arXiv · 2607.00822
Axion Polarimetric Experiment (APE)
Abstract
We present the Axion Polarimetric Experiment (APE), a cavity-enhanced polarimeter designed to search for ultralight axion and axion-like-particle dark matter through a time-dependent rotation of the linear polarization of laser light. In cavity-based schemes, intracavity quarter-wave plates can restore coherent buildup of the axion-induced orthogonal polarization, but their transmissive loss limits the achievable finesse. To avoid transmissive intracavity optics, we propose a folded Fabry-Perot cavity that employs dielectric phase-shifting mirrors. At an incidence angle near $45^\circ$, these mirrors provide a reflection-phase difference $\Delta\phi \equiv \phi_s-\phi_p \simeq \pi/2$ between $s$ and $p$ polarizations and therefore act as reflective quarter-wave plates. We present the coating design, thickness optimization, and measurements of the phase shift and optical loss of the phase-shifting mirrors. Using a heterodyne polarimetric readout and an explicitly stated noise model, we derive design-level sensitivity projections for the axion-photon coupling $g_{a\gamma\gamma}$. These projections should be interpreted as target sensitivities for the proposed cavity configuration, since the full-system birefringence noise and angular-jitter coupling remain to be measured.
Explore related subjects
Keep this discovery
Qazal Rokn, Ryan Netrval, Aldo Ejlli, Guido Mueller. 2026-07-01. Axion Polarimetric Experiment (APE). https://arxiv.org/abs/2607.00822
Cite the original work for its findings. Save a collection to share your selection of sources.