SearcharxivSearch

arXiv · 2608.23511

Post-diffusion cooling effects on Hall-derived active lithium donor profiles in high-purity germanium

Abstract

Lithium (Li) diffusion is commonly used to form $n^{+}$ contacts in high-purity germanium (HPGe) detectors, but the final electrically active donor profile can be sensitive to the post-diffusion thermal history. Li was introduced into HPGe coupons using a lithium-in-oil suspension and diffused for $30~\mathrm{min}$ at nominal temperatures of $240$--$310~^{\circ}\mathrm{C}$. Short- and long-cooling protocols were documented by measured witness-Ge cooling histories. Sequential material removal combined with Hall-effect measurements at $77~\mathrm{K}$ was used to reconstruct difference-derived apparent Hall donor profiles. Because Hall response in a nonuniform conducting layer is mobility weighted, these profiles are operational electrically active-donor metrics rather than direct local or total-Li concentration profiles. Complementary-error-function fits were used to obtain the extrapolated apparent intercept $N_{s,\mathrm{app}}$ and the apparent profile-width parameter $D_{\mathrm{app}}$. For the coupons studied, short cooling was associated with larger $N_{s,\mathrm{app}}$ and sharper profiles, whereas long cooling was associated with lower $N_{s,\mathrm{app}}$ and broader low-concentration tails. Fit-derived concentration-threshold depths likewise extended farther into the Ge bulk for the long-cooling coupons. These results show that the complete post-diffusion thermal history should be considered when parameterizing Hall-active Li-diffused $n^{+}$ contacts for HPGe detector fabrication.

Explore related subjects

Keep this discovery

Explore connections, maps & timelines

BibTeXRIS

Kunming Dong, Dongming Mei, Anupama Karki, Partrick Burns, Sanjay Bhattarai. 2026-08-24. Post-diffusion cooling effects on Hall-derived active lithium donor profiles in high-purity germanium. https://arxiv.org/abs/2608.23511

Cite the original work for its findings. Save a collection to share your selection of sources.

KEEP EXPLORING

Related papers

High-Speed Semi-FE Readout Module for ATLAS MDT at HL-LHC: Design and Production-Level Characterization

The High-Luminosity upgrade of the Large Hadron Collider (HL-LHC) introduces increased demands on the ATLAS Muon Spectrometer, particularly in terms of data throughput, timing distribution and system reliability. The Phase-II Chamber Service Module (CSM) is a key component of the upgraded Monitored Drift Tube (MDT) trigger and readout system, providing a high-speed interface between the front-end electronics and the backend systems. This paper describes the design and implementation of the Phase-II CSM, together with its validation. The results show that the CSM supports two independent optical uplinks, each operating at a line rate of 10.24 Gbps, together with clock distribution and slow control in the expected operating environment. Integration with small-diameter MDT (sMDT) chambers and tests with the prototype L0MDT trigger system are also presented. The CSM boards are now in production and will be used for installation and integration during the upcoming LHC Long Shutdown.

physics.ins-det

Spectral Discrimination of Deposited Gamma-Ray Energies in a Simulated CeBr$_3$ Scintillator

We show that wavelength measurements of individual detected optical photons may provide additional information about gamma-ray energy deposited in a CeBr$_3$ crystal when the detected-photon-count distributions overlap for nearby gamma-ray energies. Monoenergetic 662 and 629 keV gammas are used in a Geant4 simulation of a $25\times25\times20~\mathrm{mm^3}$ CeBr$_3$ crystal. Assuming a light yield of $6.0\times10^4$ photons/MeV, a wavelength-independent photon-detection efficiency of 30%, and a wavelength resolution of $\sigma_{\lambda}=40$ nm, we find that the fraction of photons reconstructed above 385 nm gives an event-level separation of $\sim$ 2 standard deviations between the 662 and 629 keV event populations selected within the same $\sim$ 1%-wide detected-photon-count interval. No timing or reconstructed interaction-position information is used. The result demonstrates, within the present simulation model, that event-dependent optical spectra can retain energy information beyond an undifferentiated photon count.

physics.ins-det

Operation of a negative ion gas time projection chamber without electronegative fill gases

The high fidelity reconstruction of particle tracks in micropatterned gaseous time projection chambers renders this technology ideal for future rare-event searches, including direction-sensitive dark matter experiments. Large drift distances are typically required for such experiments, so that the overall spatial resolution is limited by diffusion. Negative ion drift exhibits lower diffusion than electron drift and is thus an attractive option for realising a large-scale detector. The use of electronegative gases to create negative ions introduces technical challenges, most notably a reduction in gain when compared to conventional gas mixtures. In this study, we demonstrate a new method for negative ion generation via dissociative electron attachment using the conventional molecular fill gas CF$_4$. Our optical measurements of negative ion drift indicate electron attachment lengths of $<$1 mm and comparable gain to electron avalanches. The individual negative ion avalanches were also time-resolved, allowing the number of ions reaching the readout to be counted. We measure an improved energy resolution by single ion counting, relative to an integrated electron avalanche signal measured under identical gain conditions.

physics.ins-det