SearcharxivSearch

arXiv · 2605.20870

Development of a xenon triple point apparatus suitable for calibrating long-stem SPRTs and preliminary measurements of the temperature

Abstract

Xenon is of high chemical-physical stability and health compatibility. The xenon triple point (Xe TP) is accounted for a promising candidate replacing the mercury triple point (Hg TP) from the set of the defining fixed points of the international temperature scale ITS-90. The success of the alternative highly depends on the level of the realization of the Xe TP using long-stem standard platinum resistance thermometers (LSPRTs). We report in this article our study on the development of an immersion-type Xe TP apparatus, which is suitable for calibration of both LSPRTs and capsule standard platinum resistance thermometers (CSPRT). We realize the melting plateaus of the Xe TP using the continuous heating method on the apparatus. The effective melting plateaus extend for 8-12 hours long with temperature flatness range of 0.37 mK-1.0 mK over the melted fractions from 0.2 to 0.75. We find the axial heat leak contributing a principal effect influencing measurements of the Xe TP. We investigate the effect by varying the offset temperatures on the outer wall of the Xe TP cell. We measure the Xe TP using two LSPRTs upon correction of the axial heat leak. The new measurement, giving the Xe TP of 161.405 71 (55) K (k=1) at the melted fraction F=1.0, agrees well with those previously obtained by the adiabatic apparatuses. Their differences fall within 0.11 mK to 0.42 mK. by. Those differences are well covered by the estimated measurement uncertainty.

Explore related subjects

Keep this discovery

BibTeXRIS

Yikun Zhao, Jintao Zhang, Xiaojuan Feng, Yu Liang, Yongdong He, Hua Zhuo, Xiangrui Deng, Haibing Li. 2026-05-20. Development of a xenon triple point apparatus suitable for calibrating long-stem SPRTs and preliminary measurements of the temperature. https://arxiv.org/abs/2605.20870

Cite the original work for its findings. Save a collection to share your selection of sources.

KEEP EXPLORING

Related papers

High-Speed Semi-FE Readout Module for ATLAS MDT at HL-LHC: Design and Production-Level Characterization

The High-Luminosity upgrade of the Large Hadron Collider (HL-LHC) introduces increased demands on the ATLAS Muon Spectrometer, particularly in terms of data throughput, timing distribution and system reliability. The Phase-II Chamber Service Module (CSM) is a key component of the upgraded Monitored Drift Tube (MDT) trigger and readout system, providing a high-speed interface between the front-end electronics and the backend systems. This paper describes the design and implementation of the Phase-II CSM, together with its validation. The results show that the CSM supports two independent optical uplinks, each operating at a line rate of 10.24 Gbps, together with clock distribution and slow control in the expected operating environment. Integration with small-diameter MDT (sMDT) chambers and tests with the prototype L0MDT trigger system are also presented. The CSM boards are now in production and will be used for installation and integration during the upcoming LHC Long Shutdown.

physics.ins-det

Spectral Discrimination of Deposited Gamma-Ray Energies in a Simulated CeBr$_3$ Scintillator

We show that wavelength measurements of individual detected optical photons may provide additional information about gamma-ray energy deposited in a CeBr$_3$ crystal when the detected-photon-count distributions overlap for nearby gamma-ray energies. Monoenergetic 662 and 629 keV gammas are used in a Geant4 simulation of a $25\times25\times20~\mathrm{mm^3}$ CeBr$_3$ crystal. Assuming a light yield of $6.0\times10^4$ photons/MeV, a wavelength-independent photon-detection efficiency of 30%, and a wavelength resolution of $\sigma_{\lambda}=40$ nm, we find that the fraction of photons reconstructed above 385 nm gives an event-level separation of $\sim$ 2 standard deviations between the 662 and 629 keV event populations selected within the same $\sim$ 1%-wide detected-photon-count interval. No timing or reconstructed interaction-position information is used. The result demonstrates, within the present simulation model, that event-dependent optical spectra can retain energy information beyond an undifferentiated photon count.

physics.ins-det

Operation of a negative ion gas time projection chamber without electronegative fill gases

The high fidelity reconstruction of particle tracks in micropatterned gaseous time projection chambers renders this technology ideal for future rare-event searches, including direction-sensitive dark matter experiments. Large drift distances are typically required for such experiments, so that the overall spatial resolution is limited by diffusion. Negative ion drift exhibits lower diffusion than electron drift and is thus an attractive option for realising a large-scale detector. The use of electronegative gases to create negative ions introduces technical challenges, most notably a reduction in gain when compared to conventional gas mixtures. In this study, we demonstrate a new method for negative ion generation via dissociative electron attachment using the conventional molecular fill gas CF$_4$. Our optical measurements of negative ion drift indicate electron attachment lengths of $<$1 mm and comparable gain to electron avalanches. The individual negative ion avalanches were also time-resolved, allowing the number of ions reaching the readout to be counted. We measure an improved energy resolution by single ion counting, relative to an integrated electron avalanche signal measured under identical gain conditions.

physics.ins-det