SearcharxivSearch

arXiv · 2605.19547

On the Hyperelastic Behavior of the Boar Diaphragmatic Tendon Membrane by Inflation Tests and Modeling

Abstract

Background: Despite the large variety of materials used to repair congenital diaphragmatic hernia (CDH), none has proven ideal due to complications and risk of recurrence. Understanding the mechanical behavior of the diaphragm's central tendon is essential for developing biomimetic prostheses. Objective: This study aims to characterize the hyperelastic behavior of the porcine diaphragmatic tendon under biaxial loading conditions. Methods: Biaxial hyperelastic response of the porcine diaphragmatic central tendon was characterized using bulge inflation tests combined with full-field stereo digital image correlation (3D-DIC). Principal stretches were extracted from the reconstructed three-dimensional geometry using a spherical-cap approximation, with corrections for clamping-induced pre-deformation. Several incompressible isotropic hyperelastic models (Neo-Hookean, Mooney-Rivlin, Yeoh and Fung) were first evaluated as phenomenological baselines. To account for the anisotropic mechanical signature of the tendon, a transversely isotropic hyperelastic formulation of the Humphrey-Yin type was implemented. This model represents an effective anisotropic response associated with the lamellar and collagen-rich structure of the tissue through its thickness, while assuming isotropy within the membrane plane. Results: The diaphragm tissue exhibited an exponential mechanical response. Neo-Hookean and Mooney-Rivlin models failed to capture the observed behavior, while the Yeoh model slightly overestimated nonlinearity. The Fung model provided the closest fit to the nonlinear pressure-stretch response, yet failed to reproduce the directional differences observed between meridional and circumferential stretches. The Humphrey-Yin model provided a markedly improved description of the experimental data over the full inflation range. Parameter identification revealed that the transversely isotropic contribution dominated the strain-energy response, highlighting the limitations of isotropic constitutive laws for modeling diaphragmatic tendon mechanics, even under macroscopically axisymmetric inflation. Despite specimen-to-specimen variability, no significant differences were observed between left and right diaphragm samples. Conclusion: Overall, this work demonstrates that effective anisotropic hyperelastic formulations are required to describe the biaxial mechanical behavior of the diaphragmatic central tendon under inflation loading. The proposed experimental-numerical framework provides a robust basis for biomechanical modeling and constitutes a first step toward the development of biomimetic prosthetic materials for diaphragmatic repair.

Explore related subjects

Keep this discovery

BibTeXRIS

R. Anwar, J. Vasquez-Villegas, S. Le Floc'h, P. Royer, N. Bahlouli, Christiane Wagner-Kocher. 2026-05-19. On the Hyperelastic Behavior of the Boar Diaphragmatic Tendon Membrane by Inflation Tests and Modeling. https://arxiv.org/abs/2605.19547

Cite the original work for its findings. Save a collection to share your selection of sources.

KEEP EXPLORING

Related papers

Phase-contrast micro-CT for intra-operative breast tumour margin assessment using a microfocus x-ray source and photon-counting detector

Objective: Intra-operative tumour margin assessment during breast-conserving surgery requires rapid, high-resolution imaging of excised tissue, allowing the surgical team to take appropriate action within a single operation. This study evaluates a custom propagation-based phase-contrast micro-computed tomography (micro-CT) system designed to meet these clinical constraints without specialised optical elements. Methods: The experimental setup pairs a microfocus x-ray source with a photon-counting detector in a cone-beam geometry. We explore how the spatial coherence of the source can provide propagation-based phase contrast -- with no additional specialised optical elements -- and balance this against maximising the x-ray flux of the cone-beam geometry. System performance was evaluated across two anode target materials and filtration configurations at various tube power settings. Imaging capabilities were validated using anthropomorphic breast tissue phantoms and a formalin-fixed paraffin-embedded (FFPE) breast tissue specimen, with reconstructions compared against gold-standard histology. Results: An unfiltered tungsten target operated at 40 kVp yielded optimal image quality. The optimised system achieved high-resolution CT reconstructions of a 5 cm diameter sample with an isotropic voxel size of 40.7 $\upmu\text{m}$ in a scan time of 12 minutes. Reconstructed volumes demonstrated strong visual correlation with corresponding histology slides. Conclusion: Combining a microfocus source with a photon-counting detector enables high-resolution, phase-contrast micro-CT within a clinically viable timeframe, demonstrating strong potential for intra-operative margin assessment.

physics.med-ph

Understanding Search and Decision Errors in Liver Metastasis Detection and the Effects of Lower Radiation Dose

The detection performance of liver metastases decreases with the reduction of radiation dose, but misses are heterogeneous. Previous eye tracking work has characterized missed metastases into two categories: search errors i.e., the eyes never land on the lesion, and decision errors i.e., the lesion is seen but not recognized as malignant. We integrated three prior reader studies to answer this question. In all studies, radiologists interpreted the same set of 40 contrast enhanced abdominal CT exams containing 91 liver metastases whose locations had been previously marked. In two studies, the workstation recorded their gaze and eye movements. Using eye dwell times, metastases were classified as search-error-dominant (majority of misses had <2 sec gaze time) or decision-error-dominant (>2 sec gaze time). In the third study, exams were interpreted both at 120 and 200 quality reference mAs (QRM) by ten radiologists. The third study did not include eye tracking. Out of 91 liver metastases, we excluded 16 that were never missed in the eye tracking studies and used 75 liver metastases for the present study.

physics.med-ph

Develop and Optimize 5DCT Imaging Simulation and Reconstruction Methods

Purpose: To develop and optimize a 5DCT (3D + cardiac phase + respiratory phase) imaging simulation and reconstruction pipeline, and to compare two sinogram-space interpolation methods for reconstructing images at arbitrary combinations of cardiac and respiratory phase. Methods: Helical CT projections were simulated from the 4D XCAT phantom across a range of cardiac and respiratory motion states, with Poisson and electronic noise added. Ground-truth-matched volumes were generated at 5 cardiac phases and 10 respiratory amplitudes (50 total phase combinations). Because acquired projections are sparsely and unevenly distributed across this joint phase space, each target slice was reconstructed by interpolating rebinned sinogram rows to the target cardiac phase and respiratory amplitude, using either 2D scattered barycentric interpolation or 2D scattered local linear interpolation with a circular kernel for cardiac phase. Reconstructed volumes were compared to phantom ground truth using mean absolute error (MAE), and to conventional respiratory-gated 4DCT (r4DCT) reconstructed from the same simulated data. Results: Both interpolation methods eliminated the severe axial misalignment artifacts present when helical projections were reconstructed without phase-space interpolation. Local linear interpolation achieved lower MAE than barycentric interpolation across most tested conditions, with the largest improvement at low pitch. The 5DCT pipeline also produced respiratory-only volumes with fewer residual cardiac-motion artifacts than conventional r4DCT reconstructed from the same projection data, including at standard clinical pitch (0.1). Conclusions: 5DCT reconstruction using sinogram-space interpolation is feasible and can jointly resolve cardiac and respiratory motion with better accuracy than conventional 4DCT reconstruction.

physics.med-ph