source with a photon-counting detector enables high-resolution, phase-contrast micro-CT within a clinically viable timeframe, demonstrating strong potential for intra-operative margin assessment.

physics.med-ph

Understanding Search and Decision Errors in Liver Metastasis Detection and the Effects of Lower Radiation Dose

The detection performance of liver metastases decreases with the reduction of radiation dose, but misses are heterogeneous. Previous eye tracking work has characterized missed metastases into two categories: search errors i.e., the eyes never land on the lesion, and decision errors i.e., the lesion is seen but not recognized as malignant. We integrated three prior reader studies to answer this question. In all studies, radiologists interpreted the same set of 40 contrast enhanced abdominal CT exams containing 91 liver metastases whose locations had been previously marked. In two studies, the workstation recorded their gaze and eye movements. Using eye dwell times, metastases were classified as search-error-dominant (majority of misses had <2 sec gaze time) or decision-error-dominant (>2 sec gaze time). In the third study, exams were interpreted both at 120 and 200 quality reference mAs (QRM) by ten radiologists. The third study did not include eye tracking. Out of 91 liver metastases, we excluded 16 that were never missed in the eye tracking studies and used 75 liver metastases for the present study.

physics.med-ph

Develop and Optimize 5DCT Imaging Simulation and Reconstruction Methods

Purpose: To develop and optimize a 5DCT (3D + cardiac phase + respiratory phase) imaging simulation and reconstruction pipeline, and to compare two sinogram-space interpolation methods for reconstructing images at arbitrary combinations of cardiac and respiratory phase. Methods: Helical CT projections were simulated from the 4D XCAT phantom across a range of cardiac and respiratory motion states, with Poisson and electronic noise added. Ground-truth-matched volumes were generated at 5 cardiac phases and 10 respiratory amplitudes (50 total phase combinations). Because acquired projections are sparsely and unevenly distributed across this joint phase space, each target slice was reconstructed by interpolating rebinned sinogram rows to the target cardiac phase and respiratory amplitude, using either 2D scattered barycentric interpolation or 2D scattered local linear interpolation with a circular kernel for cardiac phase. Reconstructed volumes were compared to phantom ground truth using mean absolute error (MAE), and to conventional respiratory-gated 4DCT (r4DCT) reconstructed from the same simulated data. Results: Both interpolation methods eliminated the severe axial misalignment artifacts present when helical projections were reconstructed without phase-space interpolation. Local linear interpolation achieved lower MAE than barycentric interpolation across most tested conditions, with the largest improvement at low pitch. The 5DCT pipeline also produced respiratory-only volumes with fewer residual cardiac-motion artifacts than conventional r4DCT reconstructed from the same projection data, including at standard clinical pitch (0.1). Conclusions: 5DCT reconstruction using sinogram-space interpolation is feasible and can jointly resolve cardiac and respiratory motion with better accuracy than conventional 4DCT reconstruction.

physics.med-ph