Searcharxiv⌕ Search

arXiv · 2611.17342

Accessible 3D Printed Archimedes System for Accurate and Precise Density Measurements and Uncertainty Analysis

Abstract

Accurate and precise density measurements are important for characterizing solid materials and for evaluating physical properties that are strongly affected by porosity. While several methods are available for determining density, measurements of small or irregularly shaped samples can be limited by sample geometry, balance precision, liquid density, and other experimental sources of uncertainty. In this study, an accessible Archimedes density measurement system was developed using 3D printed components and an analytical balance for the measurement of solid and liquid densities. The measurement of solid densities requires knowing the exact density of the liquid. Therefore, copper, vanadium, and indium standards were used to measure the densities of ethanol (0.8116 +/- 0.0005 g/cm3), distilled water (0.9982 +/- 0.0013 g/cm3), and hexanes (0.6748 +/- 0.0016 g/cm3), all of them showing strong agreement with literature values. Uncertainty analysis indicates that the relative uncertainty in the measured solid density decreases with increasing sample mass and balance precision, while higher density liquids can further reduce the required sample mass. The uncertainty of the immersed mass measurement was found to have a greater influence on the calculated density than the uncertainty of the air mass measurement. An open-source Archimedes LS software was developed to analyse liquid and solid densities including the corresponding uncertainties. These findings demonstrate that an accessible 3D printed Archimedes system combined with an open-source software provides a practical approach for improving the consistency and comparability of density measurements between laboratories.

Explore related subjects

Keep this discovery

Explore connections, maps & timelines

BibTeXRIS

Emily Doucet, Jan-Hendrik Pöhls. 2026-09-29. Accessible 3D Printed Archimedes System for Accurate and Precise Density Measurements and Uncertainty Analysis. https://searcharxiv.com/abs/2611.17342

Citations retain the original authors and DOI and include this site’s record URL. If this discovery service contributed to your research, you can also cite Searcharxiv by Indiciae: BibTeX · RIS.

KEEP EXPLORING

Related papers

Improved Pion-Kaon Identification in Heavy-Ion Collisions with a Two-Dimensional Transformation

Accurate identification of charged pions and kaons is essential for precision measurements in relativistic heavy-ion collisions, but becomes increasingly challenging at intermediate and high transverse momentum because of the increasing overlap of the TPC and TOF particle identification responses. In this work, we quantitatively benchmark a two-dimensional shift-and-rotation PID procedure that combines the $nσ_π$ and mass-squared $(m^{2})$ information. The benchmark is performed using Au+Au collision events generated with the AMPT model, where the detector response is modeled using $p_{T}$-dependent PID parameters extracted from STAR data. Since the true particle identities and input yields are known in AMPT but are not used during the reconstruction, the procedure can be evaluated through a direct closure test that is not possible with experimental data alone. The two-dimensional procedure is compared with a reference one-dimensional method consisting of an $|nσ_π|<$ 3 preselection followed by a Gaussian fit to the $m^{2}$ distribution. While both methods perform well when pion and kaon PID responses are well separated, the two-dimensional procedure provides improved yield closure as the PID distributions increasingly overlap at high $p_{T}$. The reconstructed-to-input yield ratio remains within 2\% of unity up to $p_T =$ 3 GeV/$c$, whereas the reference one-dimensional procedure shows a larger deviation. Reaction-plane $v_{2}$ closure tests show that both the reference one-dimensional and two-dimensional PID procedures reproduce the AMPT input $v_{2}$ within the statistical uncertainties over the studied $p_{T}$ range. These results demonstrate that the two-dimensional procedure substantially improves the high-$p_{T}$ yield reconstruction without introducing a detectable bias in the extracted $v_{2}$ under the STAR-like detector response considered here.

physics.ins-det↗

Cryogenic Mechanical Loss of GaAs/AlGaAs Crystalline Coatings

Optical coatings with minimal thermal noise are essential for high-precision, laser-based metrology experiments. Substrate-transferred crystalline GaAs/Al$_{0.92}$Ga$_{0.08}$As coatings have the lowest thermal noise for high-reflectivity mirror coatings with $λ=900$ nm -- 12 $μ$m. Time-frequency stabilization experiments have demonstrated that GaAs/AlGaAs mirror coatings have a lower noise floor than amorphous mirror coatings. These mirrors are now being developed at sizes $\ge 300$ mm for gravitational-wave detectors. In order to understand the coating's fundamental loss mechanisms, which cause thermal noise, we have performed the first measurement of the mechanical loss at cryogenic temperatures using a cryogenic, multimodal, gentle nodal suspension system, which operates from 12 K to room temperature. This initial measurement used a silicon substrate whose asymmetry produced excess friction with the nodal support. Accounting for this friction and Akhiezer loss in the substrate and coating, the mechanical loss agrees well with the thermal noise observed in experiments using cryogenic fixed-cavities with GaAs/AlGaAs mirrors.

physics.ins-det↗

Rotating Capacitive System for Measurement of a Third Order Gravity Gradient Based on a Single-Axis Mechanical Oscillator. Part I, Theory

This paper is a feasibility study on a single-axis mechanical oscillator, mounted on a miniature circular rotating platform, that is proposed to be used for measuring a quantity proportional to the second vertical derivative of gravitational acceleration projected onto the oscillator's sensitivity axis. The latter is aligned with the axis of rotation. Part I establishes theoretical feasibility only. Design constraints, quantitative sensitivity, error budgets, and mobile platform performance will be addressed in Part II.

physics.ins-det↗