SearcharxivSearch

arXiv · 2504.19090

The Imaging Time-of-Propagation Detector at Belle II

Abstract

We report on the construction, operation, and performance of the Time-of-Propagation detector with imaging used for the Belle II experiment running at the Super-KEKB $e^+e^-$ collider. This detector is located in the central barrel region and uses Cherenkov light to provide particle identification among hadrons. The Cherenkov light is radiated in highly polished bars of synthetic fused silica (quartz) and transported to the ends of the bars via total internal reflection. One bar end is instrumented with finely segmented micro-channel-plate photomultiplier tubes to record the light, while the other end has a mirror attached to reflect the photons back to the instrumented end. Both the propagation times and hit positions of the Cherenkov photons are measured; these depend on the Cherenkov angle and together provide good discrimination among charged pions, kaons, and protons with momenta up to around 4 GeV/$c$. To date, the detector has been used to record and analyze almost 600 fb$^{-1}$ of Belle II data.

Explore related subjects

Keep this discovery

BibTeXRIS

Hulya Atmacan, Matt Belhorn, Yinghui Guan, Longke Li, Bilas Pal, Saurabh Sandilya, Alan Schwartz, Boqun Wang, Shun Watanuki, Matthew Andrew, Matthew Barrett, Martin Bessner, Thomas Browder, J. Bynes, J. Cercillieux, Shawn Dubey, Oskar Hartbrich, Chris Ketter, Brian Kirby, Shahab Kohani, D. Kotchetkov, Luca Macchiarulo, B. Macek, Kurtis Nishimura, H. Purwar, Z. Sang, V. Shebalin, S. Tripathy, Gary Varner, K. Yoshihara, T. Kohriki, X. Wang, S. P. Maharana, V. S. Vismaya, Gerard Visser, Alessandro Gaz, Stefano Lacaprara, R. Stroili, Ezio Torassa, Roberto Mussa, Umberto Tamponi, Peter Krizan, Samo Korpar, Tara Nanut, A. Novosel, Marko Petric, L. Rizzuto, Marko Staric, Lucien Cremaldi, David Sanders, Y. Adachi, Y. Arita, D. Furumura, S. Hara, T. Hayakawa, S. Hirose, Y. Horii, Toru Iijima, Kenji Inami, Y. Ito, Y. Kato, N. Kiribe, R. Koga, K. Kojima, A. Maeda, Y. Maeda, K. Maehara, R. Maeshima, Kodai Matsuoka, G. Muroyama, T. Nakano, R. Okubo, R. Okuto, R. Omori, S. Senga, K. Suzuki, H. Takeichi, N. Tsuzuki, T. Yonekura, R. Conrad, James Fast, Brian Fulsom, Jan Strube, Lynn Wood, I. Danko, T. Gu, N. Herring, N. K. Nisar, S. Roffe, Vladimir Savinov, E. Wang, Vishal Bhardwaj, Alyssa Loos, Milind Purohit, Carl Rosenfeld. 2025-04-27. The Imaging Time-of-Propagation Detector at Belle II. https://doi.org/10.1016/j.nima.2025.170627

Cite the original work for its findings. Save a collection to share your selection of sources.

KEEP EXPLORING

Related papers

Production of Light Nuclei and Hypernuclei in Heavy-Ion Collisions

We review recent STAR and ALICE measurements of light-nucleus and hypernucleus yields, femtoscopic correlations, and collective flow presented at SQM 2026. Statistical-hadronization calculations provide a useful baseline for integrated yields but do not simultaneously describe all measured light-nucleus ratios across collision energies and system sizes. For bound states with mass number $A<4$, current coalescence calculations provide a broadly consistent description of yields, femtoscopic correlations, and collective flow, although the quantitative hypertriton comparison depends on the assumed few-body wave function. The suppressed production of resonant $^{4}$Li relative to compact $^{4}$He indicates an effect of nuclear structure and late-stage dynamics. However, the quantitative model comparison also depends on the treatment of feed-down from unstable states. In high-multiplicity $p$+$p$ collisions, pion-deuteron femtoscopy further indicates that most observed (anti)deuterons are formed through nucleon fusion after strong decays of short-lived resonances. Taken together, these measurements show that production chronology and internal nuclear structure leave measurable imprints on the physics observables.

hep-ex

Search for the process $e^+e^-\to f_1(1285)$ at the SND detector

In the experiment with the SND detector at the VEPP-2000 $e^+e^-$ collider, a search is performed for the direct production of the $C$-even $f_1(1285)$ resonance in $e^+e^-$ collisions. The analysis is based on data with an integrated luminosity of about 200 pb$^{-1}$, accumulated in the center-of-mass energy range of 1.14--1.46 GeV, of which about 72 pb$^{-1}$ were recorded near the maximum of the $f_1(1285)$ resonance. The $f_1(1285)$ production cross section at the resonance maximum $\sigma(e^+e^-\to f_1)=(31\pm 13\pm 2)$ pb and the branching fraction $B(f_1(1285)\to e^+e^-)=(3.5\pm 1.4\pm 0.3)\times 10^{-9}$ have been measured. The significance of the observation of the $e^+e^-\to f_1(1285)$ process is $2.5\sigma$. Since the significance is low, we also present the upper limits at the 90% confidence level: $\sigma(e^+e^-\to f_1)<48\mbox{ pb}$ and $B(f_1(1285)\to e^+e^-)<5.4\times 10^{-9}$.

hep-ex

Projected Sensitivity to Slow Muonphilic Dark Matter with Accelerator Muon Beams

The nature of dark matter (DM) remains one of the most enduring open questions in modern physics, and muonphilic DM has emerged as a promising scenario that complements traditional DM candidates. Following the recently established cosmic-ray muon scattering approach, we investigate the sensitivity for probing slow muonphilic DM with accelerator muon beams. A Geant4-based simulation framework is developed, incorporating the detector geometry from the PKMu muon tomography system and a dedicated elastic $\mu$-DM scattering process. The projected sensitivity is found to be largely insensitive to both the beam energy and the transverse beam size when the beam is fully contained within the detector acceptance. For a benchmark beam intensity of $10^5/\rm{s}$, the simulated pure-muon beam surpasses the existing cosmic-ray limit of $1.61\times10^{-17}$ cm$^2$ at $m_{\rm DM}=1$ GeV within approximately 11 seconds. A realistic muon beam phase-space distribution based on simulations for the High Intensity heavy-ion Accelerator Facility (HIAF) is also implemented, yielding projected limits that improve upon the cosmic-ray results by nearly two orders of magnitude in a one-day exposure. These results demonstrate that a beam-muon scattering experiment offers a robust and promising route toward significantly improved sensitivity to slow muonphilic DM.

hep-ex