arXiv · physics/0503111
Accuracy of an Atomic Microwave Power Standard
Abstract
We have built an atomic microwave power standard based on the electromagnetic interaction with laser-cooled atoms. The atoms traversed a waveguide transmission line, and under the effect of the radiation, the internal state populations underwent a Rabi flopping oscillation. Measurement of the oscillation frequency allowed the determination of the incident microwave power. As many of 60 oscillations were observed over a dynamic range of 20 dB and the standard deviation of the measurements was about 0.02%. The measured frequency was compared to a calculated one and an agreement of 1.3% with an uncertainty of 5% (rectangular) was found.
Explore related subjects
Keep this discovery
David C. Paulusse, Nelson L. Rowell, Alain Michaud. 2005-03-23. Accuracy of an Atomic Microwave Power Standard. https://arxiv.org/abs/physics/0503111
Cite the original work for its findings. Save a collection to share your selection of sources.