Searcharxiv⌕ Search

arXiv · 2611.26907

A High-Compression Transformer VAE for Efficient and Controllable 3D Medical Image Generation with Diffusion Transformers

Abstract

Many medical image processing tasks, such as completing missing regions or correcting acquisition artifacts, can be cast as volumetric generation conditioned on observations of the same patient. Diffusion Transformers offer scalable capacity and flexible conditioning for this setting, but they operate on a learned image representation that must preserve fine anatomical and pathological detail while keeping complete three-dimensional volumes tractable. We bring Transformer variational autoencoding and multimodal diffusion together to address this challenge. Trained on BrainTumor-256K, a 249M Transformer VAE encodes and decodes $256^3$ volumes 7.6x faster than a comparably sized CNN trained on the same collection. Their PSNR difference is near zero with training-sized crop inputs, but the Transformer leads by 0.749 dB with full-volume inputs and an unchanged scoring region. Increasing Transformer capacity to 499M improves PSNR across all four brain MRI evaluation sets while retaining 3.8x lower encoding-decoding latency than the CNN. Fast encoding also allows conditions to be constructed dynamically in image space during latent diffusion training. Within the compressed representation, a shared Diffusion Transformer integrates text and spatial references for volumetric synthesis, completion and restoration. The brain-trained autoencoder further transfers to non-brain MRI and CT without target-domain fine-tuning, extending its use beyond the anatomy and modality on which it was learned. The framework provides a reusable representation and conditioning interface for efficient, controllable medical image generation. Code is available at https://github.com/OncoMMAI/brainmri-vit-vae3d.

Explore related subjects

Keep this discovery

Explore connections, maps & timelines

BibTeXRIS

Bo Liu, Bingliang Zhang, Yubo Wang, Yunxiang Li, Yang Yang, Janine M. Lupo, Hui Lin. 2026-11-19. A High-Compression Transformer VAE for Efficient and Controllable 3D Medical Image Generation with Diffusion Transformers. https://searcharxiv.com/abs/2611.26907

Citations retain the original authors and DOI and include this site’s record URL. If this discovery service contributed to your research, you can also cite Searcharxiv by Indiciae: BibTeX · RIS.

KEEP EXPLORING

Related papers

Particle picking with an earth mover's seminorm

Particle picking is a key step in single-particle cryo-electron microscopy. It is a challenging task where tomographic projections of proteins and other macromolecules are identified in extremely noisy images. In this work, we introduce a particle picker based on a seminorm defined in terms of a fast wavelet approximation to the earth mover's distance. Our picker is template-free, self-supervised and does not require any prior knowledge of the molecules of interest other than their approximate size. We test it on three public datasets and show that it achieves state-of-the-art reconstructions.

eess.IV↗

FM4SAR-Bench 1.0: Towards A Fair Benchmark for Evaluating Foundation Models for SAR Image Interpretation

Foundation models have advanced SAR image interpretation but created a heterogeneous, fragmented model ecosystem. Existing models differ substantially in their input, training data, objectives, architectures, and release policy, yet the field lacks a unified taxonomy and comparative framework. Current evaluations rely primarily on task-specific benchmarks, which are ill-suited to fair comparison among models with fundamentally different input-output formats and task paradigms, and often overlook data transparency, reproducibility, interpretability, and deployment readiness. Limited SAR data accessibility also means high reported performance does not guarantee access to training data, code, or weights, limiting reproduction, benchmarking, and deployment. To address these issues, we propose a systematic taxonomy and hierarchical evaluation framework for SAR-related foundation models: five rating levels, six dimensions, and fine-grained criteria, with separate protocols for VFMs and VLMs. Beyond overall ratings, it yields interpretable multidimensional capability profiles and supports user-defined weighting, so rankings follow user priorities. Utilizing a fixed auxiliary multimodal large language model in combination with human review, we conduct a systematic meta-analysis and multidimensional assessment of 76 VFMs and 40 VLMs. In terms of SAR benchmark task performance under our framework, SAR-native VLMs do not significantly outperform remote sensing VLMs pretrained on mixed multimodal corpora in which SAR is one of several modalities. This lack of clear advantage is largely due to data availability: large-scale, high-quality, public annotated SAR data remain scarce, restricting both model and training-data scale for SAR-native models. The framework provides a structured basis for requirement-aware model selection and remains extensible as new models emerge.

eess.IV↗

Dem2TA: Beyond Pixels, Towards Perception

Task-oriented image signal processors (ISPs) adapt RAW-to-RGB processing for downstream perception. However, explicit demosaicing is often simplified, kept fixed, or optimized primarily for reconstruction quality, leaving this stage insufficiently integrated into task adaptation. We propose \textbf{Dem2TA}, a framework that incorporates fidelity-supervised demosaicing into the adaptation of the perception pipeline. Starting from a pretrained demosaicing model, we jointly adapt the reconstruction frontend and downstream network using reconstruction and task supervision, together with complementary semantic and task representation alignment. We then freeze the adapted frontend and jointly optimize a lightweight local ISP with the downstream model to refine task-specific rendering without changing the reconstructed linear RGB. Experiments on synthetic RAW detection and box-prompted segmentation demonstrate the effectiveness of representation-guided joint adaptation and subsequent local rendering. Evaluation on a manually verified real-capture dataset further supports transfer beyond synthetic inputs. Compared with TA-ISP on the same adapted foundation, Dem2TA improves detection AP by 0.46 points and segmentation IoU by 1.06 points on synthetic COCO RAW, and segmentation IoU by 0.63 points on real captures.

eess.IV↗