arXiv · hep-ex/0110083
A combined analysis technique for the search for fast magnetic monopoles with the MACRO detector
Abstract
We describe a search method for fast moving ($β> 5 \times 10^{-3}$) magnetic monopoles using simultaneously the scintillator, streamer tube and track-etch subdetectors of the MACRO apparatus. The first two subdetectors are used primarily for the identification of candidates while the track-etch one is used as the final tool for their rejection or confirmation. Using this technique, a first sample of more than two years of data has been analyzed without any evidence of a magnetic monopole. We set a 90% CL upper limit to the local monopole flux of $1.5 \times 10^{-15} cm^{-2} s^{-1} sr^{-1}$ in the velocity range $5 \times 10^{-3} \le β\le 0.99$ and for nucleon decay catalysis cross section smaller than $\sim 1 mb$.
Explore related subjects
Keep this discovery
Explore connections, maps & timelines
The MACRO Collaboration. 2001-10-31. A combined analysis technique for the search for fast magnetic monopoles with the MACRO detector. https://doi.org/10.1016/s0927-6505(01)00183-9
Cite the original work for its findings. Save a collection to share your selection of sources.