SearcharxivSearch

arXiv · 2607.04271

Neural-Network-Assisted Binary Template Construction for Matrix-Based Pattern Matching in the STCF MDC

Abstract

The Super Tau-Charm Facility, operating at high luminosity, will produce high event rates and high data throughput, imposing stringent requirements on fast track finding and data reduction and compression algorithms in the High-Level Trigger. Local track segment finding in the Main Drift Chamber underpins subsequent segment combination and full track reconstruction, yet high background rates and limited detection efficiency can significantly increase the risk of false triggers and signal loss in pattern matching algorithms. This paper presents a neural-network-assisted framework for constructing binary template libraries used in matrix-based pattern matching for MDC local track segment finding. The framework formulates template construction as a differentiable multi-objective optimization problem, employing a neural network to jointly learn template parameters under multiple constraints. After training, only binary template pairs are exported and deployed into the existing bitwise pattern matching routine, requiring no neural network inference at runtime and thus preserving the deterministic, fast, and parallelizable nature of the online algorithm. Experimental results based on simulation samples demonstrate that, under limited detection efficiency, the resulting template library maintains relatively high signal retention across different transverse momentum ranges and background levels, and can be flexibly tailored to adjust the coverage range according to practical requirements. The proposed approach decouples the physics performance from the computational speed by combining the improved physics performance brought by offline neural-network-based optimization with the determinism and high speed of a conventional online algorithm, suggesting a new research direction for artificial-intelligence-enhanced online data processing in high-luminosity particle collider experiments.

Explore related subjects

Keep this discovery

BibTeXRIS

Zhaoli Guo, Qingyu Li, Baolin Zhang, Jiarui Zhao, Aonan Zhu, Liang Peng, Huilin Li. 2026-07-05. Neural-Network-Assisted Binary Template Construction for Matrix-Based Pattern Matching in the STCF MDC. https://arxiv.org/abs/2607.04271

Cite the original work for its findings. Save a collection to share your selection of sources.

KEEP EXPLORING

Related papers

Production of Light Nuclei and Hypernuclei in Heavy-Ion Collisions

We review recent STAR and ALICE measurements of light-nucleus and hypernucleus yields, femtoscopic correlations, and collective flow presented at SQM 2026. Statistical-hadronization calculations provide a useful baseline for integrated yields but do not simultaneously describe all measured light-nucleus ratios across collision energies and system sizes. For bound states with mass number $A<4$, current coalescence calculations provide a broadly consistent description of yields, femtoscopic correlations, and collective flow, although the quantitative hypertriton comparison depends on the assumed few-body wave function. The suppressed production of resonant $^{4}$Li relative to compact $^{4}$He indicates an effect of nuclear structure and late-stage dynamics. However, the quantitative model comparison also depends on the treatment of feed-down from unstable states. In high-multiplicity $p$+$p$ collisions, pion-deuteron femtoscopy further indicates that most observed (anti)deuterons are formed through nucleon fusion after strong decays of short-lived resonances. Taken together, these measurements show that production chronology and internal nuclear structure leave measurable imprints on the physics observables.

hep-ex

Search for the process $e^+e^-\to f_1(1285)$ at the SND detector

In the experiment with the SND detector at the VEPP-2000 $e^+e^-$ collider, a search is performed for the direct production of the $C$-even $f_1(1285)$ resonance in $e^+e^-$ collisions. The analysis is based on data with an integrated luminosity of about 200 pb$^{-1}$, accumulated in the center-of-mass energy range of 1.14--1.46 GeV, of which about 72 pb$^{-1}$ were recorded near the maximum of the $f_1(1285)$ resonance. The $f_1(1285)$ production cross section at the resonance maximum $\sigma(e^+e^-\to f_1)=(31\pm 13\pm 2)$ pb and the branching fraction $B(f_1(1285)\to e^+e^-)=(3.5\pm 1.4\pm 0.3)\times 10^{-9}$ have been measured. The significance of the observation of the $e^+e^-\to f_1(1285)$ process is $2.5\sigma$. Since the significance is low, we also present the upper limits at the 90% confidence level: $\sigma(e^+e^-\to f_1)<48\mbox{ pb}$ and $B(f_1(1285)\to e^+e^-)<5.4\times 10^{-9}$.

hep-ex

Projected Sensitivity to Slow Muonphilic Dark Matter with Accelerator Muon Beams

The nature of dark matter (DM) remains one of the most enduring open questions in modern physics, and muonphilic DM has emerged as a promising scenario that complements traditional DM candidates. Following the recently established cosmic-ray muon scattering approach, we investigate the sensitivity for probing slow muonphilic DM with accelerator muon beams. A Geant4-based simulation framework is developed, incorporating the detector geometry from the PKMu muon tomography system and a dedicated elastic $\mu$-DM scattering process. The projected sensitivity is found to be largely insensitive to both the beam energy and the transverse beam size when the beam is fully contained within the detector acceptance. For a benchmark beam intensity of $10^5/\rm{s}$, the simulated pure-muon beam surpasses the existing cosmic-ray limit of $1.61\times10^{-17}$ cm$^2$ at $m_{\rm DM}=1$ GeV within approximately 11 seconds. A realistic muon beam phase-space distribution based on simulations for the High Intensity heavy-ion Accelerator Facility (HIAF) is also implemented, yielding projected limits that improve upon the cosmic-ray results by nearly two orders of magnitude in a one-day exposure. These results demonstrate that a beam-muon scattering experiment offers a robust and promising route toward significantly improved sensitivity to slow muonphilic DM.

hep-ex