Searcharxiv⌕ Search

arXiv subjects

A. Ortiz de Solórzano

Publications and source records attributed to A. Ortiz de Solórzano.

At least 19 recordsLinked to original sources

Measurement of the $^{39}$Ar specific activity in atmospheric argon with DArT at the Canfranc Underground Laboratory

We report the measurement of the $^{39}$Ar specific activity of atmospheric argon using DArT, a low-background single-phase liquid-argon detector read out by cryogenic silicon photomultipliers, at the Canfranc Underground Laboratory (LSC) in Spain. DArT was first filled with atmospheric argon and then with a sample of underground argon of known radioactivity from the DarkSide-50 experiment. The underground argon serves as a background reference in this measurement, making the result robust because we do not rely on background simulations. We measure the $^{39}$Ar specific activity with both a cut-and-count method and a binned maximum-likelihood fit, yielding consistent results. We obtain $a_{\text{AAr}}= 0.955 \pm 0.008~\text{Bq}/\text{kg}$. This result agrees with previous measurements from other experiments and provides the most precise determination of the $^{39}$Ar specific activity in atmospheric argon to date. It also validates DArT as a key component of the DArTInArDM experiment at LSC, which aims to measure the $^{39}$Ar activity of the argon extracted from deep underground wells in Colorado (USA) for the Darkside-20k and LEGEND-1000 experiments at Laboratori Nazionali del Gran Sasso in Italy.

physics.ins-det↗

The CROSS experiment: detector construction, background projection, and sensitivity to $^{100}$Mo $0\nu2β$ decay

The CROSS experiment to search for neutrinoless double-beta ($0\nu2β$) decay in $^{100}$Mo with the help of an array of scintillating cryogenic calorimeters, containing 4.9 kg of $^{100}$Mo, has been ongoing in a low-background setup at the Canfranc underground laboratory (Spain) since mid-November 2025. In this paper, we present the construction of the CROSS detector and the description of Geant4-based Monte Carlo simulations of expected background in the region of interest. The simulations predict the background index in a 100-keV-wide interval centered at the $Q$-value of $^{100}$Mo (3034 keV) on the level of 3.2(5) $\times$ 10$^{-3}$ cnts/keV/kg/yr. Taking into account an 18% deadtime induced by the muon veto cut and a typical 90% duty cycle of the facility, such background level would allow to reach the world-leading sensitivity to $^{100}$Mo $0\nu2β$ decay (lim $T_{1/2} \sim 4 \times 10^{24}$ yr) in 1 year of data taking. Considering conservatively a factor 3 (10) worse background index due to unpredictable radioactive contamination of construction materials and/or detector performance, a 2-yr-long operation of the CROSS array would be still compatible with the best (competitive) sensitivity to $0\nu2β$ decay in $^{100}$Mo.

physics.ins-det↗

First Experimental Bounds on Transverse Plasmon Solar Axions with ANAIS-112

Solar axion-like particles (ALPs) can be resonantly produced through the conversion of transverse plasmons in the magnetic field of the solar interior, introducing a production mechanism complementary to the conventional Primakoff process. In this Letter, we report the first experimental search for solar ALPs produced through this mechanism. Using an exposure of 625.75 kg$\times$yr from ANAIS-112, we search for the annual modulation of the flux induced by the variation of the Earth--Sun distance, assuming detection through inverse Primakoff conversion in the detector. Modulation amplitudes fitted in 1 keV bins between 1--20 keV are consistent with the absence of modulation, yielding the first constraints on the axion--photon coupling that include the resonant transverse-plasmon flux, $g_{aγ} < 1.32\times 10^{-9} \mathrm{GeV}^{-1}$ (90\% C.L.) at $m_a \simeq 150$ eV. This previously unexplored production channel extends the sensitivity of ANAIS-112 in the mass range 35--280 eV, where, for the expected solar magnetic-field models, the transverse-plasmon flux exceeds the Primakoff flux by up to two orders of magnitude.

hep-ex↗

Low-energy threshold demonstration for dark matter searches in TREX-DM with an $^{37}$Ar source produced at CNA HiSPANoS

We report on the successful implementation of an $^{37}$Ar calibration source in the TREX-DM detector, a high-pressure time projection chamber designed for low-mass dark matter searches. The $^{37}$Ar source was produced through fast neutron activation of CaO powder at the HiSPANoS facility of Centro Nacional de Aceleradores (CNA) in Spain, yielding $O(1)$ kBq of activity. Using a novel combined GEM-Micromegas readout system, we successfully detected both characteristic emissions from $^{37}$Ar decay (2.82 keV and 270 eV) and achieved unprecedented energy threshold performance in TREX-DM, approaching the single-electron ionization energy of argon.

physics.ins-det↗

Status of the HENSA collaboration at the Canfranc Underground Laboratory: results from two years of measurement of the neutron flux in hall B

Thiswork deals with the characterization of the neutron flux in hall B of the CanfrancUnderground Laboratory (LSC) employing the High Efficiency Neutron Spectrometry Array (HENSA). The ultimate goal of this measurement is to set a limit on the corresponding effects of the neutron flux in the background of the ANAIS-112 experiment. The preliminary neutron counting rates of two years of measurement are reported. Various data analysis techniques, including pulse shape discrimination, are discussed. The first results on the spectral reconstruction of the neutron flux are also presented.

physics.ins-det↗

Muon veto system for the CROSS double-beta decay search experiment

In preparation to the CROSS experiment at the Canfranc underground laboratory (Spain) $-$ aiming to search for neutrinoless double-beta ($0νββ$) decay of $^{100}$Mo using low-temperature detectors with heat-scintillation readout $-$ we report on development of a dedicated muon veto system. The need for the muon veto in CROSS is caused by a comparatively high residual cosmic muon flux at the experimental site ($\sim$20 $μ$/m$^2$/h), being a dominant background in the region of interest (ROI) at $\sim$3 MeV. Thus, we installed the muon veto system around the CROSS low-background setup, forming four lateral, one top, and four bottom sectors. In this paper we describe the design, construction and operation of the CROSS muon veto system, as well as its optimization and validation by comparing dedicated Monte Carlo (MC) simulations of muons with low-temperature measurements in the setup. We demonstrate a stable operation of the veto system with the average trigger rates compatible with MC simulations. Also, we investigated two muon trigger logics based on coincidences with either 2 sectors or a single sector of the veto. The MC study shows that, in combination with the multiplicity cut of thermal detectors, these trigger logics allow to reject 99.2\% and 99.7\% of muon-induced events in the ROI, respectively. Despite a comparatively high dead time ($\sim$18\%) introduced by coincidences with any of nine sectors of the veto $-$ the adopted strategy $-$ the muon-induced background in the ROI of the CROSS experiment can be reduced down to $\sim$2 $\times 10^{-3}$ cnts/keV/kg/yr, i.e., an acceptable level compatible with a high-sensitivity $0νββ$ decay search foreseen in CROSS.

physics.ins-det↗

Combined Annual Modulation Dark Matter Search with COSINE-100 and ANAIS-112

The annual modulation signal, claimed to be consistent with dark matter as observed by DAMA/LIBRA in a sodium-iodide based detector, has persisted for over two decades. COSINE-100 and ANAIS-112 were designed to test the claim directly using the same target material. COSINE-100, located at Yangyang Underground Laboratory in South Korea, and ANAIS-112, located at Canfranc Underground Laboratory in Spain, have been taking data since 2016 and 2017, respectively. Each experiment published its respective results independently. In this paper, we present the results of an annual modulation search as a test of the signal observed by DAMA/LIBRA with the first three respective years of data from COSINE-100 and ANAIS-112. Using a Markov Chain Monte Carlo method, we find best fit values for modulation amplitude of $-0.0002 {\pm} 0.0026$ cpd/kg/keV in the 1-6 keV and $0.0021 {\pm} 0.0028$ cpd/kg/keV in the 2-6 keV energy regions. These results are not compatible with DAMA/LIBRA's assertion for their observation of annual modulation at $3.7σ$ and $2.6σ$, respectively. Performing a simple combination of the newly released 6-years datasets from both experiments find values consistent with no modulation at $0.0005 {\pm} 0.0019$ cpd/kg/keV in the 1-6 keV and $0.0027 {\pm} 0.0021$ cpd/kg/keV in the 2-6 keV energy regions with $4.68σ$ and $3.53σ$ respective exclusions of the DAMA/LIBRA signal.

astro-ph.IM↗

Cryogenic light detectors with thermal signal amplification for $0νββ$ search experiments

As a step towards the realization of cryogenic-detector experiments to search for neutrinoless double-beta decay (such as CROSS, BINGO, and CUPID), we investigated a batch of 10 Ge light detectors (LDs) assisted by Neganov-Trofimov-Luke (NTL) signal amplification. Each LD was assembled with a large cubic light-emitting crystal (45 mm side) using the recently developed CROSS mechanical structure. The detector array was operated at milli-Kelvin temperatures in a pulse-tube cryostat at the Canfranc underground laboratory in Spain. We achieved good performance with scintillating bolometers from CROSS, made of Li$_{2}$$^{100}$MoO$_4$ crystals and used as reference detectors of the setup, and with all LDs tested (except for a single device that encountered an electronics issue). No leakage current was observed for 8 LDs with an electrode bias up to 100 V. Operating the LDs at an 80 V electrode bias applied in parallel, we obtained a gain of around 9 in the signal-to-noise ratio of these devices, allowing us to achieve a baseline noise RMS of $O$(10 eV). Thanks to the strong current polarization of the temperature sensors, the time response of the devices was reduced to around half a millisecond in rise time. The achieved performance of the LDs was extrapolated via simulations of pile-up rejection capability for several configurations of the CUPID detector structure. Despite the sub-optimal noise conditions of the LDs (particularly at high frequencies), we demonstrated that the NTL technology provides a viable solution for background reduction in CUPID.

physics.ins-det↗

Micromegas with GEM preamplification for enhanced energy threshold in low-background gaseous time projection chambers

Background: we develop the concept of a Micromegas (MICRO-MEsh GAseous Structure) readout plane with an additional GEM (Gas Electron Multiplier) preamplification stage placed a few mm above it, to increase the maximum effective gain of the combined readout. We implement it and test it in realistic conditions for its application to low-background dark matter searches like the TREX-DM experiment. Methods: for this, we use a Micromegas of microbulk type, built with radiopure materials. A small test chamber allowing for systematic scanning of voltages and pressures is used. In addition, a TREX-DM full-scale set-up has also been built and tested, featuring a replica of the fully-patterned TREX-DM microbulk readout. Results: we report on GEM effective extra gain factors of about 90, 50 and 20 in 1, 4 and 10 bar of Ar-1%iC$_{4}$H$_{10}$. Conclusions: the results here obtained show promise to lower the threshold of the experiment down to 50 eV$_{ee}$, corresponding to substantially enhanced sensitivity to low-mass WIMPs (Weakly Interacting Massive Particles).

physics.ins-det↗

Precise $^{113}$Cd $β$ decay spectral shape measurement and interpretation in terms of possible $g_A$ quenching

Highly forbidden $β$ decays provide a sensitive test to nuclear models in a regime in which the decay goes through high spin-multipole states, similar to the neutrinoless double-$β$ decay process. There are only 3 nuclei ($^{50}$V, $^{113}$Cd, $^{115}$In) which undergo a $4^{\rm th}$ forbidden non-unique $β$ decay. In this work, we compare the experimental $^{113}$Cd spectrum to theoretical spectral shapes in the framework of the spectrum-shape method. We measured with high precision, with the lowest energy threshold and the best energy resolution ever, the $β$ spectrum of $^{113}$Cd embedded in a 0.43 kg CdWO$_4$ crystal, operated over 26 days as a bolometer at low temperature in the Canfranc underground laboratory (Spain). We performed a Bayesian fit of the experimental data to three nuclear models (IBFM-2, MQPM and NSM) allowing the reconstruction of the spectral shape as well as the half-life. The fit has two free parameters, one of which is the effective weak axial-vector coupling constant, $g_A^{\text{eff}}$, which resulted in $g_A^{\text{eff}}$ between 1.0 and 1.2, compatible with a possible quenching. Based on the fit, we measured the half-life of the $^{113}$Cd $β$ decay including systematic uncertainties as $7.73^{+0.60}_{-0.57} \times 10^{15}$ yr, in agreement with the previous experiments. These results represent a significant step towards a better understanding of low-energy nuclear processes.

nucl-ex↗

Development of large-volume $^{130}$TeO$_2$ bolometers for the CROSS $2β$ decay search experiment

We report on the development of thermal detectors based on large-size tellurium dioxide crystals (45x45x45 mm), containing tellurium enriched in $^{130}$Te to about 91%, for the CROSS double-beta decay experiment. A powder used for the crystals growth was additionally purified by the directional solidification method, resulting in the reduction of the concentration of impurities by a factor 10, to a few ppm of the total concentration of residual elements (the main impurity is Fe). The purest part of the ingot (the first ~200 mm, about 80% of the total length of the cylindrical part of the ingot) was determined by scanning segregation profiles of impurities and used for the $^{130}$TeO$_2$ powder production with no evidence of re-contamination. The crystal growth was verified with precursors produced from powder with natural Te isotopic composition, and two small-size (20x20x10 mm) samples were tested at a sea-level laboratory showing high bolometric and spectrometric performance together with acceptable $^{210}$Po content (below 10 mBq/kg). This growth method was then applied for the production of six large cubic $^{130}$TeO$_2$ crystals and 4 of them were taken randomly to be characterized at the Canfranc underground laboratory, in the CROSS-dedicated low-background cryogenic facility. Two $^{130}$TeO$_2$ samples were coated with a thin, $O$(100 nm), metal film in form of Al layer (on 4 sides) or AlPd grid (on a single side) to investigate the possibility to tag surface events by pulse-shape discrimination. Similarly to the small natural precursors, large-volume $^{130}$TeO$_2$ bolometers show high performance and even better internal purity ($^{210}$Po activity $\sim$ 1 mBq/kg, while activities of $^{228}$Th and $^{226}$Ra are below 0.01 mBq/kg), satisfying requirements for the CROSS and, potentially, next-generation experiments.

physics.ins-det↗

A novel mechanical design of a bolometric array for the CROSS double-beta decay experiment

The CROSS experiment will search for neutrinoless double-beta decay using a specific mechanical structure to hold thermal detectors. The design of the structure was tuned to minimize the background contribution, keeping an optimal detector performance. A single module of the structure holds two scintillating bolometers (with a crystal size of 45x45x45 mm and a Ge slab facing the crystal's upper side) in the Cu frame, allowing for a modular construction of a large-scale array. Two designs are released: the initial $Thick$ version contains around 15% of Cu over the crystal mass (lithium molybdate, LMO), while this ratio is reduced to ~6% in a finer ($Slim$) design. Both designs were tested extensively at aboveground (IJCLab, France) and underground (LSC, Spain) laboratories. In particular, at LSC we used a pulse-tube-based CROSS facility to operate a 6-crystal array of LMOs enriched/depleted in $^{100}$Mo. The tested LMOs show high spectrometric performance in both designs; notably, the measured energy resolution is 5--7 keV FWHM at 2615 keV $γ$s, nearby the Q-value of $^{100}$Mo (3034 keV). Due to the absence of a reflective cavity around LMOs, a low scintillation signal is detected by Ge bolometers: ~0.3 keV (150 photons) for 1-MeV $γ$($β$) LMO-event. Despite that, an acceptable separation between $α$ and $γ$($β$) events is achieved with most devices. The highest efficiency is reached with light detectors in the $Thick$ design thanks to a lower baseline noise width (0.05--0.09 keV RMS) when compared to that obtained in the $Slim$ version (0.10--0.35 keV RMS). Given the pivotal role of bolometric photodetectors for particle identification and random coincidences rejection, we will use the structure here described with upgraded light detectors, featuring thermal signal amplification via the Neganov-Trofimov-Luke effect, as also demonstrated in the present work.

physics.ins-det↗

BINGO innovative assembly for background reduction in bolometric $0νββ$ experiments

BINGO is a project aiming to set the grounds for large-scale bolometric neutrinoless double-beta-decay experiments capable of investigating the effective Majorana neutrino mass at a few meV level. It focuses on developing innovative technologies (a detector assembly, cryogenic photodetectors and active veto) to achieve a very low background index, of the order of $10^{-5}$ counts/(keV kg yr) in the region of interest. The BINGO demonstrator, called MINI-BINGO, is designed to investigate the promising double-beta-decay isotopes $^{100}$Mo and $^{130}$Te and it will be composed of Li$_2$MoO$_4$ and TeO$_2$ crystals coupled to bolometric light detectors and surrounded by a Bi$_4$Ge$_3$O$_{12}$-based veto. This will allow us to reject a significant background in bolometers caused by surface contamination from $α$-active radionuclides by means of light yield selection and to mitigate other sources of background, such as surface contamination from $β$-active radionuclides, external $γ$ radioactivity, and pile-up due to random coincidence of background events. This paper describes an R\&D program towards the BINGO goals, particularly focusing on the development of an innovative assembly designed to reduce the passive materials within the line of sight of the detectors, which is expected to be a dominant source of background in next-generation bolometric experiments. We present the performance of two prototype modules -- housing four cubic (4.5-cm side) Li$_2$MoO$_4$ crystals in total -- operated in the Canfranc underground laboratory in Spain within a facility developed for the CROSS double-beta-decay experiment.

physics.ins-det↗

Background discrimination with a Micromegas detector prototype and veto system for BabyIAXO

In this paper we present measurements performed with a Micromegas X-ray detector setup. The detector is a prototype in the context of the BabyIAXO helioscope, which is under construction to search for an emission of the hypothetical axion particle from the sun. An important component of such a helioscope is a low background X-ray detector with a high efficiency in the 1-10 keV energy range. The goal of the measurement was to study techniques for background discrimination. In addition to common techniques we used a multi-layer veto system designed to tag cosmogenic neutron background. Over an effective time of 52 days, a background level of $8.6 \times 10^{-7}\,\text{counts keV}^{-1}\,\text{cm}^{-2} \, \text{s}^{-1}$ was reached in a laboratory at above ground level. This is the lowest background level achieved at surface level. In this paper we present the experimental setup, show simulations of the neutron-induced background, and demonstrate the process to identify background signals in the data. Finally, prospects to reach lower background levels down to $10^{-7} \, \text{counts keV}^{-1} \, \text{cm}^{-2} \, \text{s}^{-1}$ will be discussed.

physics.ins-det↗

Neutron calibrations in dark matter searches: the ANAIS-112 case

ANAIS is a direct dark matter detection experiment whose goal is to confirm or refute in a model independent way the positive annual modulation signal claimed by DAMA/LIBRA. Consisting of 112.5 kg of NaI(Tl) scintillators, ANAIS-112 is taking data at the Canfranc Underground Laboratory in Spain since August, 2017. Results corresponding to the analysis of three years of data are compatible with the absence of modulation and incompatible with DAMA/LIBRA. However, testing this signal relies on the knowledge of the scintillation quenching factors (QF), which measure the relative efficiency for the conversion into light of the nuclear recoil energy with respect to the same energy deposited by electrons. Previous measurements of the QF in NaI(Tl) show a large dispersion. Consequently, in order to better understand the response of the ANAIS-112 detectors to nuclear recoils, a specific neutron calibration program has been developed. This program combines two different approaches: on the one hand, QF measurements were carried out in a monoenergetic neutron beam; on the other hand, the study presented here aims at the evaluation of the QF by exposing directly the ANAIS-112 crystals to neutrons from low activity $^{252}$Cf sources, placed outside the lead shielding. Comparison between these onsite neutron measurements and detailed GEANT4 simulations will be presented, confirming that this approach allows testing different QF models.

astro-ph.IM↗

Improving ANAIS-112 sensitivity to DAMA/LIBRA signal with machine learning techniques

The DAMA/LIBRA observation of an annual modulation in the detection rate compatible with that expected for dark matter particles from the galactic halo has accumulated evidence for more than twenty years. It is the only hint of a direct detection of the elusive dark matter, but it is in strong tension with the negative results of other very sensitive experiments, requiring ad-hoc scenarios to reconcile all the present experimental results. Testing the DAMA/LIBRA result using the same target material, NaI(Tl), removes the dependence on the particle and halo models and is the goal of the ANAIS-112 experiment, taking data at the Canfranc Underground Laboratory in Spain since August 2017 with 112.5 kg of NaI(Tl). At very low energies, the detection rate is dominated by non-bulk scintillation events and careful event selection is mandatory. This article summarizes the efforts devoted to better characterize and filter this contribution in ANAIS-112 data using a boosted decision tree (BDT), trained for this goal with high efficiency. We report on the selection of the training populations, the procedure to determine the optimal cut on the BDT parameter, the estimate of the efficiencies for the selection of bulk scintillation in the region of interest (ROI), and the evaluation of the performance of this analysis with respect to the previous filtering. The improvement achieved in background rejection in the ROI, but moreover, the increase in detection efficiency, push the ANAIS-112 sensitivity to test the DAMA/LIBRA annual modulation result around 3$σ$ with three-year exposure, being possible to reach 5$σ$ by extending the data taking for a few more years than the scheduled 5 years which were due in August 2022.

astro-ph.IM↗

Test of $^{116}$CdWO$_4$ and Li$_2$MoO$_4$ scintillating bolometers in the CROSS underground facility with upgraded detector suspension

In preparation to the CROSS $2β$ decay experiment, we installed a new detector suspension with magnetic dumping inside a pulse-tube cryostat of a dedicated low-background facility at the LSC (Spain). The suspension was tested with two scintillating bolometers based on large-volume 116CdWO4 (CWO-enr) and Li2MoO4 (LMO) crystals. The former, a reference device, was used for testing new noise conditions and for comparing bolometric performance of an advanced Li2MoO4 crystal developed in the framework of the CLYMENE project, in view of next-generation double-beta decay experiments like CUPID. We cooled down detectors to 15 mK and achieved high performance for all tested devices. In particular both CWO-enr and LMO bolometers demonstrated the energy resolution of 6 keV FWHM for the 2.6 MeV gamma quanta, among the best for thermal detectors based on such compounds. The baseline noise resolution (FWHM) of the CWO-enr detector was improved by 2 keV, compared to the best previous measurement of this detector in the CROSS facility, while the noise of the Ge-based optical bolometer was improved by a factor 2, to 100 eV FWHM. Despite of the evident progress in the improving of noise conditions of the set-up, we see high-frequency harmonics of a pulse-tube induced noise, suggesting a noise pick-up by cabling. Another Ge light detector was assisted with the signal amplification exploiting the Neganov-Trofimov-Luke effect, which allowed to reach 20 eV FWHM noise resolution by applying 60 V electrode bias. Highly-efficient particle identification was achieved with both detectors, despite a low scintillation efficiency of the LMO material. The radiopurity level of the LMO crystal is rather high; only traces of 210Po and 226Ra were detected (0.1 mBq/kg each), while the 228Th activity is expected to be at least an order of magnitude lower, as well as a 40K activity is found to be < 6 mBq/kg.

physics.ins-det↗

Ultra low background Micromegas detectors for BabyIAXO solar axion search

The International AXion Observatory (IAXO) is a large scale axion helioscope that will look for axions and axion-like particles produced in the Sun with unprecedented sensitivity. BabyIAXO is an intermediate experimental stage that will be hosted at DESY (Germany) and that will test all IAXO subsystems serving as a prototype for IAXO but at the same time as a fully-fledged helioscope with potential for discovery. One of the crucial components of the project is the ultra-low background X-ray detectors that will image the X-ray photons produced by axion conversion in the experiment. The baseline detection technology for this purpose are Micromegas (Microbulk) detectors. We will show the quest and the strategy to attain the very challenging levels of background targeted for BabyIAXO that need a multi-approach strategy coming from ground measurements, screening campaigns of components of the detector, underground measurements, background models, in-situ background measurements as well as powerful rejection algorithms. First results from the commissioning of the BabyIAXO prototype will be shown.

hep-ex↗