Searcharxiv⌕ Search

arXiv subjects

A. Ortiz de Solórzano

Publications and source records attributed to A. Ortiz de Solórzano.

At least 37 records · Page 2Linked to original sources

Li$_2$$^{100\textrm{depl}}$MoO$_4$ Scintillating Bolometers for Rare-Event Search Experiments

We report on the development of scintillating bolometers based on lithium molybdate crystals containing molybdenum depleted in the double-$β$ active isotope $^{100}$Mo (Li$_2$$^{100\textrm{depl}}$MoO$_4$). We used two Li$_2$$^{100\textrm{depl}}$MoO$_4$ cubic samples, 45 mm side and 0.28 kg each, produced following purification and crystallization protocols developed for double-$β$ search experiments with $^{100}$Mo-enriched Li$_2$MoO$_4$ crystals. Bolometric Ge detectors were utilized to register scintillation photons emitted by the Li$_2$$^{100\textrm{depl}}$MoO$_4$ crystal scintillators. The measurements were performed in the CROSS cryogenic set-up at the Canfranc underground laboratory (Spain). We observed that the Li$_2$$^{100\textrm{depl}}$MoO$_4$ scintillating bolometers are characterized by excellent spectrometric performance ($\sim$3--6 keV FWHM at 0.24--2.6 MeV $γ$'s), moderate scintillation signal ($\sim$0.3--0.6 keV/MeV depending on light collection conditions) and high radiopurity ($^{228}$Th and $^{226}$Ra activities are below a few $μ$Bq/kg), comparable to the best reported results of low-temperature detectors based on Li$_2$MoO$_4$ with natural or $^{100}$Mo-enriched molybdenum content. Prospects of Li$_2$$^{100\textrm{depl}}$MoO$_4$ bolometers for use in rare-event search experiments are briefly discussed.

physics.ins-det↗

Purification Efficiency and Radon Emanation of Gas Purifiers used with Pure and Binary Gas Mixtures for Gaseous Dark Matter Detectors

Rare event searches require extreme radiopurity in all detector components. This includes the active medium, which in the case of gaseous detectors, is the operating gas. The gases used typically include noble gas mixtures with molecular quenchers. Purification of these gases is required to achieve the desired detector performance, however, purifiers are known to emanate 222 Rn, which is a potential source of background. Several purifiers are studied for their O 2 and H 2 O purification efficiency and Rn emanation rates, aiming to identify the lowest-Rn options. Furthermore, the absorption of quenchers by the purifiers is assessed when used in a recirculating closed-loop gas system.

physics.ins-det↗

Long term measurement of the $^{222}$Rn concentration in the Canfranc Underground Laboratory

We report the results of six years (2013-2018) of measurements of $^{222}$Rn air concentration, relative humidity, atmospheric pressure and temperature in the halls A, B and C of the Canfranc Underground Laboratory (LSC). We have calculated all the Pearson correlation coefficients among these parameters and we have found a positive correlation between the $^{222}$Rn concentration and the relative humidity. Both correlated variables show a seasonal periodicity. The joint analysis of laboratory data and four years (2015-2018) of the meteorological variables outside the laboratory shows the correlation between the $^{222}$Rn concentration and the outside temperature. The collected information stresses the relevance of designing good Rn-mitigation strategies in current and future experiments at LSC; in particular, we have checked for two years (2017-2018) the good performance of the mitigation procedure of the ANAIS--112 experiment. Finally, in another measurement (2019-2021) for two years of live time, we report an upper limit to the residual $^{222}$Rn content of the radon-free air provided by the radon abatement system installed in the laboratory.

physics.ins-det↗

Machine-learning techniques applied to three-year exposure of ANAIS-112

ANAIS is a direct dark matter detection experiment aiming at the confirmation or refutation of the DAMA/LIBRA positive annual modulation signal in the low energy detection rate, using the same target and technique. ANAIS-112, located at the Canfranc Underground Laboratory in Spain, is operating an array of 3$\times$3 ultrapure NaI(Tl) crystals with a total mass of 112.5 kg since August 2017. The trigger rate in the region of interest (1-6 keV) is dominated by non-bulk scintillation events. In order to discriminate these noise events from bulk scintillation events, robust filtering protocols have been developed. Although this filtering procedure works very well above 2 keV, the measured rate from 1 to 2 keV is about 50% higher than expected according to our background model, and we cannot discard non-bulk scintillation events as responsible of that excess. In order to improve the rejection of noise events, a Boosted Decision Tree has been developed and applied. With this new PMT-related noise rejection algorithm, the ANAIS-112 background between 1 and 2 keV is reduced by almost 30%, leading to an increase in sensitivity to the annual modulation signal. The reanalysis of the three years of ANAIS-112 data with this technique is also presented.

astro-ph.IM↗

Conceptual Design of BabyIAXO, the intermediate stage towards the International Axion Observatory

This article describes BabyIAXO, an intermediate experimental stage of the International Axion Observatory (IAXO), proposed to be sited at DESY. IAXO is a large-scale axion helioscope that will look for axions and axion-like particles (ALPs), produced in the Sun, with unprecedented sensitivity. BabyIAXO is conceived to test all IAXO subsystems (magnet, optics and detectors) at a relevant scale for the final system and thus serve as prototype for IAXO, but at the same time as a fully-fledged helioscope with relevant physics reach itself, and with potential for discovery. The BabyIAXO magnet will feature two 10 m long, 70 cm diameter bores, and will host two detection lines (optics and detector) of dimensions similar to the final ones foreseen for IAXO. BabyIAXO will detect or reject solar axions or ALPs with axion-photon couplings down to $g_{aγ} \sim 1.5 \times 10^{-11}$ GeV$^{-1}$, and masses up to $m_a\sim 0.25$ eV. BabyIAXO will offer additional opportunities for axion research in view of IAXO, like the development of precision x-ray detectors to identify particular spectral features in the solar axion spectrum, and the implementation of radiofrequency-cavity-based axion dark matter setups.

physics.ins-det↗

ANAIS-112 status: two years results on annual modulation

ANAIS (Annual modulation with NaI Scintillators) is a dark matter direct detection experiment located at the Canfranc Underground Laboratory (LSC), in Spain. The goal is to confirm or refute in a model independent way the DAMA/LIBRA positive result: an annual modulation in the low-energy detection rate compatible with the expected signal induced by dark matter particles in the galactic halo. This signal, observed for about 20 years, is in strong tension with the negative results of other very sensitive experiments, but a direct comparison using the same target material, NaI(Tl), was still lacking. ANAIS-112, consisting of 112.5 kg of NaI(Tl) scintillators, is taking data at the LSC since August 2017. Here we present the preliminary annual modulation analysis corresponding to two years of data (exposure of 220.69 kg x y) and the ANAIS-112 projected sensitivity for the scheduled 5 y of operation.

astro-ph.IM↗

Physics potential of the International Axion Observatory (IAXO)

We review the physics potential of a next generation search for solar axions: the International Axion Observatory (IAXO). Endowed with a sensitivity to discover axion-like particles (ALPs) with a coupling to photons as small as $g_{aγ}\sim 10^{-12}$ GeV$^{-1}$, or to electrons $g_{ae}\sim$10$^{-13}$, IAXO has the potential to find the QCD axion in the 1 meV$\sim$1 eV mass range where it solves the strong CP problem, can account for the cold dark matter of the Universe and be responsible for the anomalous cooling observed in a number of stellar systems. At the same time, IAXO will have enough sensitivity to detect lower mass axions invoked to explain: 1) the origin of the anomalous "transparency" of the Universe to gamma-rays, 2) the observed soft X-ray excess from galaxy clusters or 3) some inflationary models. In addition, we review string theory axions with parameters accessible by IAXO and discuss their potential role in cosmology as Dark Matter and Dark Radiation as well as their connections to the above mentioned conundrums.

hep-ph↗

Performance of ANAIS-112 experiment after the first year of data taking

ANAIS is a direct detection dark matter experiment aiming at the study of the annual modulation expected in the interaction rate. It uses same target and technique than DAMA/LIBRA experiment, which reported a highly significant positive modulation compatible with that expected for dark matter particles distributed in the galactic halo. However, other very sensitive experiments do not find any hint of particles with the required properties, although comparison is model dependent. In 2017, ANAIS-112 experiment was installed at the Canfranc Underground Laboratory (LSC), in Spain, and after the commissioning run for calibration and general assessment, ANAIS-112 started data taking in dark matter mode on August 3$^{rd}$, 2017. It consists of nine NaI(Tl) modules, amounting 112.5 kg of mass in total. ANAIS-112 will be able to test the DAMA/LIBRA result with the achieved background and threshold at three sigma level in five years of data taking. Here we report on the experimental apparatus and detector performance after the first year of data taking. Total live time available amounts to 341.72 days, being the corresponding exposure 105.32 kg x yr.

astro-ph.IM↗

ANAIS-112 sensitivity in the search for dark matter annual modulation

The annual modulation measured by the DAMA/LIBRA experiment can be explained by the interaction of dark matter WIMPs in NaI(Tl) scintillator detectors. Other experiments, with different targets or techniques, exclude the region of parameters singled out by DAMA/LIBRA, but the comparison of their results relies on several hypotheses regarding the dark matter model. ANAIS-112 is a dark matter search with 112.5 kg of NaI(Tl) scintillators at the Canfranc Underground Laboratory (LSC) to test the DAMA/LIBRA result in a model independent way. We analyze its prospects in terms of the a priori critical and detection limits of the experiment. A simple figure of merit has been obtained to compare the different experiments looking for the annual modulation observed by DAMA/LIBRA. We conclude that after 5 years of measurement, ANAIS-112 can detect the annual modulation in the 3$σ$ region compatible with the DAMA/LIBRA result.

astro-ph.IM↗

First results on dark matter annual modulation from ANAIS-112 experiment

ANAIS is a direct detection dark matter experiment aiming at the testing of the DAMA/LIBRA annual modulation result, which standing for about two decades has neither been confirmed nor ruled out by any other experiment in a model independent way. ANAIS-112, consisting of 112.5 kg of sodium iodide crystals, is taking data at the Canfranc Underground Laboratory, Spain, since August 2017. This letter presents the annual modulation analysis of 1.5 years of data, amounting to 157.55 kg$\times$y. We focus on the model independent analysis searching for modulation and the validation of our sensitivity prospects. ANAIS-112 data are consistent with the null hypothesis (p-values of 0.65 and 0.16 for [2-6] and [1-6] keV energy regions, respectively). The best fits for the modulation hypothesis are consistent with the absence of modulation ($S_m$=-0.0044$\pm$0.0058 cpd/kg/keV and -0.0015$\pm$0.0063 cpd/kg/keV, respectively). They are in agreement with our estimated sensitivity for the accumulated exposure, supporting our projected goal of reaching a 3$σ$ sensitivity to the DAMA/LIBRA result in 5 years of data taking.

astro-ph.IM↗

Annual modulation of dark matter: The ANAIS-112 case

The annual modulation measured by the DAMA/LIBRA experiment can be explained by the interaction of dark matter WIMPs in NaI(Tl) scintillator detectors. Other experiments, with different targets or techniques, exclude the region of parameters singled out by DAMA/LIBRA, but the comparison of their results relies on several hypotheses regarding the dark matter model. ANAIS-112 is a dark matter search with 112.5 kg of NaI(Tl) scintillators under commissioning at the Canfranc Underground Laboratory (LSC) to test the DAMA/LIBRA result in a model independent way. We analyze its prospects in terms of the a priori critical and detection limits of the experiment. The analysis is based on the detector response and the background level measured for the first modules operated in Canfranc.

astro-ph.IM↗

Light yield determination in large sodium iodide detectors applied in the search for dark matter

Application of NaI(Tl) detectors in the search for galactic dark matter particles through their elastic scattering off the target nuclei is well motivated because of the long standing DAMA/LIBRA highly significant positive result on annual modulation, still requiring confirmation. For such a goal, it is mandatory to reach very low threshold in energy (at or below the keV level), very low radioactive background (at a few counts/keV/kg/day), and high detection mass (at or above the 100 kg scale). One of the most relevant technical issues is the optimization of the crystal intrinsic scintillation light yield and the efficiency of the light collecting system for large mass crystals. In the frame of the ANAIS (Annual modulation with NaI Scintillators) dark matter search project large NaI(Tl) crystals from different providers coupled to two photomultiplier tubes (PMTs) have been tested at the Canfranc Underground Laboratory. In this paper we present the estimates of the NaI(Tl) scintillation light collected using full-absorption peaks at very low energy from external and internal sources emitting gammas/electrons, and single-photoelectron events populations selected by using very low energy pulses tails. Outstanding scintillation light collection at the level of 15~photoelectrons/keV can be reported for the final design and provider chosen for ANAIS detectors. Taking into account the Quantum Efficiency of the PMT units used, the intrinsic scintillation light yield in these NaI(Tl) crystals is above 40~photoelectrons/keV for energy depositions in the range from 3 up to 25~keV. This very high light output of ANAIS crystals allows triggering below 1~keV, which is very important in order to increase the sensitivity in the direct detection of dark matter.

physics.ins-det↗

The ANAIS Dark Matter Project: Status and Prospects

The ANAIS (Annual modulation with NaI(Tl) Scintillators) experiment aims at the confirmation of the DAMA/LIBRA positive annual modulation signal using the same target and technique at the Canfranc Underground Laboratory (LSC). A first step, named ANAIS-25 (two 12.5 kg NaI(Tl) modules) taking data from December 2012 to February 2015, provided interesting outcomes: very high light collection efficiency, that could allow to lower the analysis energy threshold down to the level of 1 keVee, and a good understanding of the different background components, in particular the cosmogenic activated isotopes in the crystal bulk and other radioactive contaminations of the NaI crystal/powder. But those prototypes clearly pointed to the need for improved crystal radiopurity, in particular for $^{210}$Pb contamination. Since then, improvements in the purification and growing procedures in order to reduce background in the very low energy region have been implemented and a new 12.5 kg module has been constructed and installed between the former two crystals, forming the ANAIS-37 setup. Very preliminary results of this setup evidence the improvement on radiopurity of the new crystal and are presented here. In addition, background simulations and prospects for the full experiment are discussed.

astro-ph.IM↗

Status of the ANAIS Dark Matter Project at the Canfranc Underground Laboratory

The ANAIS (Annual modulation with NaI(Tl) Scintillators) experiment aims at the confirmation of the DAMA/LIBRA signal using the same target and technique at the Canfranc Underground Laboratory (LSC). Along 2016, 112.5 kg of ultra pure NaI(Tl) crystals will be installed at LSC in a 3x3 modules matrix configuration. The ANAIS-25 and ANAIS-37 set-ups have been taking data at the LSC testing the detector performance, the DAQ and analysis systems, and assessing the background. Main results coming from both set-ups will be summarized in this paper, focusing on the excellent detector performance and background understanding. Prospects for the experiment will be also briefly revised.

astro-ph.IM↗

Radiopurity assessment of the tracking readout for the NEXT double beta decay experiment

The Neutrino Experiment with a Xenon Time-Projection Chamber (NEXT) is intended to investigate the neutrinoless double beta decay of 136Xe, which requires a severe suppression of potential backgrounds; therefore, an extensive screening and selection process is underway to control the radiopurity levels of the materials to be used in the experimental set-up of NEXT. The detector design combines the measurement of the topological signature of the event for background discrimination with the energy resolution optimization. Separate energy and tracking readout planes are based on different sensors: photomultiplier tubes for calorimetry and silicon multi-pixel photon counters for tracking. The design of a radiopure tracking plane, in direct contact with the gas detector medium, was specially challenging since the needed components like printed circuit boards, connectors, sensors or capacitors have typically, according to available information in databases and in the literature, activities too large for experiments requiring ultra-low background conditions. Here, the radiopurity assessment of tracking readout components based on gamma-ray spectroscopy using ultra-low background germanium detectors at the Laboratorio Subterraneo de Canfranc (Spain) is described. According to the obtained results, radiopure enough printed circuit boards made of kapton and copper, silicon photomultipliers and other required components, fulfilling the requirement of an overall background level in the region of interest of at most 8 10-4 counts keV-1 kg-1 y-1, have been identified.

physics.ins-det↗

Background analysis and status of the ANAIS dark matter project

ANAIS (Annual modulation with NaI Scintillators) is a project aiming to set up at the new facilities of the Canfranc Underground Laboratory (LSC), a large scale NaI(Tl) experiment in order to explore the DAMA/LIBRA annual modulation positive result using the same target and technique. Two 12.5 kg each NaI(Tl) crystals provided by Alpha Spectra took data at the LSC in the ANAIS-25 set-up. The comparison of the background model for the ANAIS-25 prototypes with the experimental results is presented. ANAIS crystal radiopurity goals have been achieved for Th-232 and U-238 chains, but a Pb-210 contamination out-of-equilibrium was identified, whose origin has been studied. The high light collection efficiency obtained with these prototypes allows to anticipate an energy threshold of the order of 1 keVee. A new detector, with improved performances, was received in March 2015 and very preliminary results are shown.

astro-ph.IM↗

Radon and material radiopurity assessment for the NEXT double beta decay experiment

The Neutrino Experiment with a Xenon TPC (NEXT), intended to investigate the neutrinoless double beta decay using a high-pressure xenon gas TPC filled with Xe enriched in 136Xe at the Canfranc Underground Laboratory in Spain, requires ultra-low background conditions demanding an exhaustive control of material radiopurity and environmental radon levels. An extensive material screening process is underway for several years based mainly on gamma-ray spectroscopy using ultra-low background germanium detectors in Canfranc but also on mass spectrometry techniques like GDMS and ICPMS. Components from shielding, pressure vessel, electroluminescence and high voltage elements and energy and tracking readout planes have been analyzed, helping in the final design of the experiment and in the construction of the background model. The latest measurements carried out will be presented and the implication on NEXT of their results will be discussed. The commissioning of the NEW detector, as a first step towards NEXT, has started in Canfranc; in-situ measurements of airborne radon levels were taken there to optimize the system for radon mitigation and will be shown too.

physics.ins-det↗

Cosmogenic radionuclide production in NaI(Tl) crystals

The production of long-lived radioactive isotopes in materials due to the exposure to cosmic rays on Earth surface can be an hazard for experiments demanding ultra-low background conditions, typically performed deep underground. Production rates of cosmogenic isotopes in all the materials present in the experimental set-up, as well as the corresponding cosmic rays exposure history, must be both well known in order to assess the relevance of this effect in the achievable sensitivity of a given experiment. Although NaI(Tl) scintillators are being used in experiments aiming at the direct detection of dark matter since the first nineties of the last century, very few data about cosmogenic isotopes production rates have been published up to date. In this work we present data from two 12.5 kg NaI(Tl) detectors, developed in the frame of the ANAIS project, which were installed inside a convenient shielding at the Canfranc Underground Laboratory just after finishing surface exposure to cosmic rays. The very fast start of data taking allowed to identify and quantify isotopes with half-lives of the order of tens of days. Initial activities underground have been measured and then production rates at sea level have been estimated following the history of detectors; values of about a few tens of nuclei per kg and day for Te isotopes and 22Na and of a few hundreds for I isotopes have been found. These are the first direct estimates of production rates of cosmogenic nuclides in NaI crystals. A comparison of the so deduced rates with calculations using typical cosmic neutron flux at sea level and a carefully selected description of excitation functions will be also presented together with an estimate of the corresponding contribution to the background at low and high energies, which can be relevant for experiments aiming at rare events searches.

physics.ins-det↗