arXiv · 2611.12905
Development of a Long-Term Stable Three-Axis Single-Beam Vector Optically Pumped Magnetometer Using a Buffer-Gas-Free Rubidium Vapor Cell and Direct Absorption Frequency Locking for Unshielded Geomagnetic Monitoring
Abstract
Optically pumped magnetometers (OPMs) achieve ultra-high sensitivity, yet sustaining long-term stability in unshielded, dynamic geomagnetic environments remains challenging. Here, we present the design and unshielded validation of a three-axis vector OPM achieving sub-nanotesla accuracy using an off-the-shelf rubidium (Rb) ampoule and a vertical-cavity surface-emitting laser (VCSEL). Unlike conventional sensors, this system operates without high-pressure buffer gases, mitigating wall-collision relaxation via a single-beam geometry combined with active zero-field nulling and adiabatic 70 kHz AC heating. To suppress VCSEL thermal wavelength drift without sub-Doppler optics, active frequency stabilization based on direct absorption spectroscopy (DAS) was implemented across a wide capture range. Continuous evaluation in an unshielded laboratory in Okayama against synthetic geomagnetic records from the Kakioka and Kanoya observatories demonstrated exceptional horizontal tracking fidelity. Concurrently, the vertical transfer matrix resolved the regional geomagnetic coast effect, extracting Parkinson induction vectors reflecting regional conductivity contrast, with high robustness against DC electric railway interference. Spectral characterization showed an intrinsic white noise floor of 10-20 pT above 1 Hz, enhanced by digital oversampling beyond the 12-bit DAC quantization limit, while residual overlapped Allan deviation revealed a 0.1 nT bias instability at 100-200 s integration times. These results prove that a compact, low-cost OPM platform based on commercial components can suppress long-term drift and serve as a reliable instrument for geophysical surveys and unshielded magnetic sensing.
Explore related subjects
Keep this discovery
Explore connections, maps & timelines
Minaru Kawamura. 2026-10-15. Development of a Long-Term Stable Three-Axis Single-Beam Vector Optically Pumped Magnetometer Using a Buffer-Gas-Free Rubidium Vapor Cell and Direct Absorption Frequency Locking for Unshielded Geomagnetic Monitoring. https://searcharxiv.com/abs/2611.12905
Citations retain the original authors and DOI and include this site’s record URL. If this discovery service contributed to your research, you can also cite Searcharxiv by Indiciae: BibTeX · RIS.