Searcharxiv⌕ Search

arXiv · 2611.17499

Continuous Cuffless Blood Pressure Estimation Using PPG From Methods to Clinical Translation

Abstract

Continuous blood pressure (BP) monitoring could improve hypertension management by capturing changes that intermittent cuff measurements miss. Photoplethysmography (PPG) is widely explored for cuffless BP estimation because optical sensors are inexpensive, wearable, and already present in many consumer and clinical devices. PPG, however, does not measure arterial pressure: BP is inferred from waveform characteristics or pulse timing, which also depend on vascular tone, arterial stiffness, sensor contact, motion, and individual physiology. This survey reviews PPG-based cuffless BP estimation along the full measurement chain, covering physiological mechanisms, waveform features, pulse arrival time (PAT), pulse transit time (PTT), machine-learning methods, datasets, calibration, validation, deployment, bias, and clinical translation. Studies are assessed by the strength of evidence they provide rather than by reported error alone, with particular attention to subject and temporal leakage, dataset imbalance, calibration dependence and drift, motion artifacts, and the gap between benchmark accuracy and reliable real-world measurement. The review finds that progress depends on more than better prediction algorithms. Future work should prioritize physiologically informed models, diverse longitudinal datasets, transparent reporting of calibration requirements and failure rates, stronger evaluation protocols, and studies that demonstrate practical value in clinical care.

Explore related subjects

Keep this discovery

Explore connections, maps & timelines

BibTeXRIS

Karthika Shalini Potail, Harshitha Manjunatha, Hetvi Kotadia, Tooraj Nikoubin. 2026-11-12. Continuous Cuffless Blood Pressure Estimation Using PPG From Methods to Clinical Translation. https://searcharxiv.com/abs/2611.17499

Citations retain the original authors and DOI and include this site’s record URL. If this discovery service contributed to your research, you can also cite Searcharxiv by Indiciae: BibTeX · RIS.

KEEP EXPLORING

Related papers

MASQ: Measurement-Adaptive Sampling for Near-Clifford Quantum Error Correction Circuits

Classical sampling of quantum error correction (QEC) circuits supports fault-tolerant protocol evaluation, but estimating rare logical failures requires many independent shots. Frame-active-state simulators isolate non-stabilizer information in a dense active-state vector, yet dense-state processing remains exponential in the active width. This paper presents MASQ, an exact measurement-adaptive sampler for near-Clifford QEC circuits based on selective materialization of non-Clifford rotations. At each measurement boundary, MASQ materializes only rotations in a measurement-relevant closure capturing direct and indirect non-commuting dependencies, deferring the rest to limit active-state expansion. Stabilizer-assisted elimination further removes rotations certified to be invisible to all future measurements. A circuit-dependent schedule is computed once and shared across shots, while adaptive caching of conditional Born probabilities and batched execution reduce repeated sampling work while preserving the measurement-record distribution. Across 19 QEC benchmarks, MASQ reduces peak active width by up to 40 active virtual qubits and achieves up to 8,098-fold CPU throughput speedup over Clifft on multi-round circuits.

cs.ET↗

Automated-Truck Penetration Shapes Human Drivers' Car-Following Margins Near Motorway Ramps: A Driving-Simulator Study

Automated-vehicle dedicated lanes (AVDLs) are proposed as transitional infrastructure for mixed traffic, but their effect near ramps, and that of automated trucks, on the human drivers sharing the road has rarely been observed. In a mixed-design driving-simulator experiment, 63 drivers were assigned to one of four layouts (an AVDL extending beyond, coinciding with, or ending inside a 1.5-km ramp weaving section, or no AVDL) and drove at four automated-truck penetration levels from 20% to 80%. Linear mixed-effects models with participant random effects and multiplicity control were used. Higher penetration reduced the share of car-following time at gaps below 1.5 s from 28.5% to 18.1% (Holm-adjusted p = .006). This was explained by leader composition: drivers spent 8% of following time behind a truck at 20% penetration and 48% at 80%, kept longer gaps behind trucks, and did not change their gaps within leader type. AVDL layout had no detectable effect on safety margins, rear-end conflict rates, travel time or speed (differences bounded within plus or minus 5 s per section) and no significant effect on workload. Between-driver differences accounted for 52% to 77% of the variance in the main outcomes. Mixed-traffic models should therefore represent human car-following as leader-type-dependent and heterogeneous.

cs.ET↗

Countering Anion Inhibition of Laccase Electron Transfer: Electrostatic Design, Charge-Transfer Dynamics on a Superconducting Quantum Processor, and Its Limits

Hydroxide at neutral-to-alkaline pH and halides inhibit fungal laccases and limit their use in wastewater treatment. From GFN2-xTB cluster models of Trametes versicolor laccase (PDB 1GYC) we build a four-site Hubbard model of the His454-T3A-T3B-His452 junction of the trinuclear copper cluster and execute its charge-transfer dynamics on the Euro-Q-Exa quantum computer (IQM, 8 qubits, Trotterized circuits with Pauli twirling; 726 jobs). The charge-transfer frequency is measured to 3-5 meV, reproducibly over nine days and across changes of the device qubit map: hydroxide raises the charge-transfer energy of the crystal-geometry model by 92.0 +/- 2.2 meV (exact 87) and exceeds fluoride by 10.1 +/- 1.8 meV. A screen of charged probes in three dielectric models identifies Y116E; in the probe model the hardware resolves a reduction of the hydroxide penalty by 74 +/- 7 meV and of the halide penalty by 64 +/- 5 meV, acting on the site-energy gap rather than on the coupling. A real Glu116 (five conformers) with PROPKA protonation states and the coupled Asp456 gives a realistic reduction of 10-30 meV, with the same sign in 28 of 28 model combinations; the direction and ordering are the prediction, rate factors only an illustration. Scanning the on-site repulsion reverses the sign of the hydroxide effect, and a one-electron Hartree model reproduces the reversal: the measured dynamics is effectively single-particle. On a Fermi-Hubbard benchmark the hardware does not resolve electron correlation; it would need a contrast loss below 0.13 percent per CZ gate instead of the measured 0.34-0.54 percent.

cs.ET↗