SearcharxivSearch

arXiv subjects

A. Novosel

Publications and source records attributed to A. Novosel.

3 recordsLinked to original sources

The Imaging Time-of-Propagation Detector at Belle II

We report on the construction, operation, and performance of the Time-of-Propagation detector with imaging used for the Belle II experiment running at the Super-KEKB $e^+e^-$ collider. This detector is located in the central barrel region and uses Cherenkov light to provide particle identification among hadrons. The Cherenkov light is radiated in highly polished bars of synthetic fused silica (quartz) and transported to the ends of the bars via total internal reflection. One bar end is instrumented with finely segmented micro-channel-plate photomultiplier tubes to record the light, while the other end has a mirror attached to reflect the photons back to the instrumented end. Both the propagation times and hit positions of the Cherenkov photons are measured; these depend on the Cherenkov angle and together provide good discrimination among charged pions, kaons, and protons with momenta up to around 4 GeV/$c$. To date, the detector has been used to record and analyze almost 600 fb$^{-1}$ of Belle II data.

hep-ex

Measured and projected beam backgrounds in the Belle II experiment at the SuperKEKB collider

The Belle II experiment at the SuperKEKB electron-positron collider aims to collect an unprecedented data set of $50~{\rm ab}^{-1}$ to study $CP$-violation in the $B$-meson system and to search for Physics beyond the Standard Model. SuperKEKB is already the world's highest-luminosity collider. In order to collect the planned data set within approximately one decade, the target is to reach a peak luminosity of $\rm 6 \times 10^{35}~cm^{-2}s^{-1}$ by further increasing the beam currents and reducing the beam size at the interaction point by squeezing the betatron function down to $\beta^{*}_{\rm y}=\rm 0.3~mm$. To ensure detector longevity and maintain good reconstruction performance, beam backgrounds must remain well controlled. We report on current background rates in Belle II and compare these against simulation. We find that a number of recent refinements have significantly improved the background simulation accuracy. Finally, we estimate the safety margins going forward. We predict that backgrounds should remain high but acceptable until a luminosity of at least $\rm 2.8 \times 10^{35}~cm^{-2}s^{-1}$ is reached for $\beta^{*}_{\rm y}=\rm 0.6~mm$. At this point, the most vulnerable Belle II detectors, the Time-of-Propagation (TOP) particle identification system and the Central Drift Chamber (CDC), have predicted background hit rates from single-beam and luminosity backgrounds that add up to approximately half of the maximum acceptable rates.

hep-ex

Beam background expectations for Belle II at SuperKEKB

The Belle II experiment at the SuperKEKB electron-positron collider aims to collect an unprecedented data set of $\rm 50~{\rm ab}^{-1}$ to study $CP$-violation in the $B$-meson system and to search for Physics beyond the Standard Model (BSM). SuperKEKB is already the world's highest-luminosity collider. In order to collect the planned data set within approximately one decade, the target is to reach a peak luminosity of $\rm 6.3 \times 10^{35}~cm^{-2}s^{-1}$ by further increasing the beam currents and reducing the beam-size at the interaction point by squeezing the betatron function down to $\beta^{*}_{\rm y}=\rm 0.3~mm$. Beam backgrounds are a key challenge in this context. We estimate the expected background evolution in the next ten years and discuss potential challenges and background mitigation strategies. We find that backgrounds will remain high but acceptable until a luminosity of at least $\rm 2.8\times 10^{35}~cm^{-2}s^{-1}$ is reached at $\beta^{*}_{\rm y}=\rm 0.6~mm$. Beyond this luminosity, predictions are highly uncertain, owing to a planned redesign of the interaction region. Improved background estimates with reduced uncertainties for the final, maximum-luminosity operation will require completion of this redesign.

hep-ex