Searcharxiv⌕ Search

arXiv · physics/0603231

High Voltage Test Apparatus for a Neutron EDM Experiment and Lower Limit on the Dielectric Strength of Liquid Helium at Large Volumes

Abstract

A new search for a permanent electric dipole moment (EDM) of the neutron is underway using ultracold neutrons produced and held in a bath of superfluid helium. Attaining the target sensitivity requires maintaining an electric field of several tens of kilovolts per centimeter across the experimental cell, which is nominally 7.5 cm wide and will contain about 4 liters of superfluid. The electrical properties of liquid helium are expected to be sufficient to meet the design goals, but little is known about these properties for volumes and electrode spacings appropriate to the EDM experiment. Furthermore, direct application of the necessary voltages from an external source to the experimental test cell is impractical. An apparatus to amplify voltages in the liquid helium environment and to test the electrical properties of the liquid for large volumes and electrode spacings has been constructed. The device consists of a large-area parallel plate capacitor immersed in a 200 liter liquid helium dewar. Preliminary results show the breakdown strength of normal state liquid helium is at least 90 kV/cm at these volumes, at the helium vapor pressure corresponding to 4.38 K. These fields hold for more than 11 hours with leakage currents less than 170 pA (about 20% of the maximum tolerable in the EDM experiment). The system is also found to be robust against anticipated radiation backgrounds. Preliminary results for superfluid show that fields of at least 30 kV/cm can be sustained at the volumes required for the EDM experiment, about 60% of the design goal. These results are likely limited by the low pressure that must be maintained above the superfluid bath.

Explore related subjects

Keep this discovery

Explore connections, maps & timelines

BibTeXRIS

J. C. Long, P. D. Barnes, J. G. Boissevain, D. J. Clark, M. D. Cooper, J. J. Gomez, S. K. Lamoreaux, R. E. Mischke, S. I. Penttila. 2006-03-27. High Voltage Test Apparatus for a Neutron EDM Experiment and Lower Limit on the Dielectric Strength of Liquid Helium at Large Volumes. https://arxiv.org/abs/physics/0603231

Cite the original work for its findings. Save a collection to share your selection of sources.

KEEP EXPLORING

Related papers

A Low-Complexity 200 Mbit/s Full-Duplex Digital Link Over a Single Coaxial Cable for Laboratory Instrumentation

Modern full-duplex communication systems, such as Gigabit Ethernet, enable high data rates over challenging transmission media but require sophisticated circuitry and non-trivial digital interfaces. For laboratory instrumentation, the objective may instead be to achieve moderate-bandwidth full-duplex communication over short, well-controlled coaxial cables with minimal circuit and interface complexity. We present a low-complexity bidirectional digital interconnect that enables simultaneous transmission and reception of baseband logic signals over a single coaxial cable. The circuit combines a discrete passive resistive hybrid providing line termination and directional separation, a single logic gate as line driver, and a commercial differential receiver used as a comparator. No modulation, transformer coupling, adaptive calibration, or active analog or digital echo cancellation is required. The design target is full-duplex operation at 200 MBit/s over 10 m of standard RG-178 cable. An analytical treatment of the hybrid network determines the system parameter that maximizes the differential signal amplitude at the receiver, while circuit simulations predict the deterministic timing errors resulting from imperfect directional separation. Experimental measurements confirm the predicted deterministic jitter and show good agreement with the simulation results. For typical laboratory coaxial cables up to 10 m, the measured peak-to-peak edge timing error remains below 1.2 ns. A bidirectional transmission experiment with randomized data demonstrates a clearly open eye diagram. It was found that the transceiver inherently provides loopback functionality when the transmission line is left open. The proposed approach provides a simple, protocol-independent bidirectional physical link which may be useful in laboratory instrumentation where cable routing is constrained.

physics.ins-det↗

Photoluminescence of resin-based solder flux residue under ultraviolet excitation from 120 nm to 310 nm

Nuisance photoluminescence is a potential source of background in particle detectors that use noble liquids as target material for galactic dark matter particles and neutrinos. Liquid argon and xenon scintillate in the vacuum ultraviolet (VUV) wavelength range in response to particle interactions. Photoluminescent materials that absorb these photons can cause unexpected signals that may impede event reconstruction in these detectors. We illuminated residue from different types of commercial solder flux commonly used in liquid xenon detectors with ultraviolet and VUV light and measured their photoluminescence spectra and intensities. We find that all tested flux residues photoluminesce in the visible spectral region when exposed to VUV light.

physics.ins-det↗

A toy model for understanding the space-point resolution of silicon pixel detectors with digital readout

Silicon pixel detectors are widely used in high-energy physics experiments as tracking detectors close to the primary interaction vertex. They provide excellent space-point resolution together with fast electronic readout. Many of them employ only digital (binary) readout which makes the applicability of centre-of-gravity algorithms less obvious. Charge sharing between neighboring pixels improves the resolution beyond the single-pixel limit, but in practice there is a lack of quantitative understanding of the achievable gains. This work provides a simplified analytical and numerical model with which the maximum improvement achievable through charge sharing is quantified for both one and two-dimensional pixel geometries. A phenomenological parameterisation of the resolution as a function of the average cluster size is derived and compared to experimental data from several detector technologies.

physics.ins-det↗