SearcharxivSearch

arXiv subjects

A. Eichler

Publications and source records attributed to A. Eichler.

At least 19 recordsLinked to original sources

2024 Roadmap on Magnetic Microscopy Techniques and Their Applications in Materials Science

Considering the growing interest in magnetic materials for unconventional computing, data storage, and sensor applications, there is active research not only on material synthesis but also characterisation of their properties. In addition to structural and integral magnetic characterisations, imaging of magnetization patterns, current distributions and magnetic fields at nano- and microscale is of major importance to understand the material responses and qualify them for specific applications. In this roadmap, we aim to cover a broad portfolio of techniques to perform nano- and microscale magnetic imaging using SQUIDs, spin center and Hall effect magnetometries, scanning probe microscopies, x-ray- and electron-based methods as well as magnetooptics and nanoMRI. The roadmap is aimed as a single access point of information for experts in the field as well as the young generation of students outlining prospects of the development of magnetic imaging technologies for the upcoming decade with a focus on physics, materials science, and chemistry of planar, 3D and geometrically curved objects of different material classes including 2D materials, complex oxides, semi-metals, multiferroics, skyrmions, antiferromagnets, frustrated magnets, magnetic molecules/nanoparticles, ionic conductors, superconductors, spintronic and spinorbitronic materials.

cond-mat.mtrl-sci

Spin detection via parametric frequency conversion in a membrane resonator

Recent demonstrations of ultracoherent nanomechanical resonators introduce the prospect of new protocols for solid state sensing applications. Here, we propose to use two coupled ultracoherent resonator modes on a Si$_3$N$_4$ membrane for the detection of small nuclear spin ensembles. To this end, we employ parametric frequency conversion between nondegenerate modes. The nondegenerate modes result from coupled degenerate resonators, and the parametric conversion is mediated by periodic inversions of the nuclear spins in the presence of a magnetic scanning tip. We analyze potential noise sources and derive the achievable signal-to-noise ratio with typical experimental parameter values. Our proposal reconciles the geometric constraints of optomechanical systems with the requirements of scanning force microscopy and brings forth a new platform for spin-phonon interaction and spin imaging.

physics.app-ph

Magnetic resonance force microscopy with a one-dimensional resolution of 0.9 nanometers

Magnetic resonance force microscopy (MRFM) is a scanning probe technique capable of detecting MRI signals from nanoscale sample volumes, providing a paradigm-changing potential for structural biology and medical research. Thus far, however, experiments have not reached suffcient spatial resolution for retrieving meaningful structural information from samples. In this work, we report MRFM imaging scans demonstrating a resolution of 0.9 nm and a localization precision of 0.6 nm in one dimension. Our progress is enabled by an improved spin excitation protocol furnishing us with sharp spatial control on the MRFM imaging slice, combined with overall advances in instrument stability. From a modeling of the slice function, we expect that our arrangement supports spatial resolutions down to 0.3 nm given suffcient signal-to-noise ratio. Our experiment demonstrates the feasibility of sub-nanometer MRI and realizes an important milestone towards the three-dimensional imaging of macromolecular structures.

physics.app-ph

Gate-controlled phase switching in a Parametron

The parametron, a resonator-based logic device, is a promising physical platform for emerging computational paradigms. When the parametron is subject to both parametric pumping and external driving, complex phenomena arise that can be harvested for applications. In this paper, we experimentally demonstrate deterministic phase switching of a parametron by applying frequency tuning pulses. To our surprise, we find different regimes of phase switching due to the interplay between a parametric pump and an external drive. We provide full modeling of our device with numerical simulations and find excellent agreement between model and measurements. Our result opens up new possibilities for fast and robust logic operations within large-scale parametron architectures.

cond-mat.mes-hall

A parametric symmetry breaking transducer

Force detectors rely on resonators to transduce forces into a readable signal. Usually these resonators operate in the linear regime and their signal appears amidst a competing background comprising thermal or quantum fluctuations as well as readout noise. Here, we demonstrate that a parametric symmetry breaking transduction leads to a novel and robust nonlinear force detection in the presence of noise. The force signal is encoded in the frequency at which the system jumps between two phase states which are inherently protected against phase noise. Consequently, the transduction effectively decouples from readout noise channels. For a controlled demonstration of the method, we experiment with a macroscopic doubly-clamped string. Our method provides a promising new paradigm for high-precision force detection.

cond-mat.mes-hall

Nanoladder cantilevers made from diamond and silicon

We present a "nanoladder" geometry that minimizes the mechanical dissipation of ultrasensitive cantilevers. A nanoladder cantilever consists of a lithographically patterned scaffold of rails and rungs with feature size $\sim$ 100 nm. Compared to a rectangular beam of the same dimensions, the mass and spring constant of a nanoladder are each reduced by roughly two orders of magnitude. We demonstrate a low force noise of $158 (+62)(-42)\,$zN and $190 (+42)(-33)\,$zN in a one-Hz bandwidth for devices made from silicon and diamond, respectively, measured at temperatures between 100--150 mK. As opposed to bottom-up mechanical resonators like nanowires or nanotubes, nanoladder cantilevers can be batch-fabricated using standard lithography, which is a critical factor for applications in scanning force microscopy.

cond-mat.mes-hall

Nanoscale imaging of current density with a single-spin magnetometer

Charge transport in nanostructures and thin films is fundamental to many phenomena and processes in science and technology, ranging from quantum effects and electronic correlations in mesoscopic physics, to integrated charge- or spin-based electronic circuits, to photoactive layers in energy research. Direct visualization of the charge flow in such structures is challenging due to their nanometer size and the itinerant nature of currents. In this work, we demonstrate non-invasive magnetic imaging of current density in two-dimensional conductor networks including metallic nanowires and carbon nanotubes. Our sensor is the electronic spin of a diamond nitrogen-vacancy center attached to a scanning tip. Using a differential measurement technique, we detect DC currents down to a few uA above a baseline current density of 2e4 A/cm2. Reconstructed images have a spatial resolution of typically 50 nm, with a best-effort value of 22 nm. Current density imaging offers a new route for studying electronic transport and conductance variations in two-dimensional materials and devices, with many exciting applications in condensed matter physics.

cond-mat.mes-hall

Ultrasensitive mechanical detection of magnetic moment using a commercial disk drive write head

Sensitive detection of weak magnetic moments is an essential capability in many areas of nanoscale science and technology, including nanomagnetism, quantum readout of spins, and nanoscale magnetic resonance imaging. Here, we show that the write head of a commercial hard drive may enable significant advances in nanoscale spin detection. By approaching a sharp diamond tip to within 5 nm from the pole and measuring the induced diamagnetic moment with a nanomechanical force transducer, we demonstrate a spin sensitivity of 0.032 Bohr magnetons per root Hz, equivalent to 21 proton magnetic moments. The high sensitivity is enabled in part by the pole's strong magnetic gradient of up to 28 million Tesla per meter and in part by the absence of non-contact friction due to the extremely flat writer surface. In addition, we demonstrate quantitative imaging of the pole field with about 10 nm spatial resolution. We foresee diverse applications for write heads in experimental condensed matter physics, especially in spintronics, ultrafast spin manipulation, and mesoscopic physics.

cond-mat.mes-hall

Parametric symmetry breaking in a nonlinear resonator

Much of the physical world around us can be described in terms of harmonic oscillators in thermodynamic equilibrium. At the same time, the far from equilibrium behavior of oscillators is important in many aspects of modern physics. Here, we investigate a resonating system subject to a fundamental interplay between intrinsic nonlinearities and a combination of several driving forces. We have constructed a controllable and robust realization of such a system using a macroscopic doubly clamped string. We experimentally observe a hitherto unseen double hysteresis in both the amplitude and the phase of the resonator's response function and present a theoretical model that is in excellent agreement with the experiment. Our work provides a thorough understanding of the double-hysteretic response through a symmetry breaking of parametric phase states that elucidates the selection criteria governing transitions between stable solutions. Our study motivates applications ranging from ultrasensitive force detection to low-energy computing memory units.

cond-mat.mes-hall

Accelerated nanoscale magnetic resonance imaging through phase multiplexing

We report a method for accelerated nanoscale nuclear magnetic resonance imaging by detecting several signals in parallel. Our technique relies on phase multiplexing, where the signals from different nuclear spin ensembles are encoded in the phase of an ultrasensitive magnetic detector. We demonstrate this technique by simultaneously acquiring statistically polarized spin signals from two different nuclear species (1H, 19F) and from up to six spatial locations in a nanowire test sample using a magnetic resonance force microscope. We obtain one-dimensional imaging resolution better than 5 nm, and subnanometer positional accuracy.

cond-mat.mes-hall

Symmetry breaking in a mechanical resonator made from a carbon nanotube

Nanotubes behave as semi-flexible polymers in that they can bend by a sizeable amount. When integrating a nanotube in a mechanical resonator, the bending is expected to break the symmetry of the restoring potential. Here we report on a new detection method that allows us to demonstrate such symmetry breaking. The method probes the motion of the nanotube resonator at nearly zero-frequency; this motion is the low-frequency counterpart of the second overtone of resonantly excited vibrations. We find that symmetry breaking leads to the spectral broadening of mechanical resonances, and to an apparent quality factor that drops below 100 at room temperature. The low quality factor at room temperature is a striking feature of nanotube resonators whose origin has remained elusive for many years. Our results shed light on the role played by symmetry breaking in the mechanics of nanotube resonators.

cond-mat.mes-hall

Ultrasensitive force detection with a nanotube mechanical resonator

Since the advent of atomic force microscopy, mechanical resonators have been used to study a wide variety of phenomena, such as the dynamics of individual electron spins, persistent currents in normal metal rings, and the Casimir force. Key to these experiments is the ability to measure weak forces. Here, we report on force sensing experiments with a sensitivity of 12 zN Hz^(-1/2) at a temperature of 1.2 K using a resonator made of a carbon nanotube. An ultra-sensitive method based on cross-correlated electrical noise measurements, in combination with parametric downconversion, is used to detect the low-amplitude vibrations of the nanotube induced by weak forces. The force sensitivity is quantified by applying a known capacitive force. This detection method also allows us to measure the Brownian vibrations of the nanotube down to cryogenic temperatures. Force sensing with nanotube resonators offers new opportunities for detecting and manipulating individual nuclear spins as well as for magnetometry measurements.

cond-mat.mes-hall

Strong coupling between mechanical modes in a nanotube resonator

We report on the nonlinear coupling between the mechanical modes of a nanotube resonator. The coupling is revealed in a pump-probe experiment where a mode driven by a pump force is shown to modify the motion of a second mode measured with a probe force. In a second series of experiments, we actuate the resonator with only one oscillating force. Mechanical resonances feature exotic lineshapes with reproducible dips, peaks, and jumps when the measured mode is commensurate with another mode with a frequency ratio of either 2 or 3. Conventional lineshapes are recovered by detuning the frequency ratio using the voltage on a nearby gate electrode. The exotic lineshapes are attributed to strong coupling between the mechanical modes. The possibility to control the strength of the coupling with the gate voltage holds promise for various experiments, such as quantum manipulation, mechanical signal processing, and the study of the quantum-toclassical transition.

cond-mat.mes-hall

A Mechanical Mass Sensor with Yoctogram Resolution

Nanoelectromechanical systems (NEMS) have generated considerable interest as inertial mass sensors. NEMS resonators have been used to weigh cells, biomolecules, and gas molecules, creating many new possibilities for biological and chemical analysis [1-4]. Recently, NEMS-based mass sensors have been employed as a new tool in surface science in order to study e.g. the phase transitions or the diffusion of adsorbed atoms on nanoscale objects [5-7]. A key point in all these experiments is the ability to resolve small masses. Here we report on mass sensing experiments with a resolution of 1.7 yg (1 yg = 10^-24 g), which corresponds to the mass of one proton, or one hydrogen atom. The resonator is made of a ~150 nm long carbon nanotube resonator vibrating at nearly 2 GHz. The unprecedented level of sensitivity allows us to detect adsorption events of naphthalene molecules (C10H8) and to measure the binding energy of a Xe atom on the nanotube surface (131 meV). These ultrasensitive nanotube resonators offer new opportunities for mass spectrometry, magnetometry, and adsorption experiments.

cond-mat.mes-hall

Dissipative and conservative nonlinearity in carbon nanotube and graphene mechanical resonators

Graphene and carbon nanotubes represent the ultimate size limit of one and two-dimensional nanoelectromechanical resonators. Because of their reduced dimensionality, graphene and carbon nanotubes display unusual mechanical behavior; in particular, their dynamics is highly nonlinear. Here, we review several types of nonlinear behavior in resonators made from nanotubes and graphene. We first discuss an unprecedented scenario where damping is described by a nonlinear force. This scenario is supported by several experimental facts: (i) the quality factor varies with the amplitude of the motion as a power law whose exponent coincides with the value predicted by the nonlinear damping model, (ii) hysteretic behavior (of the motional amplitude as a function of driving frequency) is absent in some of our resonators even for large driving forces, as expected when nonlinear damping forces are large, and (iii) when we quantify the linear damping force (by performing parametric excitation measurements) we find that it is significantly smaller than the nonlinear damping force. We then review parametric excitation measurements, an alternative actuation method which is based on nonlinear dynamics. Finally, we discuss experiments where the mechanical motion is coupled to electron transport through a nanotube. The coupling can be made so strong that the associated force acting on the nanotube becomes highly nonlinear with displacement and velocity. Overall, graphene and nanotube resonators hold promise for future studies on classical and quantum nonlinear dynamics.

cond-mat.mes-hall

Gate-tunable split Kondo effect in a carbon nanotube quantum dot

We show a detailed investigation of the split Kondo effect in a carbon nanotube quantum dot with multiple gate electrodes. It is found that the splitting decreases for increasing magnetic field, to result in a recovered zero-bias Kondo resonance at finite magnetic field. Surprisingly, in the same charge state, but under different gate-configurations, the splitting does not disappear for any value of the magnetic field, but we observe an avoided crossing of two high-conductance lines. We think that our observations can be understood in terms of a two-impurity Kondo effect with two spins coupled antiferromagnetically. The exchange coupling between the two spins can be influenced by a local gate, and the non-recovery of the Kondo resonance for certain gate configurations is explained by the existence of a small antisymmetric contribution to the exchange interaction between the two spins.

cond-mat.mes-hall

Nonlinear damping in mechanical resonators based on graphene and carbon nanotubes

Carbon nanotubes and graphene allow fabricating outstanding nanomechanical resonators. They hold promise for various scientific and technological applications, including sensing of mass, force, and charge, as well as the study of quantum phenomena at the mesoscopic scale. Here, we have discovered that the dynamics of nanotube and graphene resonators is in fact highly exotic. We propose an unprecedented scenario where mechanical dissipation is entirely determined by nonlinear damping. As a striking consequence, the quality factor Q strongly depends on the amplitude of the motion. This scenario is radically different from that of other resonators, whose dissipation is dominated by a linear damping term. We believe that the difference stems from the reduced dimensionality of carbon nanotubes and graphene. Besides, we exploit the nonlinear nature of the damping to improve the figure of merit of nanotube/graphene resonators.

cond-mat.mes-hall

Permalloy-based carbon nanotube spin-valve

In this Letter we demonstrate that Permalloy (Py), a widely used Ni/Fe alloy, forms contacts to carbon nanotubes (CNTs) that meet the requirements for the injection and detection of spin-polarized currents in carbon-based spintronic devices. We establish the material quality and magnetization properties of Py strips in the shape of suitable electrical contacts and find a sharp magnetization switching tunable by geometry in the anisotropic magnetoresistance (AMR) of a single strip at cryogenic temperatures. In addition, we show that Py contacts couple strongly to CNTs, comparable to Pd contacts, thereby forming CNT quantum dots at low temperatures. These results form the basis for a Py-based CNT spin-valve exhibiting very sharp resistance switchings in the tunneling magnetoresistance, which directly correspond to the magnetization reversals in the individual contacts observed in AMR experiments.

cond-mat.mes-hall