arXiv · nucl-ex/0701004
Characterization of the first true coaxial 18-fold segmented n-type prototype detector for the GERDA project
Abstract
The first true coaxial 18-fold segmented n-type HPGe prototype detector produced by Canberra-France for the GERDA neutrinoless double beta-decay project was tested both at Canberra-France and at the Max-Planck-Institut fuer Physik in Munich. The main characteristics of the detector are given and measurements concerning detector properties are described. A novel method to establish contacts between the crystal and a Kapton cable is presented.
Explore related subjects
Keep this discovery
Explore connections, maps & timelines
I. Abt, A. Caldwell, D. Gutknecht, K. Kröninger, M. Lampert, X. Liu, B. Majorovits, D. Quirion, F. Stelzer, P. Wendling. 2007-01-04. Characterization of the first true coaxial 18-fold segmented n-type prototype detector for the GERDA project. https://doi.org/10.1016/j.nima.2007.03.035
Cite the original work for its findings. Save a collection to share your selection of sources.