SearcharxivSearch

arXiv · 2609.01522

Fabrication and characterization of lithium-diffused inverted coaxial point-contact HPGe detectors

Abstract

High-purity germanium (HPGe) detectors with low capacitance, low electronic noise, and stable high-voltage operation are important for high-resolution gamma-ray spectroscopy and rare-event searches. We report the fabrication and characterization of two compact p-type inverted coaxial point-contact (ICPC) HPGe detectors, AK01 and AK02, produced from crystals grown at the University of South Dakota. Both devices use lithium-diffused $n^{+}$ outer contacts together with amorphous-Ge/Al point-contact electrodes. The principal advance is the implementation of this hybrid contact process on two independently fabricated USD-grown ICPC prototypes and the demonstration of stable electrical and spectroscopic operation. Both detectors exhibited picoampere-level leakage currents, operational depletion-voltage ranges of approximately 200--250~V (AK01) and 240--260~V (AK02), and estimated effective plateau capacitances of approximately 0.84 and 0.87~pF, respectively. Measurements with a $^{137}$Cs source yielded archived full-energy-peak FWHM values of 1.71 and 1.62~keV near 662~keV for AK01 and AK02, while AK02 yielded 1.04~keV FWHM at 59.5~keV with $^{241}$Am. Electric-field calculations reproduce the expected ICPC field configuration for the measured detector geometry. A Geant4 model of AK02 is used as a qualitative response study; its 0.8-mm Li-diffused inactive layer is an illustrative model assumption rather than a measured thickness, and its Gaussian broadening is constrained by the experimental resolution. The work therefore establishes the fabrication and operation of compact lithium-diffused ICPC prototypes while identifying quantitative inactive-layer characterization as an important next step.

Explore related subjects

Keep this discovery

BibTeXRIS

Anupama Karki, Kunming Dong, Dongming Mei. 2026-09-01. Fabrication and characterization of lithium-diffused inverted coaxial point-contact HPGe detectors. https://arxiv.org/abs/2609.01522

Cite the original work for its findings. Save a collection to share your selection of sources.

KEEP EXPLORING

Related papers

High-Speed Semi-FE Readout Module for ATLAS MDT at HL-LHC: Design and Production-Level Characterization

The High-Luminosity upgrade of the Large Hadron Collider (HL-LHC) introduces increased demands on the ATLAS Muon Spectrometer, particularly in terms of data throughput, timing distribution and system reliability. The Phase-II Chamber Service Module (CSM) is a key component of the upgraded Monitored Drift Tube (MDT) trigger and readout system, providing a high-speed interface between the front-end electronics and the backend systems. This paper describes the design and implementation of the Phase-II CSM, together with its validation. The results show that the CSM supports two independent optical uplinks, each operating at a line rate of 10.24 Gbps, together with clock distribution and slow control in the expected operating environment. Integration with small-diameter MDT (sMDT) chambers and tests with the prototype L0MDT trigger system are also presented. The CSM boards are now in production and will be used for installation and integration during the upcoming LHC Long Shutdown.

physics.ins-det

Spectral Discrimination of Deposited Gamma-Ray Energies in a Simulated CeBr$_3$ Scintillator

We show that wavelength measurements of individual detected optical photons may provide additional information about gamma-ray energy deposited in a CeBr$_3$ crystal when the detected-photon-count distributions overlap for nearby gamma-ray energies. Monoenergetic 662 and 629 keV gammas are used in a Geant4 simulation of a $25\times25\times20~\mathrm{mm^3}$ CeBr$_3$ crystal. Assuming a light yield of $6.0\times10^4$ photons/MeV, a wavelength-independent photon-detection efficiency of 30%, and a wavelength resolution of $\sigma_{\lambda}=40$ nm, we find that the fraction of photons reconstructed above 385 nm gives an event-level separation of $\sim$ 2 standard deviations between the 662 and 629 keV event populations selected within the same $\sim$ 1%-wide detected-photon-count interval. No timing or reconstructed interaction-position information is used. The result demonstrates, within the present simulation model, that event-dependent optical spectra can retain energy information beyond an undifferentiated photon count.

physics.ins-det

Operation of a negative ion gas time projection chamber without electronegative fill gases

The high fidelity reconstruction of particle tracks in micropatterned gaseous time projection chambers renders this technology ideal for future rare-event searches, including direction-sensitive dark matter experiments. Large drift distances are typically required for such experiments, so that the overall spatial resolution is limited by diffusion. Negative ion drift exhibits lower diffusion than electron drift and is thus an attractive option for realising a large-scale detector. The use of electronegative gases to create negative ions introduces technical challenges, most notably a reduction in gain when compared to conventional gas mixtures. In this study, we demonstrate a new method for negative ion generation via dissociative electron attachment using the conventional molecular fill gas CF$_4$. Our optical measurements of negative ion drift indicate electron attachment lengths of $<$1 mm and comparable gain to electron avalanches. The individual negative ion avalanches were also time-resolved, allowing the number of ions reaching the readout to be counted. We measure an improved energy resolution by single ion counting, relative to an integrated electron avalanche signal measured under identical gain conditions.

physics.ins-det